3.1.12.1.3 AMPS idling plus ½ the value of the charging current; e.g. when charging 40 AMPS the line current is 23 AMPS (Note: nominal values, line voltage and frequency dependent).
3.2DISCHARGE
3.2.1.CONTROL: Transistors, air cooled.
3.2.2.MAXIMUM CURRENT:
3.2.2.1.60 AMPS. Total power dissipation must not exceed 1.2KW (1200 watts, the product of battery voltage and battery current).
3.2.2.2.NOTE: Discharge current is automatically limited to 30 AMPS for battery voltages in excess of 32 VOLTS. A current fault will be generated if attempting to discharge at more than 30 AMPS.
3.2.3.MINIMUM INCREMENT:
3.2.3.1.0.1 AMP.
3.2.4.ACCURACY and STABILITY of settings:
3.2.4.1.±1% of reading, ±0.1AMP.
3.2.5.MODES:
3.2.5.1.Analysis (automatic
3.2.5.2.Deep cycle (full discharge).