Soak Function
When type is set to Soak, the following screen appears on the display:
| Custom Program Screen |
Mode | : Custom Program |
Segment.... | : 1 |
Type | :>Soak |
Soak Time..: 00:01:00
Use the Cursor | button to move the cursor to the Soak Time position and use the Increase |
the desired value. |
|
or Decrease button to set
When the cursor is in the Soak Time position, pressing the Cursor | button again automatically advances the program to the next segment |
number. |
|
End Function
When type is set to End, the following screen appears on the display:
| Custom Program Screen |
Mode | : Custom Program |
Segment.... | :> 2 |
Type | : End |
Control TC.: 1
The only changeable parameter in the End segment is selecting the number of thermocouples. Use the Cursor | button to move the cursor |
to the Control TC position. Press the Increase or Decrease button to select the number of control thermocouples to be used for
the program. Selections are as follows: 1, 1,2, 1,2,3, or 1,2,3,4. TC1 MUST always be a control thermocouple. TC2 thru TC4 can be used for controlling or monitoring. When a thermocouple is selected as control, the LED adjacent to the
A custom program can contain up to 10 segments. To view Program parameters, position the cursor at segment and use the Increase
or
Decrease button to advance through the segment numbers until the End segment. When a segment number is changed, appropriate segment parameter information appears on the display.