Setup Mode Screens

System Screen 4

System screen 4 sets the following system operating parameters.

Figure 31 System Screen 4

Gateway ID

Select the desired Gateway ID from the dropdown menu.

Enable

Uncheck Enable while setting the IP Address, Subnet mask, Gateway, DNS1 or DNS2. When the settings are loaded, check the Enable box to write the new settings to the selected Gateway.

Check this box to enable the selected Gateway so that the PLC can communicate with it.

DHCP

Select this box if your system has a Dynamic Host Configuration Protocol (DHCP). This protocol assigns unique IP addresses to devices, then releases and renews these addresses as devices leave and rejoin the network. If selected, the IP Address, Subnet, and Gateway fields will not be editable and will display the addresses supplied by the DHCP.

TCP/IP

Use the remaining fields to set the IP address, subnet mask, Gateway, DNS1, and DNS2.

70

332564B

Image 70
Contents Important Safety Instructions ProMix PD2K Proportioner for Automatic Spray ApplicationsContents Manual No Description Related ManualsManual No ECB Labels Models0359 Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Keep Components a and B Separate Important Isocyanate ISO InformationIsocyanate Conditions Moisture Sensitivity of IsocyanatesGeneral Information Advanced Display Module ADM USB Download ProcedureADM Display USB Upload Procedure ADM Keys and Indicators ADM Keys and Indicators FunctionSoft Key Functions Soft Key IconsKey Function Key Function Navigating the Screens Screen IconsPower On Pre-operation ChecklistPre-Operation Tasks Flush Before Using Equipment Initial System SetupValve Settings Without Color Change With Color ChangeOperation Using Automatic Display Module ADM Prime and Fill the SystemSpraying Purging Flush Mixed MaterialSingle Color System ShutdownFlush the System Color Change SystemDiscrete I/O Operation Using a Programmable Logic Controller PLCNetwork Communications and Discrete I/O PD2K Discrete I/O ConnectionsDigital Inputs Analog InputsDiscrete I/O Connections on Efcm KEYCGM Overview Communication Gateway Module CGM DetailsCGM Kits Network Communication I/O Data Map Output Register 00 Current System ModeNumber Operation Mode Description ProMix PD2K Network OutputsOutput Register 05 Actual Mix Flow Output Registers 01, 02, 03, and 04 Pump StatusPump States for Output Registers Description Ber Output Register 06 Actual Mix RatioOutput Registers 28 36 DCS Command Structure Output Register 14 Active Recipe Potlife Timeout Set PointOutput Register 27 Safety Interlock Input Status Output Register 12 Active Recipe Material B Flush SequenceOutput Register 37 Time Output Register 38 40 Software VersionOperation Using a Programmable Logic Controller PLC Network Output Data Map Read Only NonePSI = NAK = Busy= ACK = ERRInput Register 00 System Mode Command ProMix PD2K Network InputsInput Register 03 Mix Pump 1 Control Set Point Input Register 02 Flush/Prime Pump CommandInput Register 07 Go to Recipe Number Input Register 09 Job Complete Input Register 08 Clear Active AlarmInput Registers 14 21 DCS Command Structure Input Register 10 Gun 1 TriggerOperation Using a Programmable Logic Controller PLC Network Input Data Map Write/Read 40180 Gun 3 Trigger Uint32 Operation Flow Charts Purge Mode SequenceFlush Pump Command Inactive Pump Flush and Prime SequencesColor Change Sequence ChangeMixing Sequence Standby Mix Ready? noAlarm Clearing Sequence Clear Active AlarmNetwork Communication Dynamic Command Structure DCS Dynamic Command DescriptionWrite User ID List of DCS CommandsDynamic Commands with Command ID DCSWrite Recipe Write Flush Sequence Write Fluid Control Mode Read User IDRead Recipe Read Flush SequenceRead Fluid Control Mode Read Job Info YymmddYymmdddw Read Alarm InfoExample Ascii Character String Decode Algorithm Read Event Info Flow Control System Opening Screen Run Mode ScreensHome Screen Home Screen Key Description Details See Advanced Screen 1, page 82, to setKey Description Key Description Spray Screen, in Standby Mode Spray ScreenFill Screen Fill Screen, Color a SelectedUsage Screen Usage ScreenJobs Screen Errors ScreenEvents Screen Setup Mode Screens Password ScreenSystem Screen Low Flow Timeout Mix Idle TimeoutMix No Flow Timeout Mix Pressure ToleranceMix At Wall Gun Hose LengthGun Hose Diameter Hose Length and DiameterEnable Gateway IDFluid Control Gun Trigger SignalFlow Control Setpoint Signal Manual OverrideRecipe Screen Flush Screen Pump Screen Default Settings Selected Default Settings Not SelectedPressure Alarm and Deviation Limits Pump Screen 3, Pressure Monitoring DisabledCalibration Screens Calibrate ScreenVolume Check Screen Enter Measured Volume of Solvent Maintenance Screens Maintenance ScreenMaintenance Screen 4, Color Valve Resets Advanced Screen Display Units Enable USB Downloads/UploadsLog 90% Full Advisory Enabled Download DepthPump Pressure Check Calibration ChecksPerform the pressure check Pump Volume Check Solvent Meter Calibration Scroll to Calibrate Screen 3,Single Color Systems Color ChangeMultiple Color Systems To Clear Error and Restart System ErrorsGun Trigger Input Function Purge Errors Code Type Description Problem Cause Solution Error CodesMix Errors Code Type Description Problem Cause Solution Pumping Errors Code Type Description Problem Cause Solution Code Type Description Problem Cause Solution EBH#SAD1 Pressure Errors Code Type Description Problem Cause Solution Qadx QbdxCA0X System Errors Code Type Description Problem Cause SolutionEmix CAC#CDC# CagxCddx USB Errors Code Type Description Problem Cause Solution USB WxudWxuu B9BX B9AXB9SX ENS0 Calibration Errors Code Type Name DescriptionEND# ENT#Maintenance Errors Code Type Name DescriptionCleaning the ADM MaintenancePreventive Maintenance Schedule FlushingTechnical Data Positive Displacement Metric ProportionerGraco Information Graco Standard WarrantyFor Graco Canada Customers