Hitachi L300P Series service manual Pid

Page 15

Function Mode

 

 

Code

 

Function name

L300P Setting range

Initial data

N o t e

 

 

 

-FE/-FU/-FR

 

 

 

 

 

 

 

/ jump

 

A061

1s t

frequency upper limiter

0.00, 1s t frequency lower limiter-maximum frequency(Hz)

0.00

 

 

A261

2nd

frequency upper limiter

0.00, 2 nd frequency lower limiter-2ndsetting maximum

0.00

 

 

 

 

 

frequency(Hz)

 

 

 

 

 

 

 

limiter

 

A062

1s t

frequency lower limiter

0.00, start frequency-maximum frequency(Hz)

0.00

 

 

A262

2nd

frequency lower limiter

0.00, start frequency-2ndsetting maximum frequency(Hz)

0.00

 

 

 

 

lower

 

A063

Jump frequency1

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

A065

Jump frequency2

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

A064

Jump frequency Width 1

0.00-10.00(Hz)

0.50

 

 

 

 

 

 

 

 

andUpper

frequency

A066

Jump frequency Width 2

0.00-10.00(Hz)

0.50

 

A067

Jump frequency3

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

 

 

 

A068

Jump frequency Width 3

0.00-10.00(Hz)

0.50

 

 

 

A069

Acceleration stop frequency

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

A070

Acceleration stop time

0.00-60.0(s)

0.0

 

 

control

A071

PID selection

00(invalid)/01(valid)

00

 

 

A072

PID-P gain

0.2-5.0

1.0

 

 

 

A073

PID-I gain

0.0-3600.(s)

1.0

 

 

PID

A074

PID-D gain

0.00-100.0(s)

0.00

 

 

A075

PID scale

0.01-99.99

1.00

 

 

 

 

 

 

A076

PID feedback selection

00(feedback : OI)/01(feedback : O)

00

 

 

 

A081

AVR selection

00(ON always)/01(OFF always)/02(OFF on decelerating)

00/00/02

 

 

AVR

 

 

 

 

(230/400)

 

 

A082

Motor voltage selection

200/215/220/230/240, 380/400/415/440/460/480

(230/460)

 

 

 

 

 

 

 

(200/400)

 

 

 

A085

Operation mode selection

00(normal operation)/01(energy-saving operation)

00

 

 

function

A292

Energy-saving response-

0.01-99.99/100.0-999.9/1000.-3600.(s)

15.00

 

 

2nd

acceleration time2

 

 

 

A086

accuracy adjustment

0.0-100.0

50.0

 

 

 

A092

Acceleration time2

0.01-99.99/100.0-999.9/1000.-3600.(s)

15.00

 

 

adjustable

 

 

 

 

 

 

 

A294

2nd

stage adjustable

00(change with 2CH terminal)/01(change with setting)

00

 

 

 

A093

Deceleration time2

0.01-99.99/100.0-999.9/1000.-3600.(s)

15.00

 

 

 

A293

2nd

deceleration time2

0.01-99.99/100.0-999.9/1000.-3600.(s)

15.00

 

 

 

A094

2nd stage adjustable selection

00(change with 2CH terminal)/01(change with setting)

00

 

 

mode/

 

selection(2nd motor)

 

 

 

 

A095

2nd

acceleration

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

2nd

acceleration frequency

 

 

Operation

A295

frequency(2nd motor)

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

 

 

 

 

A096

2nd

deceleration frequency

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

 

 

 

A296

2nd

deceleration frequency

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

(2nd motor)

 

 

 

 

 

 

 

 

 

A097

Acceleration pattern selection

00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)

00

 

 

 

A098

Deceleration pattern selection

00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)

00

 

frequencyExternal

 

A101

OI start

0.00-99.99/100.0-400.0(Hz)

0.00

 

adjustment

A102

OI end

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

 

 

 

A103

OI start rate

0.-100. ( %)

20.

 

 

 

A104

OI end rate

0.-100. ( %)

100.

 

 

 

A105

OI start selection

00(external start frequency)/01(0Hz)

01

 

 

 

A111

O2 start

-400.--100./-99.9-0.00-99.9/100.-400.(Hz)

0.00

 

 

 

A112

O2 end

-400.--100./-99.9-0.00-99.9/100.-400.(Hz)

0.00

 

 

 

A113

O2 start rate

-100. - 100. (%)

-100.

 

 

 

A114

O2 end rate

-100. - 100. (%)

100.

 

Accel

Decel

A131

Acceleration curve constant

01(small swelling)-10(large swelling)

02

 

A132

Deceleration curve constant

01(small swelling-10(large swelling)

02

 

 

 

b001

Retry selection

00(trip)/01(0Hz start)/02(start after equal frequency)/

00

 

failure

 

03(trip after equaling frequency and deceleration stop)

 

 

 

 

 

 

 

 

b002

Allowable under-voltage

0.3-1.0(s)

1.0

 

 

 

 

 

 

power failure time

 

power

 

 

 

 

 

 

b003

Retry wait time

0.3-100.(s)

1.0

 

 

 

 

 

 

 

Instantaneous power-

00(invalid/01(valid)/

 

 

Instantaneous

 

b004

failure/under-voltage trip

00

 

restart

00(invalid)/01(valid)

 

b006

Open-phase selection

00

 

 

 

 

during stop

02(invalid during stop and deceleration by stop command)

 

 

 

 

 

Instantaneous power-

 

 

 

 

 

b005

failure/under-voltage

00(16 times)/01(free)

00

 

 

 

 

retry time selection

 

 

 

 

 

 

 

 

 

 

 

 

b007

Frequency setting to match

0.00-99.99/100.0-400.0(Hz)

0.00

 

 

 

b012

Electronic thermal level

0.2*constant current-1.20*constant current(A)

Rated

 

 

 

Current of

 

 

 

 

 

 

 

inverter

 

 

 

 

Electronic thermal level

 

Rated

 

 

 

b212

0.2*constant current-1.20*constant current(A)

Current of

 

 

 

(2nd motor)

 

 

 

 

 

 

 

inverter

 

Electronic thermal

b013

Electronic thermal

00/(reduced characteristic)01(constant torque characteristic)/

01/01/00

 

characteristic selection

02(free setting)

 

 

 

 

 

Electronic thermal

00/(reduced characteristic)01(constant torque characteristic)/

 

 

b213

characteristic selection

01/01/00

 

02(free setting)

 

 

(2nd motor)

 

 

 

 

 

 

b015

Free electronic thermal

0.-400.(Hz)

0.

 

frequency 1

 

 

 

 

 

b016

Free electronic thermal

0.0-1000.(A)

0.0

 

current 1

 

 

 

 

 

b017

Free electronic thermal

0.-400.(Hz)

0.

 

frequency 2

 

 

 

 

 

b018

Free electronic thermal

0.0-1000. (A)

0.0

 

current 2

 

 

 

 

 

b019

Free electronic thermal

0.-400.(Hz)

0.

 

frequency 3

 

 

 

 

 

b020

Free electronic thermal

0.0-1000.(A)

0.0

 

current 3

 

 

 

 

 

1- 12

Image 15
Contents Hitachi Inverter Revision History Table Inverter specification Investigation of the inverter 1 SJ300 Inverter specificationFunction Mode Code 2nd motor Signal output mode Others Allowable motor selection 20-75.0kW 160kW User 2 L300P FE/-FU/-FR PID Terminal Meter C083 O2 adjustment 9999./1000-655310000-65530 U006 User6 selection Inverter trip contents, remedy, advice Trouble ShootingIgbt Option error Feed-back board SJ-FB Digital-input option board SJ-DGDevice- Net option board SJ-DN Check of the trip monitor contents Check of the warning monitor contents Return to an initialization setup Factory-shipment state Monitor mode Debug ModeUSA Function modeSetup of an inverter Setting procedureInitial cofiguration completion check procedure Model selection code C198 Code SJ300 L300P Control signal Control power supplyMaintenance and Inspection Daily and annual maintenance Megger test How to check inverter & converter portion Parts replacement How to remove cooling fan for steel case How to fix DC bus capacitors for mold case Unit replacement English Internal block diagram SJ300-004-007LF Circuit Diagram SJ300-015 055LF Circuit Diagram SJ300-075-110LF , L300P-110-150LFR Circuit Diagram SJ300-150 220LF , L300P-185 300LFR Circuit Diagram SJ300-300LF, L300P-370LFR Circuit Diagram SJ300-370-450LF, L300P-450-550LFR Circuit Diagram SJ300-550LF,L300P-750LFR Circuit Diagram SJ300-007HF Circuit Diagram SJ300-015-055HF Circuit Diagram SJ300-075-110HF , L300P-110-150HFR Circuit Diagram SJ300-150 220HF , L300P-185 300HFR Circuit Diagram SJ300-300HF , L300P-370HFR Circuit Diagram SJ300-370- 550HF,L300P-450-750HFR Circuit Diagram DM Board SJ300-750-1320HF , L300P-900-1320HFR Circuit Diagram Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page SJ300/L300P Series Spare Parts List SJ3 CT PCB DM PCB NGMB25