Baldor MN735 manual Section Start-Up and Operation, Keypad Description

Page 30

Section 4

Start–Up and Operation

Keypad Description

Figure 4-1 Keypad Description

Display

 

Local

Local

 

Run

Stop

 

 

Programming Keys

Key

Operation

Description

 

Escape

Navigation – Displays the previous level’s menu

 

 

Parameter – Returns to the parameter list

 

 

Trip Acknowledge – Acknowledges displayed Trip or Error

 

 

message

 

Menu

Navigation – Displays the next menu level, or the first parameter

 

 

of the current Menu

 

 

Parameter – Moves cursor to the left when the parameter is

 

 

adjustable

 

Increment

Navigation – Move upwards through the menu system

 

 

Parameter – Increase value of the displayed parameter

 

 

Local Mode – Increase value of the local setpoint

 

Decrement

Navigation – Move down through the menu system

 

 

Parameter – Decrease value of the displayed parameter

 

 

Local Mode – Decrease value of the local setpoint

 

Run

Local Mode – Run the drive

 

Stop

Local Mode – Stops the drive. Trip Reset in all modes

 

 

Navigation – Press and hold to toggle between Local and

 

 

Remote Control modes (refer to Special Menu Features)

The keypad provides local control and monitoring of the Inverter. Remove it by simply pulling it from the drive. To install it, push it back into place.

MN735

Start–Up and Operation 4–1

Image 30
Contents Series 35D Inverter Control MN735Table of Contents Appendix a Appendix BPower and Motor Connections Section Quick StartRemote Mode Size 1 and 3 Terminal StripsPower Connection Descriptions Thermistor Connection to motor thermistorAnalog/Digital Signal Descriptions Terminal Signal Name Description RangeLimited Warranty Section General InformationProduct Notice Intended use Could result in damage to propertyOn next Precautions To prevent equipment damage, be certain that the input power Section Receiving & Installation Receiving & InspectionLocation and Mounting Watts Loss Ratings Catalog No Output Current Inverter SizesPower Conditioning Input Power ConditioningUngrounded Distribution System Impedance + Unshielded and Shielded Couplings Clamp TerminalWire Size AWG MM2Power Connection Descriptions Power and Ground Connections Size 2 Shown Resistance thresholds are Rising temperature trip resistance One control to PE Receiving & Installation MN735 External Brake Resistor Keypad Mode Keypad Connection DiagramStandard Run 3 Wire Mode Standard Run Connection DiagramSpeed 2 Wire Mode Related Parameters10 Epot Connection Diagram 11 Epot Connection Diagram PID 2 Wire Mode 12 PID Connection DiagramReceiving & Installation MN735 Section Start-Up and Operation Keypad DescriptionDiagnostics Menu DisplayDrive Status Indications shown on keypad Menu Level Reset to Factory Settings 2 button Reset Select Local or RemoteRemote to Local Password Protection Quick Application SelectionDisplay Parameter Description Range Factory Setting Parameter DefinitionsDisplay Parameter Description Range PI P Gain Analog Output Relay Invert =FALSE =TRUE Method for Setting-up the PI Gains Proportional Gain P501Integral P502 Power Dependent Parameters Inverter Size Factory Setting CurrentMaterial Recycle Disposal Routine MaintenanceSaving Your Application Data PackagingSection Troubleshooting Reset a TripTrips General Failures DC Link RippleSection Specifications & Product Data General SpecificationsControl Specifications Keypad DisplayAnalog Inputs Relay Output Analog OutputsDigital Inputs Ratings CatalogDimensions 460VAC 3 Phase Controls Size 2 and 3 460VAC Size 1 and 2 230VAC 1 PhaseSize 3 230VAC 3 Phase Appendix a Dynamic BrakeTable A-1 External Brake Resistor Selection CE Declaration of Conformity Wiring of Shielded Screened CablesAppendix B CE Guidelines EMC Conformity and CE MarkingEMC Wiring Technique CabinetEMC Installation Instructions Cable Screens GroundingInput Signal Cable Grounding Date 1/5/02 EC Declarations of Conformity Standard EMC DirectiveTion CE Guidelines MN735 Box Ft. Smith, AR 479 Fax 479  Baldor Electric Company MN735 02 C&J