Baldor MN735 manual Analog Output

Page 38

 

Table 4-1

Parameter Definitions Continued

 

Display

Parameter

Description

 

 

Range

Factory

 

 

 

 

 

 

 

Setting

 

 

 

SET::IN Menu Continued

 

 

 

DIN 1 VALUE

The input signal after inversion (if any).

0= False

0

 

~

 

 

 

 

1= True

 

 

DIN 2 VALUE

The input signal after inversion (if any).

0= False

0

 

~

 

 

 

 

1= True

 

 

DIN 3 VALUE

The input signal after inversion (if any).

0= False

0

 

~

 

 

 

 

1= True

 

 

DIN 4 VALUE

The input signal after inversion (if any).

0= False

0

 

~

 

 

 

 

1= True

 

 

AIN 1 VALUE

The analog input signal with scaling and offset.

x.x%

x.x%

 

~

 

 

 

 

 

 

 

AIN 2 VALUE

The analog input signal with scaling and offset.

x.x%

x.x%

 

~

 

 

 

 

 

 

 

 

 

SET::OUT Menu

 

 

 

 

AOUT 1

ANALOG OUTPUT

 

0= NONE

1

 

SOURCE

 

1= DEMAND

 

 

 

0 NONE

Scale

 

2= CURRENT

 

 

 

1 DEMAND %

 

3= PI ERROR

 

 

 

Offset

 

 

 

 

2 CURRENT %

0–10V

 

 

 

3 PI ERROR %

Absolute

 

4= RAISE/LOWER

 

 

 

4 RAISE/LOWER

 

OUTPUT

 

 

 

 

 

 

 

 

OUTPUT%

 

 

 

 

 

AOUT 1 SCALE

 

SCALE

OFFSET

ABS

-300.0 to 300.0

100.0%

 

 

 

 

 

 

 

Value

X

+

X Output

 

 

 

AOUT 1

 

 

 

 

-300.0 to 300.0%

0.00%

 

OFFSET

 

 

 

 

 

 

 

AOUT 1

 

 

 

 

0= False

0

 

ABSOLUTE

 

 

 

 

1= True

 

 

AOUT 1 VALUE

 

 

 

 

-300.0 to 300.0%

0.0%

 

~

 

 

 

 

 

 

 

DOUT 2

DIN4 / DOUT2

 

 

0= NONE (DIN4)

0

 

SOURCE

0 NONE

 

 

1= HEALTH

 

 

 

1 HEALTH

 

 

2= TRIPPED

 

 

 

2 TRIPPED

Invert

 

3= RUNNING

 

 

 

3 RUNNING

 

 

 

 

Output

 

4= AT ZERO

 

 

 

4 AT ZERO

 

 

 

 

 

 

5= AT SPEED

 

 

 

5 AT SPEED

 

 

 

 

 

6 AT LOAD

 

 

6= AT LOAD

 

 

DOUT 2

(OUTPUT) As SIP01. Set to 0 for applications

As SIP01

0

 

INVERT

1 & 5.

 

 

 

 

 

 

DOUT 2

The output signal that represents the OP21

0= False

0

 

VALUE ~

choice.

 

 

 

1= True

 

RELAY

RELAY

SOURCE

0 NONE

 

1

HEALTH

 

2

TRIPPED

 

3

RUNNING

 

4

AT ZERO

 

5

AT SPEED

 

6

AT LOAD

Invert Output

0= NONE

2

1= HEALTH 2= TRIPPED 3= RUNNING 4= AT ZERO 5= AT SPEED 6= AT LOAD

MN735

Start–Up and Operation 4–9

Image 38
Contents Series 35D Inverter Control MN735Table of Contents Appendix a Appendix BPower and Motor Connections Section Quick StartRemote Mode Size 1 and 3 Terminal StripsPower Connection Descriptions Thermistor Connection to motor thermistorAnalog/Digital Signal Descriptions Terminal Signal Name Description RangeLimited Warranty Section General InformationOn next Product Notice Intended useCould result in damage to property Precautions To prevent equipment damage, be certain that the input power Location and Mounting Section Receiving & InstallationReceiving & Inspection Watts Loss Ratings Catalog No Output Current Inverter SizesUngrounded Distribution System Power ConditioningInput Power Conditioning Impedance + Unshielded and Shielded Couplings Clamp TerminalWire Size AWG MM2Power Connection Descriptions Power and Ground Connections Size 2 Shown Resistance thresholds are Rising temperature trip resistance One control to PE Receiving & Installation MN735 External Brake Resistor Keypad Mode Keypad Connection DiagramStandard Run 3 Wire Mode Standard Run Connection DiagramSpeed 2 Wire Mode Related Parameters10 Epot Connection Diagram 11 Epot Connection Diagram PID 2 Wire Mode 12 PID Connection DiagramReceiving & Installation MN735 Section Start-Up and Operation Keypad DescriptionDrive Status Indications shown on keypad Diagnostics MenuDisplay Menu Level Remote to Local Reset to Factory Settings 2 button ResetSelect Local or Remote Password Protection Quick Application Selection Display Parameter Description Range Factory Setting Parameter DefinitionsDisplay Parameter Description Range PI P Gain Analog Output Relay Invert =FALSE =TRUE Integral P502 Method for Setting-up the PI GainsProportional Gain P501 Power Dependent Parameters Inverter Size Factory Setting CurrentMaterial Recycle Disposal Routine MaintenanceSaving Your Application Data PackagingTrips Section TroubleshootingReset a Trip General Failures DC Link RippleSection Specifications & Product Data General SpecificationsAnalog Inputs Control SpecificationsKeypad Display Relay Output Analog OutputsDigital Inputs Ratings CatalogDimensions 460VAC 3 Phase Controls Size 2 and 3 460VAC Size 1 and 2 230VAC 1 PhaseSize 3 230VAC 3 Phase Appendix a Dynamic BrakeTable A-1 External Brake Resistor Selection CE Declaration of Conformity Wiring of Shielded Screened CablesAppendix B CE Guidelines EMC Conformity and CE MarkingEMC Wiring Technique CabinetEMC Installation Instructions Cable Screens GroundingInput Signal Cable Grounding Tion Date 1/5/02 EC Declarations of ConformityStandard EMC Directive CE Guidelines MN735 Box Ft. Smith, AR 479 Fax 479  Baldor Electric Company MN735 02 C&J