Sterling SSV-052R, SSV-05R Fine Adjustment of the Filling Level in the Conveyor Hopper

Page 21

Fine Adjustment of the Filling Level in the Conveyor Hopper

Before the fine adjustment, carry through a basic adjustment.

During operation, use a screwdriver to carefully turn the adjustment screw (A) of the level sensor until the desired filling level is reached.

Clockwise rotation makes the filling level fall.

Counter-clockwise rotation makes the filling level rise.

If the filling level in the conveyor hopper cannot be lowered far enough using the level sensor, the pressure on the control and maintenance unit can be reduced gradually.

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

20 of 36

Image 21
Contents SSV-05R Page Parts and Service Department Table of Contents Safety Instructions Page Operating Personnel Explanations and InformationHow to Use This Manual For Your SafetyMaintenance Responsibility Unit Safety Installation XSV-05 Parts General InformationInstalling the Conveyor Hopper Control and Maintenance Unit Installing the Control and Maintenance UnitVenturi Assembly Connecting the Compressed Air SupplyCheck with the local electricity board for regulations Electrical ConnectionMethod of Functioning Functional DescriptionControl and Maintenance Unit Setup Setting the Mixing Ratio of the Components XSV-05/2R UnitsPreparations Filling Level Too High Basic Setting of the Filling Level in the Conveyor HopperFine Adjustment of the Filling Level in the Conveyor Hopper Maintenance Daily Maintenance IntervalsXSV-05 Cleaning/Replacing the Filter CartridgeDisassembly Adjusting the Level ProbeProblem TroubleshootingPage Technical Data Dimension Sheet XSV-05/R XSV-05/2R Spare Parts Lists XSV-05R XSV-05/2R Position ID Number Designation Quick Start Guide -XSV Venturi Loader Parts Department Technical Assistance