HP sv6 manual Configuration, Boot Up

Page 42

installation and user information

installation process

4.Configuration

For hp visualization center sv6 configurations, follow these procedures:

Table 2-6

Boot up

BOOT AND CONFIGURE THE MASTER

 

SYSTEM BEFORE BOOTING THE SLAVE

 

SYSTEMS. Have a list of hostnames and IP

 

addresses to assign to the systems so they will be

 

visible on your site’s network. Run

 

set_parms addl_netwrk

 

to set the master’s network information.

 

Optional: Set up networking and root passwords

 

on slave nodes using:

 

/var/opt/ignite/sps/sv6files/sv_config

 

See the “How to Use hp visualization center sv6

 

Tools” section for more information on sv_config.

 

 

Specify Compositor serial port

If possible, leave the Compositor connected to the

 

default port on the master workstation (serial port

 

2, /dev/tty1p0). If you wish to move the

 

Compositor to a different port, this change must be

 

specified in the /etc/X11/X0screens file.

 

 

Configure system software

When each computer comes up, it can be

 

customized for the local environment (networking

 

info, user accounts, passwords, etc.) Ensure that all

 

systems are compatible with your working

 

environment before moving to the next step.

 

 

5.Boot Up

NOTE

BOOT AND CONFIGURE THE MASTER SYSTEM BEFORE

 

BOOTING THE SLAVE SYSTEMS.

 

• The boot console on the master will prompt you for a

 

 

hostname, an IP address and other system and network

 

settings.

 

• After you have answered all of the startup questions, power

 

on all of the other workstations and network switchboxes.

42

Chapter 2

Image 42
Contents Installation and user’s guide Manufacturing Part Number A6062-90005 Edition E0302Legal notices Copyright noticesHp product warranty statement Printing historyHP Product Duration of Warranty For additional information Viewing documentation on the recovery CD UserguidesContents file configuration Projector calibration targets Hp scalable visualization digital compositorHp mini-sv6 configuration Regulatory informationGlossary Contents Safety and support information How to obtain support for your sv6 system How to obtain support for your sv6 system Safety warnings Rack stabilityPower distribution units PDUs Sample Power Distribution Unit PDUElectric shock, connect each component to a grounded outlet Power Distribution Unit PDU, there may be a risk of highCable and Plugs Between the PDU and the Wall Receptacle Only. Never operate any component with its ground pinPDU power limitations Metallic particulate contaminationNema 5-15 Receptacle Safety warnings Installation and user information Document purpose Section descriptionsDocument purpose Product overview Hp visualization centers sv6 j6700 and mini-sv6 b2600 Hp visualization center sv6 components Pipe system configuration Arrangement of the hardware in the racks may varySingle Display Channel Multiple Display Channels Hp visualization center sv6 architecture Pipe System ArchitectureAccelerate Mode Vertical slice, Horizonal slice and Grid Hp visualization center sv6 operating modesAccumulate Mode Each fraction of the screen is called a screen rectangleMixed Mode Mixed Mode 16-Pipe Example Supported configurationsHardware Configurations Three or Four 3D Pipes Per ChannelSeven or Eight 3D Pipes Per Channel Software configurations Sixteen 3D Pipes Per ChannelSoftware not supported Installation and user information Installation process AssessmentPreparation for wide field displays TIPAnti-Tip Plate Hp visualization center sv6 installationRack see -10 when systems are being set up Over. The anti-tip plate should remain deployed. See the hpConnect Power, I/O Devices Position console monitors12 Connecting Compositor to Monitor or Other Display Device 13 Connecting HP ProCurve Hub to LAN Boot Up ConfigurationSpecify Compositor Serial Port Optional Configure System SoftwareVerification Do not use any other options with -testConfigure ds2100 Run Your Application Software setup specifications How to determine your current version Updating softwareMaintain current graphics patches Installation Steps Uninstallation steps Installing to all sv6 systems using HP Software Distributor Preparation Copy and register locally Which kills the remaining swinstall GUI windows When installing patches that require a reboot, switch to aVersions, either login remotely to perform the install, or Start install GUI swinstallVerification Example march gb patch OK OKAdvanced setup for multiple display channels Additional X serverMaster Hostname Svmc1 Configuring offset overlap Additional equipmentEdge Blending Configuring offset overlap for multiple rows19 Height Edge Blending Width Column Row Backdrops 3840 x 1024 3x1280 x 21 3072 x 768 3x1024 xX0screens Description UsageServer This file must be edited as root and must be locatedChanging resolution Standard ResolutionsCustomized Resolutions Stereo ResolutionsHow to use hp visualization center sv6 tools Xadvsetpipes GUI Description Examples How to use hp visualization center sv6 tools Jitter file tool Sv6 diagnostics DescriptionOptions Sample output from running sv6diag on a standard sv6 system Chapter Stereoscopic viewing Active stereo overviewPassive stereo overview Unpack and inventory components Stereo hardware installationEnsure eye wear is functioning and clean Position emitter in viewing areaAdd ScreenOption Changing to stereo monitor modePower up the emitters Start up the new X server initVerification Simple stereoscopic applicationApplication suggestions Using NFS to mount hard drivesOptimization Optimizing performance23 Panes Y offset adjustments Use the xadvsetpipes tool see 24 X and Y Offset Adjustments Method #1 Accumulate Mode SeeOptimizing image quality Method #2Pass through mode Gamma correction in pass through mode Pass through mode on a multi-channel sv6Invokes the application Gamma value Hpoglpush Environmentfile configuration file configuration For networking to function properly, hostnames used #/etc/inittab Init4initdefault OPERATINGSYSTEM=HP-UX LOOPBACKADRESS=127.0.0.1 INTERFACESTATE1= DHCPENABLE1=0 Projector calibration targets How to use projector calibration targets How to use projector calibration targetsHpcirc.pm 128x128 circles tiled example shown Hpline.pm 64X64 grid lines tiled example shown 64 x 64 grids for horizontal and vertical convergenceHpgray.pm gray scale tiled example shown Hpeye1.pm eye chart #1 tiled example shown Hpcolor.pm color scale tiled example shownHpeye2.pm eye chart #2 tiled example shown Hp scalable visualization digital Compositor cards Compositor cardsFigure A-1 Compositor Cards 100 Compositor parts list Table A-1Compositor configurations Table A-2Sv6 compositor frame delay This mode is invalid with passive stereo Procedure IntroductionInterface Testing output or input cards Testing controller cardsLED indicators Hp mini-sv6 configuration Mini-sv6 configuration Figure B-1 Mini sv6 configurationAppendix B 109 110 Regulatory information Appendix C Safety warning for the USA and Canada FCC radio frequency interference statement USA onlyNoise declaration for Germany Regulatory information 116 Glossary Active stereo Glossary 119 Screen real estate