HP 2103R-CSDI manual If the NV SEL DIP switch is

Page 35

Configuring DIP Switches

2-11

If the NV SEL DIP switch is:

ON (enabled) – The Edge Router module uses configuration settings stored in its NVRAM. If NVRAM does not contain configuration settings, the Edge Router modules are assigned to the Isolate_1 network.

OFF (disabled) – The Edge Router module uses DIP switch settings.

Selecting a Network

In an unmanaged ONcore hub, the DIP switches determine the network setting (unless NVRAM configuration settings are enabled).

1 To select a network:

Set the switches according to Table 2-5.

Table 2-5 ONcore Network Selection DIP Switch Settings

 

Switch Settings

 

 

Network

 

 

 

 

 

 

 

 

Selection

CH SEL 0

CH SEL 1

CH SEL 2

CH SEL 3

 

 

 

 

 

Ethernet_1

ON

ON

ON

ON

(default)

 

 

 

 

 

 

 

 

 

Ethernet_2

OFF

ON

ON

ON

 

 

 

 

 

Ethernet_3

ON

OFF

ON

ON

 

 

 

 

 

Ethernet_4

OFF

OFF

ON

ON

 

 

 

 

 

Ethernet_5

ON

ON

OFF

ON

 

 

 

 

 

Ethernet_6

OFF

ON

OFF

ON

 

 

 

 

 

Ethernet_7

ON

OFF

OFF

ON

 

 

 

 

 

Ethernet_8

OFF

OFF

OFF

ON

 

 

 

 

 

Isolate_1

ON

ON

ON

OFF

 

 

 

 

 

Isolate_2

OFF

ON

ON

OFF

 

 

 

 

 

Isolate_3

ON

OFF

ON

OFF

 

 

 

 

 

Isolate_4

OFF

OFF

ON

OFF

 

 

 

 

 

Switch combinations not listed in Table 2-5 select Isolate_1.

2Disable NVRAM by setting the NV SEL DIP switch to the off position.

Image 35
Contents Edge Router Module Installation Guide For Ethernet 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Iii Page Contents Configuring the Edge Router Module Monitoring Edge Router Module Operation Index Limited Warranty Audience How to Use This GuideAbout this Guide IntroductionList conventions used throughout this guide ConventionsCommands Cisco Documents RelatedDocuments 3Com DocumentsInternational and Hughes LAN Systems, May Page Introduction LAN Product Overview Shows the architecture of each Edge Router module type Including Module FeaturesEdge Router IP/IPX Edge Router Module Features Ethernet LAN Edge Router Module Memory Configurations Feature Set Desktop Memory Type Page Installing the Edge Router Module Configure the Edge Router module InstallationFlowchart Router module PrecautionaryProcedures Quick InstallationCisco Systems Getting Started Guide Quick Installation Unpacking Edge Router Module Installation Guide for EthernetPlug Positions Verifying JumperSwitches Configuring DIPIsolating the ONline Edge Router Module ConfiguringONcore Carrier DIP Parameters Switches Enabling or Disabling Nvram Configuration Shows the ONcore carrier DIP switch locationTo select a network Set the switches according to Table If the NV SEL DIP switch isRouter Module InstallingIf you are installing ONline EdgeThis is called a hot swap To install the Edge Router module in an ONcore hubONcore Edge Installing the Edge Router Module in an ONcore Hub Opened and Closed Module Ejectors Close the ejectors FigurePage Router Module Overview ConfigurationManaged Terminal Attaching aManagement Hub Selecting a Network Saving the ConfigurationThis section contains the following topics ConfiguringCarrier in a Managed ONcoreCarrier Default Settings Configuring the Carrier in a Managed ONcore Hub DMM DIP Nvram DIP Terminal to Auxiliary port Console Port Attaching a Terminal Cable to the Console Port Mini-DIN connector pinouts are provided in Appendix a Page Operation Module OperationMonitoring Edge Edge Router Module LEDs Each LED is described in Table Following network management module commandsShowing Module StatusModule Command Syntax for the Show Module command is Using the ShowONline show module 6 verbose Edge Router module installed in slot 1 of an ONcore hub Port Command Ports Syntax for the Show Port command isONcore show port Page Troubleshooting Troubleshooting Troubleshooting Network Connectivity Problems Problems Malfunctions CorrectingOperating MalfunctionsSeconds, and then power it on Specifications Electrical General SpecificationsMechanical Specifications Environmental Specifications5006C-FT OpenHub Management Cable has a Cables when you install all equipmentCable Pinouts OpenHub Management Cable Part Number OHPMGT-CABDTR CTS TXD CTS Cable Pinouts DTE DCE Ltst CS+ SCTE+ Table A-17 X.21 DTE and DCE Cable Pinouts DB-15 15 Pin Days a week, 24 hours a day ServicesOnline Technical Through the following online systems408 Access by Digital ModemPress Return to view the 3ComForum main menu Supplier Support FromYour Network Corporation U.S. and Canada, call 800 876-3266 for customer serviceTo find your authorized service provider 3ComContacting 3Com ISD Technical Publications Accessing the 3Com ISD MIBTo exit the FTP session, invoke the quit command Numerics IndexQuick Software 1-8Upgrading Firmware 1-8 memory Page Limited Warranty 408 764-5000 3/18/96