Omega Engineering FP-6000 manual Using the Hot-Tap Installation Tool

Page 18

Using the Hot-Tap Installation Tool

The Hot-Tap installation tool helps to lower the sensor into place against the pressure in the pipe.

1.Thread protector plate hex nuts onto each of the three threaded rods. Adjust each hex to a height of approximately 1 in. (25 mm) from the top of each rod. Remove the black plastic cable grom- met in top of sensor with a screwdriver. Slide the grommet up the cable away from sensor.

2.Position the installation tool bearing plate by rotating it so that it is approximately 2 inches away from the swivel mount. Mount the installation tool by placing the threaded rods through the holes in the tool's bearing plate, resting the bearing plate on top of the protector plate hex nuts. Make sure the swivel mount's ears are mounted between the threaded rods (not over the rods). Install the bearing plate cap nuts. Tighten the bearing plate cap nuts to secure the installation tool in place.

protector plate cap nuts

1.0 in.

(25 mm)

cable grommit

Protector plate removed during sensor installation

Protector plate hex nut (3/16 x 1/4-20)

cap nuts

protector plate

hex nuts

sensor

cable

installation tool threaded shaft

bearing plate

swivel mount w/cable port

sensor flange

sensor body

12

Image 18
Contents User’s Guide Servicing North America For immediate technical or application assistanceServicing Europe Table of Contents Page Important Safety Information Warranty Record Type Omega FP-6000 SeriesChapter Introduction DescriptionTheory of Operation Chapter Installation and Wiring Location of FittingSensor Position Sensor Wiring +30Hardware, Hot-Tap Sensor Standard Fitting InstallationHardware, Standard Sensor 11/4 in mm diameter drill Pipe thread sealant Tape measureHot-Tap Fitting Installation Remove brass sensor nut from sensorThread brass sensor nut into pipe fitting Calculating the H Dimension Wall ThicknessRecord your pipes H dimension for future reference Hot-Tap Sensor = 15.00 pipe wall thickness 0.10 X I.DStandard Installation Sensor flange Alignment rod Direction of flow Hot-Tap Installation StepThread one jam nut and lower hex nut onto Make sure the bleed valve is closed full clockwise position Direction of flowUsing the Hot-Tap Installation Tool Protector plate Installation tool shaft Upper hex nuts Hot-Tap Sensor Removal ChapterStandard Sensor Removal Into the port to prevent damageCap nuts Installation tool Chapter Maintenance and Replacement Parts MaintenanceReplacement Parts Rotor Replacement Procedure Wrought Steel Pipe Per Ansi DimensionsDimensions for Standard Sensors Conversion Stainless Steel Pipe Per Ansi B36.19 Mm = inchesDimensions for Hot-Tap Sensors Factors Stainless Steel GPM/HZ LPM/HZFactors Wrought Steel Factors Plastic Pipe GPM/HZ LPM/HZSpecifications General DataSpecifications WARRANTY/DISCLAIMER OMEGA…Of Course