| Position | Freq |
| Welding Current at the dial position (A) |
| |||||
|
|
|
|
|
|
|
|
| ||
| MIN | 1 | 2 | 3 | 4 | 5 |
| MAX | ||
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ECO |
| 30 | 45 | 70 | 95 | 120 | 145 |
| 160 |
1 Person |
|
|
|
|
|
|
|
|
|
|
Single | 50Hz | 70 | 90 | 135 | 175 | 215 | 260 |
| 280 | |
|
|
|
|
|
|
|
|
|
| |
| 60Hz | 85 | 110 | 155 | 200 | 245 | 290 |
| 310 | |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
2 Persons | Dual | 50Hz | 35 | 45 | 70 | 95 | 115 | 140 |
| 150 |
|
|
|
|
|
|
|
|
| ||
60Hz | 45 | 55 | 80 | 105 | 125 | 150 |
| 160 | ||
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
The values are for reference only. The length or the ambient temperature each affects the value. When the remote control box is used, the value may change to some degree.
(2) DGW310MC
The current adjustable range by the dial changes at the output selector switch position.
1 Turn the selector switch properly according to operation. | Current |
| |
2 Adjust the voltage by the current adjustable dial. Refer to | Dial |
the following chart next. |
|
Selector |
|
Switch |
|
Output
Terminal
Position | Freq | Welding Current at the dial position (A) | |||||||
|
|
|
|
|
|
| |||
MIN | 1 | 2 | 3 | 4 | 5 | MAX | |||
|
| ||||||||
|
|
|
|
|
|
|
|
| |
ECO |
| 30 | 45 | 70 | 95 | 120 | 145 | 160 | |
|
|
|
|
|
|
|
|
| |
Regular | 50Hz | 35 | 60 | 110 | 160 | 205 | 255 | 280 | |
|
|
|
|
|
|
|
| ||
60Hz | 45 | 70 | 125 | 180 | 230 | 285 | 310 | ||
| |||||||||
|
|
|
|
|
|
|
|
|
The values are for reference only. The length or the ambient temperature each affects the value. When the remote control box is used, the value may change to some degree.