HP sv6 manual Specify Compositor Serial Port Optional, Configure System Software

Page 43

installation and user information installation process

• Set up network information on the slave nodes.

At boot up, all installed graphics devices will be set to default mode - 1280x1024, 75Hz. See the “Changing Resolutions” section for details.

a. Specify Compositor Serial Port (Optional)

 

 

By default, the compositor is connected and configured on serial

 

 

port2 of the master 2D workstation(s). If you wish to move it to

 

 

port1, specify the serial port address in the

 

 

/etc/X11/X0screens file under the 'ScreenOptions' section:

 

 

ScreenOptions

 

 

SlsdCompositorSerialport /dev/ttyp0

 

b.

Configure System Software

 

 

• To alter any network settings not done during the initial

 

 

boot, log in to one system at a time and use set_parms

 

 

addl_netwrk

 

 

• Set the root password

 

 

— log in as root

 

 

— Type passwd

 

 

— Type in and verify new password

 

 

• Run HP’s System Administration Manager (SAM) to create

 

 

new logical volumes

 

 

• Add user accounts, passwords and other desktop

 

 

customizations settings.

 

 

If the configuration was successful, running your master

 

 

system at init level 3 or 4 (/etc/init 4) will bring up a Common

 

 

Desktop Environment (CDE) session across all of your

 

 

screens.

 

 

If a wide field display option is being installed with your

TIP

 

 

system, now is the time for configuration and calibration to

 

 

occur. Your chosen vendor may have additional software and

 

 

files required to set up these display systems. Consult the

 

 

display vendor for details.

 

 

 

Chapter 2

43

Image 43
Contents Manufacturing Part Number A6062-90005 Edition E0302 Installation and user’s guideCopyright notices Legal noticesPrinting history Hp product warranty statementHP Product Duration of Warranty For additional information Userguides Viewing documentation on the recovery CDContents Hp scalable visualization digital compositor file configuration Projector calibration targetsRegulatory information Hp mini-sv6 configurationGlossary Contents Safety and support information How to obtain support for your sv6 system How to obtain support for your sv6 system Rack stability Safety warningsSample Power Distribution Unit PDU Power distribution units PDUsOnly. Never operate any component with its ground pin Power Distribution Unit PDU, there may be a risk of highCable and Plugs Between the PDU and the Wall Receptacle Electric shock, connect each component to a grounded outletMetallic particulate contamination PDU power limitationsNema 5-15 Receptacle Safety warnings Installation and user information Section descriptions Document purposeDocument purpose Product overview Hp visualization centers sv6 j6700 and mini-sv6 b2600 Hp visualization center sv6 components Arrangement of the hardware in the racks may vary Pipe system configurationSingle Display Channel Multiple Display Channels Pipe System Architecture Hp visualization center sv6 architectureHp visualization center sv6 operating modes Accelerate Mode Vertical slice, Horizonal slice and GridEach fraction of the screen is called a screen rectangle Accumulate ModeMixed Mode Supported configurations Mixed Mode 16-Pipe ExampleThree or Four 3D Pipes Per Channel Hardware ConfigurationsSeven or Eight 3D Pipes Per Channel Sixteen 3D Pipes Per Channel Software configurationsSoftware not supported Installation and user information Assessment Installation processTIP Preparation for wide field displaysOver. The anti-tip plate should remain deployed. See the hp Hp visualization center sv6 installationRack see -10 when systems are being set up Anti-Tip PlatePosition console monitors Connect Power, I/O Devices12 Connecting Compositor to Monitor or Other Display Device 13 Connecting HP ProCurve Hub to LAN Configuration Boot UpConfigure System Software Specify Compositor Serial Port OptionalDo not use any other options with -test VerificationConfigure ds2100 Run Your Application Software setup specifications Updating software How to determine your current versionMaintain current graphics patches Installation Steps Uninstallation steps Installing to all sv6 systems using HP Software Distributor Preparation Copy and register locally Start install GUI swinstall When installing patches that require a reboot, switch to aVersions, either login remotely to perform the install, or Which kills the remaining swinstall GUI windowsExample march gb patch OK OK VerificationAdditional X server Advanced setup for multiple display channelsMaster Hostname Svmc1 Additional equipment Configuring offset overlapConfiguring offset overlap for multiple rows Edge Blending19 Height Edge Blending Width Column Row Backdrops 21 3072 x 768 3x1024 x 3840 x 1024 3x1280 xThis file must be edited as root and must be located UsageServer X0screens DescriptionStandard Resolutions Changing resolutionStereo Resolutions Customized ResolutionsHow to use hp visualization center sv6 tools Xadvsetpipes GUI Description Examples How to use hp visualization center sv6 tools Jitter file tool Description Sv6 diagnosticsOptions Sample output from running sv6diag on a standard sv6 system Chapter Active stereo overview Stereoscopic viewingPassive stereo overview Position emitter in viewing area Stereo hardware installationEnsure eye wear is functioning and clean Unpack and inventory componentsStart up the new X server init Changing to stereo monitor modePower up the emitters Add ScreenOptionSimple stereoscopic application VerificationOptimizing performance Using NFS to mount hard drivesOptimization Application suggestions23 Panes Y offset adjustments Use the xadvsetpipes tool see 24 X and Y Offset Adjustments Method #2 Accumulate Mode SeeOptimizing image quality Method #1Pass through mode Pass through mode on a multi-channel sv6 Gamma correction in pass through modeInvokes the application Hpoglpush Environment Gamma valuefile configuration file configuration For networking to function properly, hostnames used #/etc/inittab Init4initdefault OPERATINGSYSTEM=HP-UX LOOPBACKADRESS=127.0.0.1 INTERFACESTATE1= DHCPENABLE1=0 Projector calibration targets How to use projector calibration targets How to use projector calibration targetsHpcirc.pm 128x128 circles tiled example shown 64 x 64 grids for horizontal and vertical convergence Hpline.pm 64X64 grid lines tiled example shownHpgray.pm gray scale tiled example shown Hpcolor.pm color scale tiled example shown Hpeye1.pm eye chart #1 tiled example shownHpeye2.pm eye chart #2 tiled example shown Hp scalable visualization digital Compositor cards Compositor cardsFigure A-1 Compositor Cards 100 Table A-1 Compositor parts listTable A-2 Compositor configurationsSv6 compositor frame delay This mode is invalid with passive stereo Introduction ProcedureInterface Testing controller cards Testing output or input cardsLED indicators Hp mini-sv6 configuration Figure B-1 Mini sv6 configuration Mini-sv6 configurationAppendix B 109 110 Regulatory information Appendix C FCC radio frequency interference statement USA only Safety warning for the USA and CanadaNoise declaration for Germany Regulatory information 116 Glossary Active stereo Glossary 119 Screen real estate