Sterling SSV-05R, SSV-052R operating instructions Maintenance Intervals, Daily

Page 23

Disconnect the equipment from main electrical supply before starting maintenance procedures to ensure that it cannot be switched on unintentionally. Depressurize all compressed air piping of the equipment before starting maintenance work.

Please observe the maintenance intervals.

Before starting maintenance work, clean the equipment of oil, fuel or lubricants.

Ensure that materials and incidentals required for operation as well as spare parts are disposed of properly and in an environmentally sound manner.

Use only original manufacturer spare parts.

Keep record of all maintenance and repair procedures.

5-1 Maintenance Intervals

Daily:

Check the setting of the pressure regulator.

 

 

 

Empty the water separator.

 

 

 

Check danger signs on the unit for legibility and completeness.

 

 

Monthly:

Clean the cartridge filter and screen (depending on accumulation of

 

dust).

 

 

 

Blow out the filter from the inside using compressed air.

 

 

 

Check the electrical connections for proper functioning.

 

 

Every 6

Check all electrical and mechanical connections for proper fit.

months:

 

Replace filter and screen (depending on accumulation of dust).

 

 

 

The maintenance intervals provided are average values.

The maintenance intervals might be shortened due to your individual process conditions.

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

22 of 36

Image 23
Contents SSV-05R Page Parts and Service Department Table of Contents Safety Instructions Page Operating Personnel Explanations and InformationHow to Use This Manual For Your SafetyMaintenance Responsibility Unit Safety Installation XSV-05 Parts General InformationInstalling the Conveyor Hopper Control and Maintenance Unit Installing the Control and Maintenance UnitVenturi Assembly Connecting the Compressed Air SupplyCheck with the local electricity board for regulations Electrical ConnectionMethod of Functioning Functional DescriptionControl and Maintenance Unit Preparations SetupSetting the Mixing Ratio of the Components XSV-05/2R Units Filling Level Too High Basic Setting of the Filling Level in the Conveyor HopperFine Adjustment of the Filling Level in the Conveyor Hopper Maintenance Daily Maintenance IntervalsXSV-05 Cleaning/Replacing the Filter CartridgeDisassembly Adjusting the Level ProbeProblem TroubleshootingPage Technical Data Dimension Sheet XSV-05/R XSV-05/2R Spare Parts Lists XSV-05R XSV-05/2R Position ID Number Designation Quick Start Guide -XSV Venturi Loader Parts Department Technical Assistance