4.Remove the screws that secure the brass contactor mounting plate to the back of the electrical box, then pull the contactors out to access the gray tab shown in Figure 7. Pull outward on the gray tab to release each contactor from the mounting plate.
Mounting Plate
Gray Tab
Figure 7. Contactor release tab location.
5.Install the two 110V contactors from the Model G0705 110V Conversion Kit in place of the contactors you removed in Step 4.
6.Replace the wires you removed in Step 3 to the corresponding terminals on the 110V con- tactors. The wiring is the same for 110V and 220V. Refer to SECTION 8: WIRING starting on Page 45 for detailed wiring diagrams.
7.Locate the indicator lamp shown in Figures 4 & 5. Disconnect the two wires from its termi- nals, then remove the lamp.
8.Install the 110V indicator lamp from the Model G0705 110V Conversion Kit in place of the lamp you removed in Step 7.
9.Connect the wires you removed in Step 7 to the corresponding terminals on the 110V indi- cator lamp. The wiring is the same for 110V and 220V.
Model G0705 (Mfg. since 09/09)
10.Locate the terminal block located in the motor junction box, shown in Figure 8.
Motor 220V
Terminal Block
110V Terminal Block Jumper Position. (Wire positions are the same for 110V/220V)
U1 | Z2 | Run |
| U1 | Z2 |
| Start |
| W2 | Capacitor | U2 |
| W2 |
| Capacitor |
| 20 MFD | V1 | V2 | 150 MFD | |||
V1 | U2 |
| U2 | ||||
|
| 450 VAC |
|
|
|
| 250 VAC |
Z1 |
|
|
|
|
|
|
|
|
|
| V1 |
|
| U1 |
|
W1 |
|
|
| W1 | V2 |
|
|
PE | Ground |
|
|
|
|
|
|
|
Jumpers Moved |
| 220V | Jumper |
|
| |
|
|
| ||||
for 110V |
| Location |
|
| ||
|
|
| ||||
|
|
| ||||
|
|
|
|
|
|
|