Graco 332564B important safety instructions Flush Screen

Page 73

Flush Screen

Figure 35 Flush Screen

Flush Number

Enter the desired flush sequence (1-5). For hard to flush colors, select a longer sequence. 1 is the default, and should be designated for the longest, most thorough flush duration.

Gun Purge Time

Enter the spray device purge time (0 to 999 seconds).

Setup Mode Screens

Initial Flush

Enter the initial flush volume (0 to 9999 cc).

Final Flush

Enter the final flush volume (0 to 9999 cc).

Wash Cycles

A Wash Cycle activates the pump with the valves closed, to use pumping motion to thoroughly clean the pump. Enter the desired number of wash cycles (0 to 99). Entering a number will make the Strokes per Cycle field active.

Strokes per Wash Cycle

Enter the desired pump strokes per wash cycle (0 to 99). Default is 1.

332564B

73

Image 73
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsContents Manual No Description Related ManualsManual No ECB Labels Models0359 Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Isocyanate Conditions Important Isocyanate ISO InformationKeep Components a and B Separate Moisture Sensitivity of IsocyanatesGeneral Information Advanced Display Module ADM USB Download ProcedureADM Display USB Upload Procedure ADM Keys and Indicators Function ADM Keys and IndicatorsSoft Key Functions Soft Key IconsKey Function Key Function Screen Icons Navigating the ScreensPower On Pre-operation ChecklistPre-Operation Tasks Flush Before Using Equipment Initial System SetupValve Settings With Color Change Without Color ChangePrime and Fill the System Operation Using Automatic Display Module ADMSpraying Flush Mixed Material PurgingFlush the System ShutdownSingle Color System Color Change SystemNetwork Communications and Discrete I/O Operation Using a Programmable Logic Controller PLCDiscrete I/O PD2K Discrete I/O ConnectionsAnalog Inputs Digital InputsKEY Discrete I/O Connections on EfcmCGM Overview Communication Gateway Module CGM DetailsCGM Kits Number Operation Mode Description Output Register 00 Current System ModeNetwork Communication I/O Data Map ProMix PD2K Network OutputsPump States for Output Registers Description Ber Output Registers 01, 02, 03, and 04 Pump StatusOutput Register 05 Actual Mix Flow Output Register 06 Actual Mix RatioOutput Register 27 Safety Interlock Input Status Output Register 14 Active Recipe Potlife Timeout Set PointOutput Registers 28 36 DCS Command Structure Output Register 12 Active Recipe Material B Flush SequenceOutput Register 38 40 Software Version Output Register 37 TimeOperation Using a Programmable Logic Controller PLC None Network Output Data Map Read OnlyPSI = ACK = Busy= NAK = ERRProMix PD2K Network Inputs Input Register 00 System Mode CommandInput Register 03 Mix Pump 1 Control Set Point Input Register 02 Flush/Prime Pump CommandInput Register 07 Go to Recipe Number Input Registers 14 21 DCS Command Structure Input Register 08 Clear Active AlarmInput Register 09 Job Complete Input Register 10 Gun 1 TriggerOperation Using a Programmable Logic Controller PLC Network Input Data Map Write/Read 40180 Gun 3 Trigger Uint32 Purge Mode Sequence Operation Flow ChartsInactive Pump Flush and Prime Sequences Flush Pump CommandChange Color Change SequenceStandby Mix Ready? no Mixing SequenceClear Active Alarm Alarm Clearing SequenceDynamic Command Description Network Communication Dynamic Command Structure DCSDynamic Commands with Command ID List of DCS CommandsWrite User ID DCSWrite Recipe Write Flush Sequence Read User ID Write Fluid Control ModeRead Flush Sequence Read RecipeRead Fluid Control Mode Yymmdd Read Job InfoYymmdddw Read Alarm InfoExample Ascii Character String Decode Algorithm Read Event Info Flow Control System Opening Screen Run Mode ScreensHome Screen See Advanced Screen 1, page 82, to set Home Screen Key Description DetailsKey Description Key Description Spray Screen Spray Screen, in Standby ModeFill Screen, Color a Selected Fill ScreenUsage Screen Usage ScreenJobs Screen Errors ScreenEvents Screen Password Screen Setup Mode ScreensSystem Screen Mix No Flow Timeout Mix Idle TimeoutLow Flow Timeout Mix Pressure ToleranceGun Hose Diameter Gun Hose LengthMix At Wall Hose Length and DiameterGateway ID EnableFlow Control Setpoint Signal Gun Trigger SignalFluid Control Manual OverrideRecipe Screen Flush Screen Pump Screen Default Settings Not Selected Default Settings SelectedPump Screen 3, Pressure Monitoring Disabled Pressure Alarm and Deviation LimitsCalibrate Screen Calibration ScreensVolume Check Screen Enter Measured Volume of Solvent Maintenance Screen Maintenance ScreensMaintenance Screen 4, Color Valve Resets Advanced Screen Log 90% Full Advisory Enabled Enable USB Downloads/UploadsDisplay Units Download DepthPump Pressure Check Calibration ChecksPerform the pressure check Pump Volume Check Scroll to Calibrate Screen 3, Solvent Meter CalibrationSingle Color Systems Color ChangeMultiple Color Systems To Clear Error and Restart System ErrorsGun Trigger Input Function Purge Errors Code Type Description Problem Cause Solution Error CodesMix Errors Code Type Description Problem Cause Solution Pumping Errors Code Type Description Problem Cause Solution EBH# Code Type Description Problem Cause SolutionSAD1 Pressure Errors Code Type Description Problem Cause Solution Qbdx QadxEmix System Errors Code Type Description Problem Cause SolutionCA0X CAC#CDC# CagxCddx USB Errors Code Type Description Problem Cause Solution USB WxudWxuu B9BX B9AXB9SX END# Calibration Errors Code Type Name DescriptionENS0 ENT#Code Type Name Description Maintenance ErrorsPreventive Maintenance Schedule MaintenanceCleaning the ADM FlushingPositive Displacement Metric Proportioner Technical DataGraco Information Graco Standard WarrantyFor Graco Canada Customers