2-4 Connecting the Compressed Air Supply

Before connecting the compressed air supply, check the following:

Check compressed air piping for correct installation and assembly.

Check the fittings, length and quality of the hose connections for agreement with requirements.

Check all compressed air lines for leakages.

You need a compressed air supply with 70-90 psi (5-6 bar) system pressure.

The air should be free of oil and water.

1.Find the compressed air hose, which has been supplied.

2.Connect it to the venturi assembly and to the control and maintenance unit.

3.The compressed-air hose is firmly pressed into each connecting socket.

4.Connect the control and maintenance unit to the compressed air supply. Max. input pressure 145 psi (10 bar) system pressure.

5.Set the pressure on the pressure reducer at 70-90 psi (5-6 bar).

Figure 3: Venturi Assembly

Maximum input pressure: 145 psi (10 bar) system overpressure.

Maximum output pressure: 90 psi (6 bar).

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

14 of 36

Image 15
Contents SSV-05R Page Parts and Service Department Table of Contents Safety Instructions Page Operating Personnel Explanations and InformationHow to Use This Manual For Your SafetyMaintenance Responsibility Unit Safety Installation XSV-05 Parts General InformationInstalling the Conveyor Hopper Control and Maintenance Unit Installing the Control and Maintenance UnitVenturi Assembly Connecting the Compressed Air SupplyCheck with the local electricity board for regulations Electrical ConnectionMethod of Functioning Functional DescriptionControl and Maintenance Unit Setup Setting the Mixing Ratio of the Components XSV-05/2R UnitsPreparations Filling Level Too High Basic Setting of the Filling Level in the Conveyor HopperFine Adjustment of the Filling Level in the Conveyor Hopper Maintenance Daily Maintenance IntervalsXSV-05 Cleaning/Replacing the Filter CartridgeDisassembly Adjusting the Level ProbeProblem TroubleshootingPage Technical Data Dimension Sheet XSV-05/R XSV-05/2R Spare Parts Lists XSV-05R XSV-05/2R Position ID Number Designation Quick Start Guide -XSV Venturi Loader Parts Department Technical Assistance