Miller Electric ProHeat 35 manual SOCKET/WRENCH Selection Table Standard Metric

Page 69

Notes

SOCKET/WRENCH SELECTION TABLE

 

SOCKET/WRENCH SELECTION TABLE

 

(U.S. STANDARD)

 

 

 

(METRIC)

 

 

 

 

 

 

 

 

 

 

Specifications

Socket or Wrench Size

 

Specifications

Socket or Wrench Size

 

 

 

 

 

 

 

 

 

Bolt

Decimal

Bolt

Nut

 

Bolt

U.S.

 

 

 

Decimal

Bolt

Nut

Diameter

Equivalent

 

Diameter

 

 

 

Equivalent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4 in

.250 in

3/8 in

7/16 in

 

6 mm

.2362 in

10 mm

10 mm

 

 

 

 

 

 

 

 

 

5/16 in

.3125 in

1/2 in

9/16 in

 

8 mm

.3150 in

14 mm

14 mm

 

 

 

 

 

 

 

 

 

3/8 in

.375 in

9/16 in

5/8 in

 

10 mm

.3937 in

17 mm

17 mm

 

 

 

 

 

 

 

 

 

7/16 in

.4375 in

5/8 in

3/4 in

 

12 mm

.4724 in

19 mm

19 mm

 

 

 

 

 

 

 

 

 

1/2 in

.500 in

3/4 in

13/16 in

 

14 mm

.5512 in

22 mm

22 mm

 

 

 

 

 

 

 

 

 

9/16 in

.5625 in

7/8 in

7/8 in

 

16 mm

.6299 in

24 mm

24 mm

 

 

 

 

 

 

 

 

 

5/8 in

.625 in

15/16 in

1 in

 

18 mm

.7087 in

27 mm

27 mm

 

 

 

 

 

 

 

 

 

3/4 in

.750 in

1-1/8 in

1-1/8 in

 

22 mm

.8661 in

32 mm

32 mm

 

 

 

 

 

 

 

 

 

7/8 in

.875 in

1-5/16 in

1-5/16 in

 

24 mm

.9449 in

36 mm

36 mm

 

 

 

 

 

 

 

 

 

1 in

1.000 in

1-1/2 in

1-1/2 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OM-222 166 Page 63

Image 69
Contents OM-222 166K 2007−11 Processes DescriptionFile Induction Heating From Miller to You Table of Contents Routine Maintenance Blowing Out Inside Of Unit − MaintenanceLimit Conditions Limit Condition Codes Fault Conditions EMF InformationDirectives StandardsDecstat1/07 Page Induction Heating Hazards Symbol UsageElectric Shock can kill Fumes and Gases can be hazardousCalifornia Proposition 65 Warnings About Implanted Medical Devices Principal Safety Standards EMF Information− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUNE Décharge Électrique peut entraîner la mort LES Fumées ET LES GAZ peuvent être dangereuxLE Chauffage PAR Induction peut provoquer des brûlures Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresProposition californienne 65 Avertissements Principales normes de sécurité Information EMFEn ce qui concerne les implants médicaux − Definitions Power before working on Shown by the symbolsAre possible hazards as KillWeee Label For Products Sold Within The EU Rating Label For CE ProductsSymbols And Definitions − InstallationSpecifications I1maxSelecting a Location Do not move or operate unit where it could tipTipping Movement Location And AirflowPhase Input Voltage Electrical Service Guide50 Hz Three Min Grounding Conductor Size In AWGWelding Power Source Input Power Connections Connecting 3-Phase Input Power For 460/575 Volt ModelsDisconnect Device Input Power Connections GND/PE Earth GroundConnecting 3-Phase Input Power For 400/460 Volt Models Power Source Output Connections Remote 14 Receptacle RC14 Information and Connections Remote 14 Socket InformationSocket Socket Information Signal Common Temperature Recorder Socket InformationSocket No Socket Information UnusedReceptacles Plug Secondary Insulation ProtectionHandle Magnet Workpiece Use handle to place magnet on the workpieceLocating Thermocouples Volt AC Duplex Receptacle And Supplementary ProtectorOther end is fitted with a 2-pin type K connector Attaching Welded Thermocouples Do not weld thermocouples while connected to power sourcePlacing Temperature Probe Using Contact ThermocouplesControls − Components and ControlsSafety Equipment − Setup and OperationPower Source/System Setup System DescriptionOM-222 166 Mode....... Preheat Control TC Temperature Soak Time Temperature-Based ControlDecrease button to change the value to the desired setting ProgrammingPwht Post-Weld Heat Treat Bake-OutCustom Program Soak ParametersEnd Custom ProgramType.......Step 600Number OM-222 166 Ramp Temperature 600 Ramp Rate 600 /HrSoak Function SoakNumber End FunctionManual Control Typical 5-Segment Custom ProgramSoak at 1250 degrees F for a period Run Status Temperature Based ControlTC5 Target Temp −−−− TC6 Countdown.. −−−−−− Preheat, Bake-Out And Pwht Run Status ScreenParameters Power TC5 Current TC6 Voltage Frequency KHzCooler Cooler cannot be turned off while output is onMust be running to enter Hold mode Real-Time OperationProgram run is initiated, the Run Button. a change of program parameters Power Source Output Characteristics System Operating CharacteristicsAir Cooled Output Liquid Cooled OutputRoutine Maintenance − MaintenanceDisconnect power Before maintainingServicing Hazards − Safety Precautions for ServicingCalifornia Proposition 65 Warnings Operator Interface Indicators − Diagnostics & TroubleshootingLimit Condition Codes Limit ConditionsRun Status Limit Condition Additional InformationFault Conditions Fault Condition CodesFault Condition Additional Information System Diagnostic Screens Off Cable1 LQD DIAG1 OutI1 Cable2 LQD OutI2 ClntFR 0.75 GPMClrSts Flowing Therm2 Therm1Therm3 VBusTurn Off welding power source, and disconnect input power Removing Wrapper and Measuring Input Capacitor VoltageTools Needed 16, 3/8 Blowing Out Inside Of Unit Material Thickness Reference ChartCircuit Diagram − Electrical Diagram218 057-G See Figure 11-313 11-2 − Parts ListFront Panel Rear Panel Base w/Components Top Windtunnel Capacitor Assembly Right Windtunnel 229 Right Windtunnel 400 V Model Only 208 Left Windtunnel PLG14 10. Hermaphroditic Blank Plug Assy SOCKET/WRENCH Selection Table Standard Metric OM-222 166 Service Your distributor also givesSupport Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s