Hitachi L300P Series service manual Parts replacement

Page 34

5.6 Parts replacement

Inverter is consists from many electrical components. And inverter cannot work properly unless all of them works normal. Electrical components in following table are the components which may degrade according to the usage period.

HITACHI recommend to replace those electrical components periodically to avoid any expected failure caused by them.

Parts name

Recommended

Remarks

 

period for

 

 

replacement

 

Cooling fan

2 ~ 3 years

Replace with fresh one.

DC bus capacitors

5 years

Replace with fresh one. (Decide after inspection.)

Electrolytic capacitors

5 years

Replace with fresh one. (Decide after inspection.)

on PCB

 

 

Relays

-

Inspection in advance

(1) Cooling fan

Lifetime of the cooling fan depends on the usage condition, however it is normally around 35,000 hours. That means it is recommended to replace the cooling fan every 2 ~ 3 years in case the inverter operates continuously. Of course it should be replaced immediately in case the abnormality is found.

(How to remove cooling fan for mold case)

Remove terminal cover and front cover.

Reconfirm that the charge lamp is turned OFF.

ƒPush both side of the cooling fan holder plate and pull out like following figure. „ Remove the connector for fan connection.

ƒ

(How to fix cooling fan for mold case)

Pay attention to the direction of the cooling fan.

Connect the fan connector to J21 or J22 (depends on the model) on the power PCB.

ƒFix the cooling fan holder board to the inverter main body.

Fix the front cover and terminal cover.

Label side of

cooling fan

5- 5

Image 34
Contents Hitachi Inverter Revision History Table Inverter specification Investigation of the inverter Inverter specification 1 SJ300Function Mode Code 2nd motor Signal output mode Others Allowable motor selection 20-75.0kW 160kW User 2 L300P FE/-FU/-FR PID Terminal Meter C083 O2 adjustment 9999./1000-655310000-65530 U006 User6 selection Trouble Shooting Inverter trip contents, remedy, adviceIgbt Digital-input option board SJ-DG Option error Feed-back board SJ-FBDevice- Net option board SJ-DN Check of the trip monitor contents Check of the warning monitor contents Return to an initialization setup Factory-shipment state Debug Mode Monitor modeFunction mode USASetting procedure Setup of an inverterInitial cofiguration completion check procedure Model selection code C198 Code SJ300 L300P Control power supply Control signalMaintenance and Inspection Daily and annual maintenance Megger test How to check inverter & converter portion Parts replacement How to remove cooling fan for steel case How to fix DC bus capacitors for mold case Unit replacement English Internal block diagram SJ300-004-007LF Circuit Diagram SJ300-015 055LF Circuit Diagram SJ300-075-110LF , L300P-110-150LFR Circuit Diagram SJ300-150 220LF , L300P-185 300LFR Circuit Diagram SJ300-300LF, L300P-370LFR Circuit Diagram SJ300-370-450LF, L300P-450-550LFR Circuit Diagram SJ300-550LF,L300P-750LFR Circuit Diagram SJ300-007HF Circuit Diagram SJ300-015-055HF Circuit Diagram SJ300-075-110HF , L300P-110-150HFR Circuit Diagram SJ300-150 220HF , L300P-185 300HFR Circuit Diagram SJ300-300HF , L300P-370HFR Circuit Diagram SJ300-370- 550HF,L300P-450-750HFR Circuit Diagram DM Board SJ300-750-1320HF , L300P-900-1320HFR Circuit Diagram Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page SJ300/L300P Series Spare Parts List SJ3 CT PCB DM PCB NGMB25