Sterling SSV-05R, SSV-052R operating instructions Troubleshooting, Problem

Page 26

5-4 Troubleshooting

PROBLEM

REMEDY (See Test Steps Below)

 

 

The unit is not conveying and is not

A, B, G, H

active.

 

 

 

The unit is not conveying; the

C, F

compressed air valve is switched

 

when the device is switched on.

 

 

 

The unit is not conveying; the

C, D, E, F, I, J, K

compressed air is flowing.

 

 

 

The unit is overfilled.

G, L, M

 

 

The unit is not filled properly.

C, D, E, F, I, J, K, L

 

 

Test steps:

Make sure the unit is switched ON.

Make sure the unit is plugged in and the proper voltage is present. Make sure sufficient compressed air is available 70-90 psi (5-6 bar). Make sure the venturi assembly is inserted in the material.

Make sure the compressed air hose is properly connected to the venturi assembly.

Make sure the compressed air hose is properly connected to the maintenance unit.

Make sure the level sensor is properly adjusted.

Make sure the cable of the level sensor is properly connected. Make sure the filter to is not clogged.

Make sure the screen is not clogged.

Make sure the conveyor vinyl flexible hose is properly connected. Make sure the compressed air supply is properly adjusted.

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

25 of 36

Image 26
Contents SSV-05R Page Parts and Service Department Table of Contents Safety Instructions Page Explanations and Information Operating PersonnelFor Your Safety How to Use This ManualMaintenance Responsibility Unit Safety Installation General Information XSV-05 PartsInstalling the Conveyor Hopper Installing the Control and Maintenance Unit Control and Maintenance UnitConnecting the Compressed Air Supply Venturi AssemblyElectrical Connection Check with the local electricity board for regulationsFunctional Description Method of FunctioningControl and Maintenance Unit Preparations SetupSetting the Mixing Ratio of the Components XSV-05/2R Units Basic Setting of the Filling Level in the Conveyor Hopper Filling Level Too HighFine Adjustment of the Filling Level in the Conveyor Hopper Maintenance Maintenance Intervals DailyCleaning/Replacing the Filter Cartridge XSV-05Adjusting the Level Probe DisassemblyTroubleshooting ProblemPage Technical Data Dimension Sheet XSV-05/R XSV-05/2R Spare Parts Lists XSV-05R XSV-05/2R Position ID Number Designation Quick Start Guide -XSV Venturi Loader Technical Assistance Parts Department