Chapter 3: Functional Description

This functional description is intended for the operating personnel of the equipment.

General knowledge of operating conveyor units is required.

Ensure in each case that the operating personnel are sufficiently informed.

The XSV-05/R and XSV-05/2R are designed for conveying dust-free plastic granules and regrind material. Only the XSV-05/2R is capable of conveying two materials.

3-1 Method of Functioning

The single conveyor unit works

 

according to the Venturi Principle. An

 

external compressed air supply is

 

needed.

 

A venturi meter (A) is integrated in the

 

venturi assembly.

 

The venturi meter aspirates the material

 

in the lower part of the tube (C) and then

 

conveys the material into the conveyor

 

hopper using compressed air in the

 

upper part (B). In the hopper loader, the

 

material is separated from the air.

 

The filling level of conveyor hopper is

 

monitored and controlled by a level

 

sensor located on the sight glass below

 

the receiver.

 

Note: The venturi assembly is factory

 

pre-set for optimum conveying. DO NOT

Figure 4: Venturi Assembly

ADJUST the venturi assembly.

 

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

16of 36

Image 17 Contents
SSV-05R Page Parts and Service Department Table of Contents Safety Instructions Page Operating Personnel Explanations and InformationHow to Use This Manual For Your SafetyMaintenance Responsibility Unit Safety Installation XSV-05 Parts General Information Installing the Conveyor Hopper Control and Maintenance Unit Installing the Control and Maintenance UnitVenturi Assembly Connecting the Compressed Air SupplyCheck with the local electricity board for regulations Electrical ConnectionMethod of Functioning Functional DescriptionControl and Maintenance Unit Preparations SetupSetting the Mixing Ratio of the Components XSV-05/2R Units Filling Level Too High Basic Setting of the Filling Level in the Conveyor HopperFine Adjustment of the Filling Level in the Conveyor Hopper Maintenance Daily Maintenance IntervalsXSV-05 Cleaning/Replacing the Filter CartridgeDisassembly Adjusting the Level ProbeProblem TroubleshootingPage Technical Data Dimension Sheet XSV-05/R XSV-05/2R Spare Parts Lists XSV-05R XSV-05/2R Position ID Number Designation Quick Start Guide -XSV Venturi Loader Parts Department Technical Assistance