Maintenance and Replacement Parts

5.1 Maintenance

All versions of the FP-6000 series sensor require little or no maintenance, with the exception of an occasional sensor/paddlewheel cleaning.

5.2 Replacement Parts

(Standard version)

1.Standard sensor assembly FP-6000, -6001

2.Rotor kit (bearings, shaft, retainers, and rotor included), see table below

FP52509-1 kit with stainless steel shaft

FP52509-2 kit with Tungsten Carbide shaft

3. Instruction manual

M-2973

 

Rotor Kit

FP52509-1 Rotor Kit

retainer

retainer

• Retainer material: 316 stainless steel

 

rotor shaft

• Rotor shaft material: 316 stainless steel

 

• Bearing material: Fluoroloy B

 

 

 

 

• Rotor material: CD4MCu stainless steel

bearing

bearing

rotor

FP52509-2 Rotor Kit

 

• Retainer material: 316 stainless steel

 

• Rotor shaft material: Tungsten Carbide

Refer to rotor replacement

Bearing material: Fluoroloy B

instructions, pg# 17

Rotor material: CD4MCu stainless steel

(Hot-Tap version)

4.Hot-Tap sensor assembly FP-6000, -6001

5.Rotor kit (bearings, shaft, retainers, and rotor included), see table above

FP52509-1 kit with stainless steel shaft

FP52509-2 kit with Tungsten Carbide shaft

6. Instruction manual

M-2973

16

Image 22 Contents
User’s Guide For immediate technical or application assistance Servicing North AmericaServicing Europe Table of Contents Page Important Safety Information Warranty Record Type Omega FP-6000 SeriesDescription Chapter IntroductionTheory of Operation Location of Fitting Chapter Installation and WiringSensor Position Sensor Wiring +30Hardware, Hot-Tap Sensor Standard Fitting InstallationHardware, Standard Sensor 11/4 in mm diameter drill Pipe thread sealant Tape measureRemove brass sensor nut from sensor Hot-Tap Fitting InstallationThread brass sensor nut into pipe fitting Calculating the H Dimension Wall ThicknessRecord your pipes H dimension for future reference Hot-Tap Sensor = 15.00 pipe wall thickness 0.10 X I.DStandard Installation Sensor flange Alignment rod Direction of flow Step Hot-Tap InstallationThread one jam nut and lower hex nut onto Make sure the bleed valve is closed full clockwise position Direction of flowUsing the Hot-Tap Installation Tool Protector plate Installation tool shaft Upper hex nuts Hot-Tap Sensor Removal ChapterStandard Sensor Removal Into the port to prevent damageCap nuts Installation tool Maintenance Chapter Maintenance and Replacement PartsReplacement Parts Rotor Replacement Procedure Wrought Steel Pipe Per Ansi DimensionsDimensions for Standard Sensors Conversion Stainless Steel Pipe Per Ansi B36.19 Mm = inchesDimensions for Hot-Tap Sensors Factors Stainless Steel GPM/HZ LPM/HZFactors Wrought Steel Factors Plastic Pipe GPM/HZ LPM/HZSpecifications General DataSpecifications WARRANTY/DISCLAIMER OMEGA…Of Course