Baldor MN735 manual Section Specifications & Product Data, General Specifications

Page 46

Section 6

Specifications & Product Data

General Specifications:

 

 

 

 

 

Enclosure:

 

Open Type (Protected Chassis)

 

Enclosure rating:

Europe

IP20

 

 

 

North America / Canada

Chassis/IP20

 

 

Mounting method:

 

Panel mount or DIN rail mounting (35mm).

Enclosure emissions:

 

Enclosure provides 15dB attenuation to radiated

 

 

emissions between 30–100MHz. It must also

 

 

require a security tool for opening.

 

Horsepower:

 

1/3–2 HP

@ 230VAC, 1 Phase

 

 

 

3–5 HP

@ 230VAC, 3 Phase

 

 

 

1/2–10 HP @ 460VAC, 3 Phase

 

Voltage Range: 230 VAC Models

198-264 VAC 1φ

60 Hz / 198-264 VAC 1φ

50 Hz

460 VAC Models

198-264 VAC 3φ

60 Hz / 198-264 VAC 3φ

50 Hz

 

 

342-506 VAC 3φ

60 Hz / 342-506 VAC 3φ

50 Hz

Input Line Impedance:

 

1%

 

 

 

Service Factor:

 

1.0

 

 

 

Duty:

 

Continuous

 

 

 

Ambient Operating Temperature:

0 to +40 ° C with linear derating to 50 ° C

 

 

 

(maximum).

 

 

Cooling:

 

Forced air included when required.

 

Rated Storage Temperature:

– 25 ° C to +55 ° C

 

Humidity:

 

10 to 85% RH @ 40 ° C Non-Condensing

 

Altitude:

 

Sea level to 3300 Feet (1000 Meters)

 

 

 

Derate 1% per 330 Feet (100 Meters) above 3300

 

 

Feet

 

 

 

Shock:

 

1G

 

 

 

Vibration:

 

0.5G at 10Hz to 60Hz

 

Climatic conditions:

 

Class 3k3, as defined by EN50178 (1998)

 

Safety:

Europe

EN50178 (1998), when installed inside suitable

 

 

enclosure.

 

 

 

North America / Canada

UL508C

 

 

 

Overvoltage Category

Category III (3 phase power), Category II (1 phase

Pollution Degree

Logic power)

 

 

Pollution Degree 2

 

EMC Compliance:

Immunity:

EN50082–1 (1992), EN50082–2 (1992),

 

Radiated Emissions:

EN61800–3

 

 

 

 

EN50081–1(1992) and EN61800–3 when mounted

 

 

inside the specified enclosure. Control and motor

 

 

cables must be screened and correctly installed

 

 

with shielded couplings where they exit the

 

 

enclosure. Control 0V must be connected to

 

 

protective earth/ground.

 

Conducted Emissions:

 

EN50081–1(1992), EN61800–3 unrestricted

 

 

distribution, maximum motor cable length is 25m.

MN735

Specifications & Product Data 6–1

Image 46
Contents Series 35D Inverter Control MN735Table of Contents Appendix a Appendix BPower and Motor Connections Section Quick StartRemote Mode Size 1 and 3 Terminal StripsPower Connection Descriptions Thermistor Connection to motor thermistorAnalog/Digital Signal Descriptions Terminal Signal Name Description RangeLimited Warranty Section General InformationCould result in damage to property Product Notice Intended useOn next Precautions To prevent equipment damage, be certain that the input power Receiving & Inspection Section Receiving & InstallationLocation and Mounting Watts Loss Ratings Catalog No Output Current Inverter SizesInput Power Conditioning Power ConditioningUngrounded Distribution System Impedance + Unshielded and Shielded Couplings Clamp TerminalWire Size AWG MM2Power Connection Descriptions Power and Ground Connections Size 2 Shown Resistance thresholds are Rising temperature trip resistance One control to PE Receiving & Installation MN735 External Brake Resistor Keypad Mode Keypad Connection DiagramStandard Run 3 Wire Mode Standard Run Connection DiagramSpeed 2 Wire Mode Related Parameters10 Epot Connection Diagram 11 Epot Connection Diagram PID 2 Wire Mode 12 PID Connection DiagramReceiving & Installation MN735 Section Start-Up and Operation Keypad DescriptionDisplay Diagnostics MenuDrive Status Indications shown on keypad Menu Level Select Local or Remote Reset to Factory Settings 2 button ResetRemote to Local Password Protection Quick Application SelectionDisplay Parameter Description Range Factory Setting Parameter DefinitionsDisplay Parameter Description Range PI P Gain Analog Output Relay Invert =FALSE =TRUE Proportional Gain P501 Method for Setting-up the PI GainsIntegral P502 Power Dependent Parameters Inverter Size Factory Setting CurrentMaterial Recycle Disposal Routine MaintenanceSaving Your Application Data PackagingReset a Trip Section TroubleshootingTrips General Failures DC Link RippleSection Specifications & Product Data General SpecificationsKeypad Display Control SpecificationsAnalog Inputs Relay Output Analog OutputsDigital Inputs Ratings CatalogDimensions 460VAC 3 Phase Controls Size 2 and 3 460VAC Size 1 and 2 230VAC 1 PhaseSize 3 230VAC 3 Phase Appendix a Dynamic BrakeTable A-1 External Brake Resistor Selection CE Declaration of Conformity Wiring of Shielded Screened CablesAppendix B CE Guidelines EMC Conformity and CE MarkingEMC Wiring Technique CabinetEMC Installation Instructions Cable Screens GroundingInput Signal Cable Grounding Standard EMC Directive Date 1/5/02 EC Declarations of ConformityTion CE Guidelines MN735 Box Ft. Smith, AR 479 Fax 479  Baldor Electric Company MN735 02 C&J