Graco 332564B Pressure Errors Code Type Description Problem Cause Solution

Page 93

System Errors

Pressure Errors

NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the applicable component number, which can vary. The unit’s display will show the applicable number as the last digit in the code. For example, the P6F# code listed in this table will be displayed as P6F1 if the affected component is pump 1, P6F2 for pump 2, and so on.

Code

Type

Description

Problem

Cause

Solution

 

 

 

 

 

 

F6F#

Alarm

Press.

No inlet pressure

Disconnected

Verify transducer is

 

 

Sens.

transducer is detected

transducer.

connected properly.

 

 

Removed

when the system is

 

Replace if reconnecting

 

 

Inlet #

expecting one.

 

does not eliminate the

 

 

 

 

 

alarm.

P1F#

Alarm

Pressure

The inlet pressure on

 

Increase inlet pressure.

 

 

Low Inlet

pump # is less than

 

 

 

 

Pump #

the user-entered alarm

 

 

 

 

 

limit.

 

 

P2F#

Devi-

Pressure

The inlet pressure on

 

Increase inlet pressure.

 

ation

Low Inlet

pump # is less than the

 

 

 

 

Pump #

user-entered deviation

 

 

 

 

 

limit.

 

 

P3D#

Devi-

Pressure

The outlet pressure

 

Relieve system

 

ation

High Outlet

on pump # is greater

 

pressure.

 

 

Pump #

than the user entered

 

 

 

 

 

deviation limit.

 

 

P3F#

Devi-

Pressure

The inlet pressure

 

Decrease inlet

 

ation

High Inlet

on pump # is greater

 

pressure.

 

 

Pump #

than the user-entered

 

 

 

 

 

deviation limit.

 

 

P4D#

Alarm

Pressure

The outlet pressure on

 

Relieve system

 

 

High Outlet

pump # is greater than

 

pressure.

 

 

Pump #

the user entered alarm

 

 

 

 

 

limit.

 

 

P4F#

Alarm

Pressure

The inlet pressure on

 

Decrease inlet

 

 

High Inlet

pump # is greater than

 

pressure.

 

 

Pump #

the user-entered alarm

 

 

 

 

 

limit.

 

 

P6D#

Alarm

Press.

No outlet pressure

Disconnected

Verify transducer is

 

 

Sens.

transducer is detected

transducer.

connected properly.

 

 

Removed

when the system is

 

Replace if reconnecting

 

 

Outlet #

expecting one.

 

does not eliminate the

 

 

 

 

 

alarm.

P9D#

Alarm

Press.

Outlet pressure

Outlet pressure

Relieve system

 

 

Sens.

transducer has failed.

transducer has failed or

pressure. Verify

 

 

Failed

 

the pressure is above

connections, or replace

 

 

Outlet #

 

the readable range.

if reconnecting does

 

 

 

 

 

not eliminate the alarm.

332564B

93

Image 93
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsContents Related Manuals Manual No DescriptionManual No Models ECB Labels0359 Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Isocyanate Conditions Important Isocyanate ISO InformationKeep Components a and B Separate Moisture Sensitivity of IsocyanatesGeneral Information USB Download Procedure Advanced Display Module ADMADM Display USB Upload Procedure ADM Keys and Indicators Function ADM Keys and IndicatorsSoft Key Icons Soft Key FunctionsKey Function Key Function Screen Icons Navigating the ScreensPre-operation Checklist Power OnPre-Operation Tasks Initial System Setup Flush Before Using EquipmentValve Settings With Color Change Without Color ChangePrime and Fill the System Operation Using Automatic Display Module ADMSpraying Flush Mixed Material PurgingFlush the System ShutdownSingle Color System Color Change SystemNetwork Communications and Discrete I/O Operation Using a Programmable Logic Controller PLCDiscrete I/O PD2K Discrete I/O ConnectionsAnalog Inputs Digital InputsKEY Discrete I/O Connections on EfcmCommunication Gateway Module CGM Details CGM OverviewCGM Kits Number Operation Mode Description Output Register 00 Current System ModeNetwork Communication I/O Data Map ProMix PD2K Network OutputsPump States for Output Registers Description Ber Output Registers 01, 02, 03, and 04 Pump StatusOutput Register 05 Actual Mix Flow Output Register 06 Actual Mix RatioOutput Register 27 Safety Interlock Input Status Output Register 14 Active Recipe Potlife Timeout Set PointOutput Registers 28 36 DCS Command Structure Output Register 12 Active Recipe Material B Flush SequenceOutput Register 38 40 Software Version Output Register 37 TimeOperation Using a Programmable Logic Controller PLC None Network Output Data Map Read OnlyPSI = ACK = Busy= NAK = ERRProMix PD2K Network Inputs Input Register 00 System Mode CommandInput Register 02 Flush/Prime Pump Command Input Register 03 Mix Pump 1 Control Set PointInput Register 07 Go to Recipe Number Input Registers 14 21 DCS Command Structure Input Register 08 Clear Active AlarmInput Register 09 Job Complete Input Register 10 Gun 1 TriggerOperation Using a Programmable Logic Controller PLC Network Input Data Map Write/Read 40180 Gun 3 Trigger Uint32 Purge Mode Sequence Operation Flow ChartsInactive Pump Flush and Prime Sequences Flush Pump CommandChange Color Change SequenceStandby Mix Ready? no Mixing SequenceClear Active Alarm Alarm Clearing SequenceDynamic Command Description Network Communication Dynamic Command Structure DCSDynamic Commands with Command ID List of DCS CommandsWrite User ID DCSWrite Recipe Write Flush Sequence Read User ID Write Fluid Control ModeRead Flush Sequence Read RecipeRead Fluid Control Mode Yymmdd Read Job InfoRead Alarm Info YymmdddwExample Ascii Character String Decode Algorithm Read Event Info Flow Control System Run Mode Screens Opening ScreenHome Screen See Advanced Screen 1, page 82, to set Home Screen Key Description DetailsKey Description Key Description Spray Screen Spray Screen, in Standby ModeFill Screen, Color a Selected Fill ScreenUsage Screen Usage ScreenErrors Screen Jobs ScreenEvents Screen Password Screen Setup Mode ScreensSystem Screen Mix No Flow Timeout Mix Idle TimeoutLow Flow Timeout Mix Pressure ToleranceGun Hose Diameter Gun Hose LengthMix At Wall Hose Length and DiameterGateway ID EnableFlow Control Setpoint Signal Gun Trigger SignalFluid Control Manual OverrideRecipe Screen Flush Screen Pump Screen Default Settings Not Selected Default Settings SelectedPump Screen 3, Pressure Monitoring Disabled Pressure Alarm and Deviation LimitsCalibrate Screen Calibration ScreensVolume Check Screen Enter Measured Volume of Solvent Maintenance Screen Maintenance ScreensMaintenance Screen 4, Color Valve Resets Advanced Screen Log 90% Full Advisory Enabled Enable USB Downloads/UploadsDisplay Units Download DepthCalibration Checks Pump Pressure CheckPerform the pressure check Pump Volume Check Scroll to Calibrate Screen 3, Solvent Meter CalibrationColor Change Single Color SystemsMultiple Color Systems System Errors To Clear Error and RestartGun Trigger Input Function Error Codes Purge Errors Code Type Description Problem Cause SolutionMix Errors Code Type Description Problem Cause Solution Pumping Errors Code Type Description Problem Cause Solution EBH# Code Type Description Problem Cause SolutionSAD1 Pressure Errors Code Type Description Problem Cause Solution Qbdx QadxEmix System Errors Code Type Description Problem Cause SolutionCA0X CAC#Cagx CDC#Cddx USB Errors Code Type Description Problem Cause Solution Wxud USBWxuu B9AX B9BXB9SX END# Calibration Errors Code Type Name DescriptionENS0 ENT#Code Type Name Description Maintenance ErrorsPreventive Maintenance Schedule MaintenanceCleaning the ADM FlushingPositive Displacement Metric Proportioner Technical DataGraco Standard Warranty Graco InformationFor Graco Canada Customers