TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDER- STAND INSTRUCTION MANUAL.
responding cutters such as are listed in the Festool catalogues.
The user is liable for damages
and injuries due to incorrect usage.
Technical data
Power | 12 A |
Voltage | ~ 120 V, 60 Hz |
No load speed | 10000 - 22500 rpm |
Quick height adjustment | 70 mm (2.76“) |
Fine height adjustment | 8 mm (0.31“) |
Router diameter, max. | 63 mm |
Drive shaft connection of | |
the spindle | M 22x1 |
Weight | 4.5 kg (9.9 lbs) |
Protection class | / II |
| Symbols |
V | Volts |
A | Amperes |
Hz | Hertz |
~ | Alternating current |
n0 | No load speed |
| Class II Construction |
rpm Revolutions or reciprocation per minute
ØDiameter
Functional description
The pictures for the functional description are on a
1.1Speed controller
1.2Locking button
1.3On/Off switch
1.4Scale
1.5Spindle stop
1.6Pivoted turret stop
1.7Collet nut
Use for intended purpose
The routers are designed for routing wood, plastics and similar materials. Aluminium and plasterboard can also be processed with cor-
Electrical connection
The network voltage must conform to the voltage indicated on the rating plate. A 16 A safety fuse (for 120 V) or a corresponding protective
See the following figure for connection and disconnection of the power cable.
Always switch the machine off before connecting or disconnecting the power cable!
2 |
Extension cable
If an extension cable is required, it must have a sufficient
Total Extension Cord | 25 | 50 | 100 | 150 |
Lenght (feed) |
|
|
|
|
Cord size (AWG) | 16 | 14 | 12 | 10 |
|
|
|
|
|
Note: The lower the AWG number, the stron- ger the cable.
Switching the ma-
chine on and off
Keep the machine steady dur- ing switching and during use by holding the handles (3.1, 3.4) with both hands.
Switch (3.3) serves as an On/Off switch. It may be latched with the locking knob on the side (3.2) for continuous operation. Pressing the switch again releases the lock.
6