Standard Sensor
H = 5.95 - pipe wall thickness - (0.10 X I.D.)
Example:
3.0inch schedule 80 wrought steel; Wall thickness= 0.3 in.
Inside diameter = 2.9 in.
H = 5.95 - 0.3 - (0.10 X 2.9)
H = 5.36 in. | sensor flange |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| "H" |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| pipe side view |
|
|
|
|
|
|
|
|
|
Record your pipes "H" dimension for future reference:
H= _________________
alignment rod
process pipe
direction of flow
Hot-Tap Sensor
H = 15.00 - pipe wall thickness - (0.10 X I.D.)
protector plate
Example:
10 inch schedule 40 wrought steel; Wall thickness= 0.365 in.
Inside diameter = 10.02 in.
H = 15.00 - 0.365 - (0.10 X 10.02) H = 13.633 in.
Record your pipes "H" dimension for future reference:
"H"
direction of flow
alignment rod
H= _________________ | process pipe (side view) |
7