266XLCompressor/Gate

IEC - AC Power cord receptacle

7

Plug the AC power cord (supplied) into the 266XL. Plug the other end into a standard wall receptacle. Take care to route power cables away from audio lines. Note that the 266XL does not have a power switch. It is recommended that the 266XL be ÒOnÓ at all times. Power consumption is low. If you do not plan to use the 266XL for an extended period of time, unplug it.

WARNING: Be sure to verify your actual line voltage is the same as the voltage level printed below the AC power receptacle. Connection to an inappropriate power source may result in extensive damage which is not covered by the warranty.

Caution: Never remove the cover. There are no user-serviceable parts inside.

CONNECTING THE 266XL TO YOUR SYSTEM

The 266XL can be used with any line-level device. Some common examples include mixing consoles, electronic musical instruments, patch bays, and signal processors. For all connections, refer to the following steps:

Turn Off all equipment before making any connections.

Mount the 266XL in a 1U rack space (optional).

The 266XL requires one rack space (height) and 1 rack space (width). It can be mounted above or below anything that doesn't generate excessive heat, since it requires no special ventilation. Ambient temperatures should not exceed 113¼F (45¼C) when equipment is powered.

Make connections via 1/4Ó phone or XLR jacks according to your requirements. Typical patch points include: a mixer's channel or subgroup inserts when using the 266XL on individual instruments or tracks; the mixer's main outputs when mixing; an instrument preamp's effects loop when using the 266XL for guitar or bass; main outs of a submixer (i.e., keyboard mixer) as the signal is sent to main mixer; between a DAT's output and an analog cassette input. When using a chain of processors, the 266XL may be placed either before or after effects or dynamics processors. We rec- ommend you use common sense and experiment with different setups to see which one provides the best results for your needs.

Connect the AC power cord (shipped with the unit) to the 266XL's rear panel

POWER connector and an appropriate AC power source to turn the unit ON.

Image 9
Contents 6 X L C o m p r e s s o r / G a t e Mains Plug Warning English Contents Manual ContentsIntroduction Common Compressor ApplicationsCommon Gating Applications Bypass Switch and LED Stereo Couple Switch and LEDOperating Controls Gain Reduction dB MeterCompressor Section OVEREASY¨ SwitchCompressor Threshold Control and LEDs BELOW/OVEREASY/ABOVE Compressor Ratio ControlEXPANDER/GATE Section Auto SwitchCompressor Attack and Release Control Expander/Gate Threshold Control and LEDs BELOW/ABOVEExpander/Gate Ratio Control Operating Level SwitchInput Jacks Channel 1 Output Jacks Channel 1IEC AC Power cord receptacle Connecting the 266XL to Your SystemRegistration Card and User Feedback Technical Support and Factory ServiceFrançais Instructions DE Securite Table DES Matieres Applications courantes du Gate Applications courantes de la compressionTouche et Led Bypass Touche et Led Stereo CoupleAfficheur Gain Reduction dB Output Gain dBTouche OVEREASY¨ Section CompresseurSeuil de compression Threshold et LEDs BELOW/OVEREASY/ABOVE Bouton Ratio du compresseurRŽglage des Temps Dattaque et de Relachement Section EXPANSEUR/GATETouche Automatique Bouton Threshold et Leds BELOW/ABOVE de lexpanseur/GateSorties Jack Voies 1 et ENTRƒES Jack voies 1 etTouche Operating Level Jack dinsert Side ChainConnexion DU 266XL a Votre Systeme Connecteur dalimentationConnexions ˆ vos Žquipements ˆ lÕaide de jacks 6.35 ou XLR Carte DE Garantie Deutsch Warnung Inhalt Einleitung †bliche Kompressor-Anwendungen†bliche Gate-Anwendungen Stereo COUPLE-Taste und -LED BedienelementeBYPASS-Taste und -LED Gain Reduction dB-AnzeigeOVEREASY¨-Taste KOMPRESSOR-SEKTIONCompressor THRESHOLD-Regler und -LEDs -/0/+ Compressor RATIO-ReglerCompressor ATTACK- und RELEASE-Regler EXPANDER/GATE-SEKTIONAUTO-Taste EPANDER/GATE THRESHOLD-Regler und -LEDs -/+Input Eingangsbuchsen Channel 1 und Channel EXPANDER/GATE RATIO-ReglerOutput Ausgangsbuchsen Channel 1 und Channel Operating LEVEL-TasteService UND Kundendienst Anschliessen DES DBX 266XL AN Ihre AnlageIEC-KaltgerŠtebuchse REGISTRIERUNGS- UND Antwortkarte Español Atencion Contenido DEL Manual Introduccion Aplicaciones comunes del compresorAplicaciones comunes de compuertas Conmutador y LED Stereo Couple ControlesConmutador y LED Bypass Medidor Gain Reduction dBConmutador OVEREASY¨ Seccion CompressorControl Compressor Threshold y LEDs -/0/+ Control Compressor RatioControles Compressor Attack y Release Seccion EXPANDER/GATEConmutador Auto Control EXPANDER/GATE Threshold y LEDs -/+Jacks de entrada Input Canal 1 y Control EXPANDER/GATE RatioJacks de salidaOUTPUT Canal 1 y Conmutador Operating LevelTomacorriente CA tipo IEC Apoyo Tecnico Y Servicio DE FabricaTarjeta DE Registro Y Reacciones DE LOS Usuarios Threshold 6 X L C o m p r e s s o r / G a t e 266XL Harman International Company