40146

Gun 1 Trigger

uint32

NONE

0

= Gun not triggered

 

 

Input Status

 

 

1

= Gun triggered

 

 

 

 

 

 

 

 

 

 

 

 

24

40148

Gun 2 Trigger

uint32

NONE

0

= Gun not triggered

 

 

 

 

 

 

 

 

 

Input Status

 

 

1

= Gun triggered

 

 

 

 

 

25

40150

Gun 3 Trigger

uint32

NONE

0 = Gun not triggered

 

 

Input Status

 

 

1

= Gun triggered

 

 

 

 

 

26

40152

Gun 4 Trigger

uint32

NONE

0

= Gun not triggered

 

 

Input Status

 

 

1

= Gun triggered

 

 

 

 

 

27

40154

Safety Interlock

uint32

NONE

0

= Open

 

 

Input Status

 

 

1

= Closed

 

 

 

 

 

28

40200

Command

uint32

NONE

0

:= NOP

 

 

Acknowledge

 

 

1

= BUSY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= ACK

 

 

 

 

 

3

= NAK

 

 

 

 

 

4

= ERR

29

40202

Command Return

uint32

N/A

N/A

 

 

0

 

 

 

 

30

40204

Command Return

uint32

N/A

N/A

 

 

1

 

 

 

 

31

40206

Command Return

uint32

N/A

N/A

 

 

2

 

 

 

 

32

40208

Command Return

uint32

N/A

N/A

 

 

3

 

 

 

 

33

40210

Command Return

uint32

N/A

N/A

 

 

4

 

 

 

 

34

40212

Command Return

uint32

N/A

N/A

 

 

5

 

 

 

 

35

40214

Command Return

uint32

N/A

N/A

 

 

6

 

 

 

 

36

40216

Command Return

uint32

N/A

N/A

 

 

7

 

 

 

 

37

N/A

Time

uin32

sec

0

– 4,294,967,295

 

 

 

 

 

 

 

38

N/A

Software Version

uint32

NONE

0

– 99

 

 

– Major

 

 

 

 

39

N/A

Software Version

uint32

NONE

0

– 99

 

 

– Minor

 

 

 

 

40

N/A

Software Version

uint32

NONE

0

– 999

 

 

– Build

 

 

 

 

 

These registers are not used.

 

DCS Register

 

 

 

 

 

 

 

 

 

 

 

 

 

332564B

35

Image 35
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsContents Manual No Related ManualsManual No Description 0359 ModelsECB Labels Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Moisture Sensitivity of Isocyanates Important Isocyanate ISO InformationIsocyanate Conditions Keep Components a and B SeparateGeneral Information ADM Display USB Download ProcedureAdvanced Display Module ADM USB Upload Procedure ADM Keys and Indicators Function ADM Keys and IndicatorsKey Function Soft Key IconsSoft Key Functions Key Function Screen Icons Navigating the ScreensPre-Operation Tasks Pre-operation ChecklistPower On Valve Settings Initial System SetupFlush Before Using Equipment With Color Change Without Color ChangePrime and Fill the System Operation Using Automatic Display Module ADMSpraying Flush Mixed Material PurgingColor Change System ShutdownFlush the System Single Color SystemPD2K Discrete I/O Connections Operation Using a Programmable Logic Controller PLCNetwork Communications and Discrete I/O Discrete I/OAnalog Inputs Digital InputsKEY Discrete I/O Connections on EfcmCGM Kits Communication Gateway Module CGM DetailsCGM Overview ProMix PD2K Network Outputs Output Register 00 Current System ModeNumber Operation Mode Description Network Communication I/O Data MapOutput Register 06 Actual Mix Ratio Output Registers 01, 02, 03, and 04 Pump StatusPump States for Output Registers Description Ber Output Register 05 Actual Mix FlowOutput Register 12 Active Recipe Material B Flush Sequence Output Register 14 Active Recipe Potlife Timeout Set PointOutput Register 27 Safety Interlock Input Status Output Registers 28 36 DCS Command StructureOutput Register 38 40 Software Version Output Register 37 TimeOperation Using a Programmable Logic Controller PLC None Network Output Data Map Read OnlyPSI = ERR = Busy= ACK = NAKProMix PD2K Network Inputs Input Register 00 System Mode CommandInput Register 07 Go to Recipe Number Input Register 02 Flush/Prime Pump CommandInput Register 03 Mix Pump 1 Control Set Point Input Register 10 Gun 1 Trigger Input Register 08 Clear Active AlarmInput Registers 14 21 DCS Command Structure Input Register 09 Job CompleteOperation Using a Programmable Logic Controller PLC Network Input Data Map Write/Read 40180 Gun 3 Trigger Uint32 Purge Mode Sequence Operation Flow ChartsInactive Pump Flush and Prime Sequences Flush Pump CommandChange Color Change SequenceStandby Mix Ready? no Mixing SequenceClear Active Alarm Alarm Clearing SequenceDynamic Command Description Network Communication Dynamic Command Structure DCSDCS List of DCS CommandsDynamic Commands with Command ID Write User IDWrite Recipe Write Flush Sequence Read User ID Write Fluid Control ModeRead Flush Sequence Read RecipeRead Fluid Control Mode Yymmdd Read Job InfoExample Ascii Character String Decode Algorithm Read Alarm InfoYymmdddw Read Event Info Flow Control System Home Screen Run Mode ScreensOpening Screen See Advanced Screen 1, page 82, to set Home Screen Key Description DetailsKey Description Key Description Spray Screen Spray Screen, in Standby ModeFill Screen, Color a Selected Fill ScreenUsage Screen Usage ScreenEvents Screen Errors ScreenJobs Screen Password Screen Setup Mode ScreensSystem Screen Mix Pressure Tolerance Mix Idle TimeoutMix No Flow Timeout Low Flow TimeoutHose Length and Diameter Gun Hose LengthGun Hose Diameter Mix At WallGateway ID EnableManual Override Gun Trigger SignalFlow Control Setpoint Signal Fluid ControlRecipe Screen Flush Screen Pump Screen Default Settings Not Selected Default Settings SelectedPump Screen 3, Pressure Monitoring Disabled Pressure Alarm and Deviation LimitsCalibrate Screen Calibration ScreensVolume Check Screen Enter Measured Volume of Solvent Maintenance Screen Maintenance ScreensMaintenance Screen 4, Color Valve Resets Advanced Screen Download Depth Enable USB Downloads/UploadsLog 90% Full Advisory Enabled Display UnitsPerform the pressure check Calibration ChecksPump Pressure Check Pump Volume Check Scroll to Calibrate Screen 3, Solvent Meter CalibrationMultiple Color Systems Color ChangeSingle Color Systems Gun Trigger Input Function System ErrorsTo Clear Error and Restart Mix Errors Code Type Description Problem Cause Solution Error CodesPurge Errors Code Type Description Problem Cause Solution Pumping Errors Code Type Description Problem Cause Solution EBH# Code Type Description Problem Cause SolutionSAD1 Pressure Errors Code Type Description Problem Cause Solution Qbdx QadxCAC# System Errors Code Type Description Problem Cause SolutionEmix CA0XCddx CagxCDC# USB Errors Code Type Description Problem Cause Solution Wxuu WxudUSB B9SX B9AXB9BX ENT# Calibration Errors Code Type Name DescriptionEND# ENS0Code Type Name Description Maintenance ErrorsFlushing MaintenancePreventive Maintenance Schedule Cleaning the ADMPositive Displacement Metric Proportioner Technical DataFor Graco Canada Customers Graco Standard WarrantyGraco Information