Run Mode Screens

Home Screen Key

 

 

 

 

 

 

 

 

 

Key

Description

Details

 

 

A

Date and Time

See Advanced Screen 1, page 82, to set.

B

Menu Bar

Run Screens. Use left and right arrow keys to scroll through the

 

 

different Run screens:

 

 

 

 

Home (shown in Diagnostic Mode)

 

 

Spray (see Spray Screen, page 62)

 

 

Fill (see Fill Screen, page 63), available only if manual override

 

 

 

is enabled on System Screen 5, page 71.

 

 

Usage (see Usage Screen, page 64)

 

 

Jobs (see Jobs Screen, page 65)

 

 

 

Errors (see Errors Screen, page 65)

 

 

Events (see Events Screen, page 65)

 

 

 

 

C

Status Bar

System Status: Displays the current mode of operation:

 

 

 

 

 

 

 

 

Pump Off

Change Recipe

 

 

Standby

Idle

 

 

Startup

Prime Pump

 

 

Mix

Calibrate

 

 

Fill

Stall Test

 

 

Purge

Maintenance Test

 

 

Shutdown

 

 

 

 

 

 

 

D

Error Status

Displays any active error code.

 

 

 

 

 

 

 

 

332564B

59

Image 59 Contents
ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsContents Manual No Related ManualsManual No Description 0359 ModelsECB Labels Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Moisture Sensitivity of Isocyanates Important Isocyanate ISO InformationIsocyanate Conditions Keep Components a and B SeparateGeneral Information ADM Display USB Download ProcedureAdvanced Display Module ADM USB Upload Procedure ADM Keys and Indicators Function ADM Keys and IndicatorsKey Function Soft Key IconsSoft Key Functions Key Function Screen Icons Navigating the ScreensPre-Operation Tasks Pre-operation ChecklistPower On Valve Settings Initial System SetupFlush Before Using Equipment With Color Change Without Color ChangePrime and Fill the System Operation Using Automatic Display Module ADMSpraying Flush Mixed Material PurgingColor Change System ShutdownFlush the System Single Color SystemPD2K Discrete I/O Connections Operation Using a Programmable Logic Controller PLCNetwork Communications and Discrete I/O Discrete I/OAnalog Inputs Digital InputsKEY Discrete I/O Connections on EfcmCGM Kits Communication Gateway Module CGM DetailsCGM Overview ProMix PD2K Network Outputs Output Register 00 Current System ModeNumber Operation Mode Description Network Communication I/O Data MapOutput Register 06 Actual Mix Ratio Output Registers 01, 02, 03, and 04 Pump StatusPump States for Output Registers Description Ber Output Register 05 Actual Mix FlowOutput Register 12 Active Recipe Material B Flush Sequence Output Register 14 Active Recipe Potlife Timeout Set PointOutput Register 27 Safety Interlock Input Status Output Registers 28 36 DCS Command StructureOutput Register 38 40 Software Version Output Register 37 TimeOperation Using a Programmable Logic Controller PLC None Network Output Data Map Read OnlyPSI = ERR = Busy= ACK = NAKProMix PD2K Network Inputs Input Register 00 System Mode CommandInput Register 07 Go to Recipe Number Input Register 02 Flush/Prime Pump CommandInput Register 03 Mix Pump 1 Control Set Point Input Register 10 Gun 1 Trigger Input Register 08 Clear Active AlarmInput Registers 14 21 DCS Command Structure Input Register 09 Job CompleteOperation Using a Programmable Logic Controller PLC Network Input Data Map Write/Read 40180 Gun 3 Trigger Uint32 Purge Mode Sequence Operation Flow ChartsInactive Pump Flush and Prime Sequences Flush Pump CommandChange Color Change SequenceStandby Mix Ready? no Mixing SequenceClear Active Alarm Alarm Clearing SequenceDynamic Command Description Network Communication Dynamic Command Structure DCSDCS List of DCS CommandsDynamic Commands with Command ID Write User IDWrite Recipe Write Flush Sequence Read User ID Write Fluid Control ModeRead Flush Sequence Read RecipeRead Fluid Control Mode Yymmdd Read Job InfoExample Ascii Character String Decode Algorithm Read Alarm InfoYymmdddw Read Event Info Flow Control System Home Screen Run Mode ScreensOpening Screen See Advanced Screen 1, page 82, to set Home Screen Key Description DetailsKey Description Key Description Spray Screen Spray Screen, in Standby ModeFill Screen, Color a Selected Fill ScreenUsage Screen Usage ScreenEvents Screen Errors ScreenJobs Screen Password Screen Setup Mode ScreensSystem Screen Mix Pressure Tolerance Mix Idle TimeoutMix No Flow Timeout Low Flow TimeoutHose Length and Diameter Gun Hose LengthGun Hose Diameter Mix At WallGateway ID EnableManual Override Gun Trigger SignalFlow Control Setpoint Signal Fluid ControlRecipe Screen Flush Screen Pump Screen Default Settings Not Selected Default Settings SelectedPump Screen 3, Pressure Monitoring Disabled Pressure Alarm and Deviation LimitsCalibrate Screen Calibration ScreensVolume Check Screen Enter Measured Volume of Solvent Maintenance Screen Maintenance ScreensMaintenance Screen 4, Color Valve Resets Advanced Screen Download Depth Enable USB Downloads/UploadsLog 90% Full Advisory Enabled Display UnitsPerform the pressure check Calibration ChecksPump Pressure Check Pump Volume Check Scroll to Calibrate Screen 3, Solvent Meter CalibrationMultiple Color Systems Color ChangeSingle Color Systems Gun Trigger Input Function System ErrorsTo Clear Error and Restart Mix Errors Code Type Description Problem Cause Solution Error CodesPurge Errors Code Type Description Problem Cause Solution Pumping Errors Code Type Description Problem Cause Solution EBH# Code Type Description Problem Cause SolutionSAD1 Pressure Errors Code Type Description Problem Cause Solution Qbdx QadxCAC# System Errors Code Type Description Problem Cause SolutionEmix CA0XCddx CagxCDC# USB Errors Code Type Description Problem Cause Solution Wxuu WxudUSB B9SX B9AXB9BX ENT# Calibration Errors Code Type Name DescriptionEND# ENS0Code Type Name Description Maintenance ErrorsFlushing MaintenancePreventive Maintenance Schedule Cleaning the ADMPositive Displacement Metric Proportioner Technical DataFor Graco Canada Customers Graco Standard WarrantyGraco Information