Baldor MN735 manual General Failures, DC Link Ripple

Page 45

Display

Trip Message and Meaning

Possible Reason for Trip

 

 

Motor loading too great

 

 

FIXED BOOST level set too high

 

DC LINK RIPPLE

Supply imbalance in a 3–phase system

 

A dc link ripple alert

Poor supply regulation in a 1–phase system

 

CURRENT LIMIT

See OVERCURRENT above

 

Software overcurrent trip

 

 

TERMINAL 3 OVERLOAD

AIN2 overload – overcurrent applied in Current

 

 

mode

 

TERMINAL 4 OVERLOAD

+10V REF overload warning – 10mA maximum

 

TERMINAL 5 OVERLOAD

AOUT overload – 10mA maximum

 

TERMINAL 9 OVERLOAD

DIN3 overload – 20mA maximum

 

TERMINAL 10 OVERLOAD

DOUT2 overload – 20mA maximum

 

Product Code Error

Switch unit off/on. If persistent, return unit to

 

 

factory

 

Calibration Data Error

Switch unit off/on. If persistent, return unit to

 

 

factory

 

Configuration Data Error

 

General Failures

Problem

Possible Cause

Remedy

Inverter will not power–up

Fuse blown

Check supply details, fit correct fuse.

 

 

Check Product Code against Model

 

 

No.

 

Faulty cabling

Check all connections are

 

 

correct/secure.

 

 

Check cable continuity

 

 

 

Inverter fuse keeps blowing

Faulty cabling or

Check for problem and rectify before

 

connections wrong

replacing with correct fuse

 

Faulty Inverter

Contact Eurotherm Drives

 

 

 

Cannot obtain power–on

Incorrect or no supply

Check supply details

state

available

 

 

 

 

Motor will not run at

Motor jammed

Stop the Inverter and clear the jam

switch–on

 

 

 

 

 

Motor runs and stops

Motor becomes jammed

Stop the Inverter and clear the jam

 

 

 

 

Open circuit speed reference

Check terminal

 

potentiometer

 

 

 

 

5–2 Troubleshooting

MN735

Image 45
Contents MN735 Series 35D Inverter ControlTable of Contents Appendix B Appendix aSection Quick Start Power and Motor ConnectionsSize 1 and 3 Terminal Strips Remote ModeThermistor Connection to motor thermistor Power Connection DescriptionsTerminal Signal Name Description Range Analog/Digital Signal DescriptionsSection General Information Limited WarrantyProduct Notice Intended use Could result in damage to propertyOn next Precautions To prevent equipment damage, be certain that the input power Section Receiving & Installation Receiving & InspectionLocation and Mounting Inverter Sizes Watts Loss Ratings Catalog No Output CurrentPower Conditioning Input Power ConditioningUngrounded Distribution System Impedance + Clamp Terminal Unshielded and Shielded CouplingsAWG MM2 Wire SizePower Connection Descriptions Power and Ground Connections Size 2 Shown Resistance thresholds are Rising temperature trip resistance One control to PE Receiving & Installation MN735 External Brake Resistor Keypad Connection Diagram Keypad ModeStandard Run Connection Diagram Standard Run 3 Wire ModeRelated Parameters Speed 2 Wire Mode10 Epot Connection Diagram 11 Epot Connection Diagram 12 PID Connection Diagram PID 2 Wire ModeReceiving & Installation MN735 Keypad Description Section Start-Up and OperationDiagnostics Menu DisplayDrive Status Indications shown on keypad Menu Level Reset to Factory Settings 2 button Reset Select Local or RemoteRemote to Local Quick Application Selection Password ProtectionParameter Definitions Display Parameter Description Range Factory SettingDisplay Parameter Description Range PI P Gain Analog Output Relay Invert =FALSE =TRUE Method for Setting-up the PI Gains Proportional Gain P501Integral P502 Current Power Dependent Parameters Inverter Size Factory SettingSaving Your Application Data Routine MaintenanceMaterial Recycle Disposal PackagingSection Troubleshooting Reset a TripTrips DC Link Ripple General FailuresGeneral Specifications Section Specifications & Product DataControl Specifications Keypad DisplayAnalog Inputs Digital Inputs Analog OutputsRelay Output Ratings CatalogDimensions Size 3 230VAC 3 Phase Size 1 and 2 230VAC 1 Phase460VAC 3 Phase Controls Size 2 and 3 460VAC Appendix a Dynamic BrakeTable A-1 External Brake Resistor Selection Appendix B CE Guidelines Wiring of Shielded Screened CablesCE Declaration of Conformity EMC Conformity and CE MarkingCabinet EMC Wiring TechniqueCable Screens Grounding EMC Installation InstructionsInput Signal Cable Grounding Date 1/5/02 EC Declarations of Conformity Standard EMC DirectiveTion CE Guidelines MN735  Baldor Electric Company MN735 02 C&J Box Ft. Smith, AR 479 Fax 479