SOPEN − no cable or plug in place
ClntFR − This is the coolant flow rate (in GPM) from the cooler on a
ClrSts − This is the status of the cooler. Possible labels:
SOff
SFlowing
The second diagnostic screen is available by again pressing and holding the Run Status | button and pressing the Parameters |
button.
kW V HzA
|
| System Diagnostic Screen |
|
| |
VLnA−B: 460V | Therm1: | 75 |
| DIAG2 | |
VLnB−C: 460V | Therm2: | 75 | Therm5: OPEN | ||
VLnC−A: | 460V | Therm3: | 75 | ClrTmp: | 77 |
VBus: | 650V | Therm4: OPEN | RmtFlw: | Off |
VBus − This is the DC bus voltage.
Therm1 − This is the temperature of the current source primary heatsink.
Therm2 − This is the temperature of the bridge heatsink.
Therm3 − This the the temperature of the current source secondary heatsink.
Therm4 − Open (not used).
Therm5 − Open (not used).
ClrTmp − This is the temperature of the coolant on a
SOPEN − no cooler is detected.
RmtFlw − This is the status of the relay contacts for remote coolant flow on a
SOFF
SON
.RmtFlw feature is unsupported on the current platform.