Omega Engineering FP-6000 manual Dimensions for Hot-Tap Sensors

Page 25

H Dimensions for Hot-Tap Sensors

H Dimensions

Wrought Steel Pipe Per ANSI 36.10

 

 

 

 

 

 

 

NPS

SCH 40

SCH 80

STD

XS

1-1/2 in.

14.694 in.

14.650 in.

14.694 in.

14.650 in.

2 in.

14.639 in.

14.588 in.

14.639 in.

14.588 in.

2-1/2 in.

14.550 in.

14.492 in.

14.550 in.

14.492 in.

3 in.

14.477 in.

14.410 in.

14.477 in.

14.410 in.

3-1/2 in.

14.419 in.

14.346 in.

14.419 in.

14.346 in.

4 in.

14.360 in.

14.280 in.

14.360 in.

14.280 in.

5 in.

14.237 in.

14.144 in.

14.237 in.

14.144 in.

6 in.

14.144 in.

13.992 in.

14.144 in.

13.992 in.

8 in.

13.880 in.

13.738 in.

13.880 in.

13.738 in.

10 in.

13.633 in.

13.450 in.

13.633 in.

13.525 in.

12 in.

13.400 in.

13.175 in.

13.425 in.

13.325 in.

14 in.

13.250 in.

13.000 in.

13.300 in.

13.200 in.

16 in.

13.000 in.

12.725 in.

13.100 in.

13.000 in.

18 in.

12.750 in.

12.450 in.

12.900 in.

12.800 in.

20 in.

12.525 in.

12.175 in.

12.700 in.

12.600 in.

22 in.

*

11.900 in.

12.500 in.

12.400 in.

24 in.

12.050 in.

11.625 in.

12.300 in.

12.200 in.

 

 

 

 

 

 

 

 

Conversion:

 

Stainless Steel Pipe Per ANSI B36.19

mm = inches (25.4)

 

 

 

 

 

NPS

SCH 5S

SCH 10S

SCH 40S

SCH 80S

1-1/2 in.

14.758 in.

14.723 in.

14.694 in.

14.650 in.

2 in.

14.711 in.

14.675 in.

14.639 in.

14.588 in.

2-1/2 in.

14.646 in.

14.617 in.

14.550 in.

14.492 in.

3 in.

14.584 in.

14.554 in.

14.477 in.

14.410 in.

3-1/2 in.

14.534 in.

14.504 in.

14.419 in.

14.346 in.

4 in.

14.484 in.

14.454 in.

14.360 in.

14.280 in.

5 in.

14.357 in.

14.337 in.

14.237 in.

14.144 in.

6 in.

14.250 in.

14.230 in.

14.144 in.

13.992 in.

8 in.

14.050 in.

14.019 in.

13.880 in.

13.738 in.

10 in.

13.818 in.

13.793 in.

13.633 in.

13.525 in.

12 in.

13.600 in.

13.581 in.

13.425 in.

13.325 in.

14 in.

13.475 in.

13.450 in.

*

*

16 in.

13.268 in.

13.250 in.

*

*

18 in.

13.068 in.

13.050 in.

*

*

20 in.

12.850 in.

12.826 in.

*

*

22 in.

12.650 in.

12.626 in.

*

*

24 in.

12.426 in.

12.400 in.

*

*

(*) represents values currently unavailable

 

 

 

 

 

 

 

19

Image 25
Contents User’s Guide For immediate technical or application assistance Servicing North AmericaServicing Europe Table of Contents Page Important Safety Information Type Omega FP-6000 Series Warranty RecordDescription Chapter IntroductionTheory of Operation Location of Fitting Chapter Installation and WiringSensor Position +30 Sensor WiringHardware, Standard Sensor Standard Fitting InstallationHardware, Hot-Tap Sensor 11/4 in mm diameter drill Pipe thread sealant Tape measureRemove brass sensor nut from sensor Hot-Tap Fitting InstallationThread brass sensor nut into pipe fitting Wall Thickness Calculating the H DimensionHot-Tap Sensor = 15.00 pipe wall thickness 0.10 X I.D Record your pipes H dimension for future referenceStandard Installation Sensor flange Alignment rod Direction of flow Step Hot-Tap InstallationThread one jam nut and lower hex nut onto Direction of flow Make sure the bleed valve is closed full clockwise positionUsing the Hot-Tap Installation Tool Protector plate Installation tool shaft Upper hex nuts Standard Sensor Removal ChapterHot-Tap Sensor Removal Into the port to prevent damageCap nuts Installation tool Maintenance Chapter Maintenance and Replacement PartsReplacement Parts Rotor Replacement Procedure Dimensions for Standard Sensors DimensionsWrought Steel Pipe Per Ansi Conversion Stainless Steel Pipe Per Ansi B36.19 Mm = inchesDimensions for Hot-Tap Sensors GPM/HZ LPM/HZ Factors Stainless SteelFactors Wrought Steel GPM/HZ LPM/HZ Factors Plastic PipeGeneral Data SpecificationsSpecifications WARRANTY/DISCLAIMER OMEGA…Of Course