SECTION 6 − SETUP AND OPERATION
6-1. Safety Equipment
1 | 2 | Wear the | following during | |
operation: |
| |||
|
|
| ||
|
| 1 | Dry, Insulating Gloves | |
|
| 2 | Safety Glasses With Side | |
|
|
| Shields |
|
DO NOT wear rings or watches during operation.
sb3.1* 1/94
6-2. System Description
The ProHeat 35 Induction Heating Power Source is designed to function either as an
A special identifier, embedded within the extension cable connector, provides the means for the power source to configure itself by recognizing the type of extension cable(s) attached to its output connectors.
Designed to provide a single level of output (up to 35 kW), the ProHeat 35 power source has two panel mounted connectors that are connected in parallel to the power source output. This design allows the system to operate with either a single output extension cable or two output extension cables.
If a single output extension cable is used, a protective plug (provided with the system) MUST be placed on the unused output connector or the system will not operate. If two output extension cables are used, they both MUST be of the same type (either both
The ProHeat 35 is intelligent to the point that it will automatically adjust output power levels if internal system operating parameters or internal tempera- tures reach or exceed specific set limits (see Section 9).
6-3. Power Source/System Setup
To view the System Setup screen, simultaneously press the Parameters
on the display:
| kW | and Program | buttons and the following screen will appear | |
| V | A | ||
| Hz | |||
|
|
|
| |
|
|
|
|
|
System Setup Screen | ||
Degree Units: >_F |
| SYSTEM SETUP |
Tolerance...: ±25 | Backlight: Yes | |
Input Type..: K TC | Control | Mode: Manual |
Power Output: 35 KW | System | Lock: No |
To change a setting:
S | Press the Cursor | button to move the cursor to the parameter to be changed |
SPress Increase
or Decrease button to select desired