Calibration Checks

Calibration Checks

Pump Pressure Check

NOTE: Enter the transducer calibration data before doing the pressure check.

Perform the pressure check:

The first time the system is operated.

Whenever new materials are used in the system, especially if the materials have viscosities that differ significantly.

At least once per month as part of regular maintenance.

Whenever a pump is serviced or replaced.

During each pressure test, the dose valve will close during an up stroke and a down stroke (in either order). This test is to verify that the valves are seating properly and not leaking. If leaking occurs, the system will alarm after the test for that particular pump direction.

NOTE: Do not trigger the spray device during the pressure check.

1.The pump and lines must be primed with color or catalyst before doing the Pressure Check. See Prime and Fill the System, page 20.

2.If the display is on a Run Mode screen, press

to access setup screens.

3.Scroll to Calibrate to display Calibrate Screen 1, page 77.

4.Press the Pressure Check button for the desired pump. The pump will build pressure in the line to a minimum of the Stall Test Pressure. The pump will then move to the center stroke position and stall test the upstroke, followed by the downstroke.

5.The pressure and flow that the unit measured are displayed on the screen. Compare with the maximum leak rate entered on System Screen 2, page 68. If the values are substantially different, repeat the test.

NOTE: The stall test pressure set point is a minimum. The system may stall at a higher pressure depending on hose lengths and fluid composition.

84

332564B

Image 84
Contents Important Safety Instructions ProMix PD2K Proportioner for Automatic Spray ApplicationsContents Related Manuals Manual No DescriptionManual No Models ECB Labels0359 Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Important Isocyanate ISO Information Isocyanate ConditionsKeep Components a and B Separate Moisture Sensitivity of IsocyanatesGeneral Information USB Download Procedure Advanced Display Module ADMADM Display USB Upload Procedure ADM Keys and Indicators ADM Keys and Indicators FunctionSoft Key Icons Soft Key FunctionsKey Function Key Function Navigating the Screens Screen IconsPre-operation Checklist Power OnPre-Operation Tasks Initial System Setup Flush Before Using EquipmentValve Settings Without Color Change With Color ChangeOperation Using Automatic Display Module ADM Prime and Fill the SystemSpraying Purging Flush Mixed MaterialShutdown Flush the SystemSingle Color System Color Change SystemOperation Using a Programmable Logic Controller PLC Network Communications and Discrete I/ODiscrete I/O PD2K Discrete I/O ConnectionsDigital Inputs Analog InputsDiscrete I/O Connections on Efcm KEYCommunication Gateway Module CGM Details CGM OverviewCGM Kits Output Register 00 Current System Mode Number Operation Mode DescriptionNetwork Communication I/O Data Map ProMix PD2K Network OutputsOutput Registers 01, 02, 03, and 04 Pump Status Pump States for Output Registers Description BerOutput Register 05 Actual Mix Flow Output Register 06 Actual Mix RatioOutput Register 14 Active Recipe Potlife Timeout Set Point Output Register 27 Safety Interlock Input StatusOutput Registers 28 36 DCS Command Structure Output Register 12 Active Recipe Material B Flush SequenceOutput Register 37 Time Output Register 38 40 Software VersionOperation Using a Programmable Logic Controller PLC Network Output Data Map Read Only NonePSI = Busy = ACK= NAK = ERRInput Register 00 System Mode Command ProMix PD2K Network InputsInput Register 02 Flush/Prime Pump Command Input Register 03 Mix Pump 1 Control Set PointInput Register 07 Go to Recipe Number Input Register 08 Clear Active Alarm Input Registers 14 21 DCS Command StructureInput Register 09 Job Complete Input Register 10 Gun 1 TriggerOperation Using a Programmable Logic Controller PLC Network Input Data Map Write/Read 40180 Gun 3 Trigger Uint32 Operation Flow Charts Purge Mode SequenceFlush Pump Command Inactive Pump Flush and Prime SequencesColor Change Sequence ChangeMixing Sequence Standby Mix Ready? noAlarm Clearing Sequence Clear Active AlarmNetwork Communication Dynamic Command Structure DCS Dynamic Command DescriptionList of DCS Commands Dynamic Commands with Command IDWrite User ID DCSWrite Recipe Write Flush Sequence Write Fluid Control Mode Read User IDRead Recipe Read Flush SequenceRead Fluid Control Mode Read Job Info YymmddRead Alarm Info YymmdddwExample Ascii Character String Decode Algorithm Read Event Info Flow Control System Run Mode Screens Opening ScreenHome Screen Home Screen Key Description Details See Advanced Screen 1, page 82, to setKey Description Key Description Spray Screen, in Standby Mode Spray ScreenFill Screen Fill Screen, Color a SelectedUsage Screen Usage ScreenErrors Screen Jobs ScreenEvents Screen Setup Mode Screens Password ScreenSystem Screen Mix Idle Timeout Mix No Flow TimeoutLow Flow Timeout Mix Pressure ToleranceGun Hose Length Gun Hose DiameterMix At Wall Hose Length and DiameterEnable Gateway IDGun Trigger Signal Flow Control Setpoint SignalFluid Control Manual OverrideRecipe Screen Flush Screen Pump Screen Default Settings Selected Default Settings Not SelectedPressure Alarm and Deviation Limits Pump Screen 3, Pressure Monitoring DisabledCalibration Screens Calibrate ScreenVolume Check Screen Enter Measured Volume of Solvent Maintenance Screens Maintenance ScreenMaintenance Screen 4, Color Valve Resets Advanced Screen Enable USB Downloads/Uploads Log 90% Full Advisory EnabledDisplay Units Download DepthCalibration Checks Pump Pressure CheckPerform the pressure check Pump Volume Check Solvent Meter Calibration Scroll to Calibrate Screen 3,Color Change Single Color SystemsMultiple Color Systems System Errors To Clear Error and RestartGun Trigger Input Function Error Codes Purge Errors Code Type Description Problem Cause SolutionMix Errors Code Type Description Problem Cause Solution Pumping Errors Code Type Description Problem Cause Solution Code Type Description Problem Cause Solution EBH#SAD1 Pressure Errors Code Type Description Problem Cause Solution Qadx QbdxSystem Errors Code Type Description Problem Cause Solution EmixCA0X CAC#Cagx CDC#Cddx USB Errors Code Type Description Problem Cause Solution Wxud USBWxuu B9AX B9BXB9SX Calibration Errors Code Type Name Description END#ENS0 ENT#Maintenance Errors Code Type Name DescriptionMaintenance Preventive Maintenance ScheduleCleaning the ADM FlushingTechnical Data Positive Displacement Metric ProportionerGraco Standard Warranty Graco InformationFor Graco Canada Customers