10. Simultaneous use of Generating and Welding
The circuit breakers react on the AC power supply circuit only. In the simultaneous use of welding and generating, there may be happen overload to the engine. Refer to the following table and limit AC power use.
Limitation of AC Power Supply in the simultaneous use of welding and generating (60Hz)
DGW310DMC
Welding Output
Rod/Current Select
2.0mm/60A Dual
2.6mm/120A Dual
3.2mm/140A Dual
4.0mm/170A Dual
5.0mm/240A Single
6.0mm/300A Single
AC Power Output
9.3kVA | 7.4kVA |
7.2kVA | 5.7kVA |
6.4kVA | 5.1kVA |
|
|
5.2kVA | 4.1kVA |
2.0kVA | 1.6kVA |
0kVA | 0kVA |
|
|
The
DGW310MC
Welding Output
Rod/Current Select
2.0mm/60A Regular
2.6mm/120A Regular
3.2mm/140A Regular
4.0mm/170A Regular
5.0mm/240A Regular
6.0mm/300A Regular
AC Power Output
| ||||
|
|
|
|
|
| 9.3kVA | 7.4kVA | ||
| 7.2kVA | 5.7kVA | ||
| 6.4kVA | 5.1kVA | ||
| 5.2kVA | 4.1kVA | ||
| 2.0kVA | 1.6kVA | ||
| 0kVA |
| 0kVA |
|
|
|
| ||
|
|
|
|
|
The
Caution
<Simultaneous> use of Welding and AC Power is NOT available. Avoid simultaneous use in the case high welding quality is required.