HP sv6 manual Gamma value, Hpoglpush Environment

Page 84

installation and user information

optimization

gamma value

Another way to fine-tune the image quality is to adjust the gamma correction. Specify the default values to be used for 3D gamma correction. using the instructions in the

/opt/graphics/OpenGL/sv/doc/README.gamma file.

HPOGL_PUSH _ENVIRONMENT

To override the default environment specified in the SlaveEnvironment section of the /etc/X11/X0screens file, have the application startup script set HPOGL_PUSH_ENVIRONMENT.

By setting HPOGL_PUSH_ENVIRONMENT, all HPOGL* environment variables are passed across to the slave nodes. With this mechanism, each application can have its own individual environment. In the absence of HPOGL_PUSH_ENVIRONMENT, slave environments default to X0screens settings at the time that the Xserver was started.

As an example, assume X0screens has:

SlaveEnvironment

HPOGL_FORCE_SCENEAA=1

HPOGL_LIGHTING_SPACE=EC

Application abc’s startup script contains:

export HPOGL_BOUNDING_VOLUME_ENABLE=1

export HPOGL_BOUNDING_VOLUME_GLOBAL=1

export HPOGL_BVOL_MIN_VERTS=5

export HPOGL_BVOL_MAX_VERTS=10

export HPOGL_PUSH_ENVIRONMENT=1

/opt/apps/abc

For this example, application abc will run with the four variables set in its environment and WILL NOT have HPOGL_FORCE_SCENEAA or HPOGL_LIGHTING_SPACE=EC set.

Any other application that is run without

HPOGL_PUSH_ENVIRONMENT will have only the X0screens values.

84

Chapter 2

Image 84
Contents Installation and user’s guide Manufacturing Part Number A6062-90005 Edition E0302Legal notices Copyright noticesHp product warranty statement Printing historyHP Product Duration of Warranty For additional information Viewing documentation on the recovery CD UserguidesContents file configuration Projector calibration targets Hp scalable visualization digital compositorHp mini-sv6 configuration Regulatory informationGlossary Contents Safety and support information How to obtain support for your sv6 system How to obtain support for your sv6 system Safety warnings Rack stabilityPower distribution units PDUs Sample Power Distribution Unit PDUPower Distribution Unit PDU, there may be a risk of high Cable and Plugs Between the PDU and the Wall ReceptacleElectric shock, connect each component to a grounded outlet Only. Never operate any component with its ground pinPDU power limitations Metallic particulate contaminationNema 5-15 Receptacle Safety warnings Installation and user information Document purpose Section descriptionsDocument purpose Product overview Hp visualization centers sv6 j6700 and mini-sv6 b2600 Hp visualization center sv6 components Pipe system configuration Arrangement of the hardware in the racks may varySingle Display Channel Multiple Display Channels Hp visualization center sv6 architecture Pipe System ArchitectureAccelerate Mode Vertical slice, Horizonal slice and Grid Hp visualization center sv6 operating modesAccumulate Mode Each fraction of the screen is called a screen rectangleMixed Mode Mixed Mode 16-Pipe Example Supported configurationsHardware Configurations Three or Four 3D Pipes Per ChannelSeven or Eight 3D Pipes Per Channel Software configurations Sixteen 3D Pipes Per ChannelSoftware not supported Installation and user information Installation process AssessmentPreparation for wide field displays TIPHp visualization center sv6 installation Rack see -10 when systems are being set upAnti-Tip Plate Over. The anti-tip plate should remain deployed. See the hpConnect Power, I/O Devices Position console monitors12 Connecting Compositor to Monitor or Other Display Device 13 Connecting HP ProCurve Hub to LAN Boot Up ConfigurationSpecify Compositor Serial Port Optional Configure System SoftwareVerification Do not use any other options with -testConfigure ds2100 Run Your Application Software setup specifications How to determine your current version Updating softwareMaintain current graphics patches Installation Steps Uninstallation steps Installing to all sv6 systems using HP Software Distributor Preparation Copy and register locally When installing patches that require a reboot, switch to a Versions, either login remotely to perform the install, orWhich kills the remaining swinstall GUI windows Start install GUI swinstallVerification Example march gb patch OK OKAdvanced setup for multiple display channels Additional X serverMaster Hostname Svmc1 Configuring offset overlap Additional equipmentEdge Blending Configuring offset overlap for multiple rows19 Height Edge Blending Width Column Row Backdrops 3840 x 1024 3x1280 x 21 3072 x 768 3x1024 xUsage ServerX0screens Description This file must be edited as root and must be locatedChanging resolution Standard ResolutionsCustomized Resolutions Stereo ResolutionsHow to use hp visualization center sv6 tools Xadvsetpipes GUI Description Examples How to use hp visualization center sv6 tools Jitter file tool Sv6 diagnostics DescriptionOptions Sample output from running sv6diag on a standard sv6 system Chapter Stereoscopic viewing Active stereo overviewPassive stereo overview Stereo hardware installation Ensure eye wear is functioning and cleanUnpack and inventory components Position emitter in viewing areaChanging to stereo monitor mode Power up the emittersAdd ScreenOption Start up the new X server initVerification Simple stereoscopic applicationUsing NFS to mount hard drives OptimizationApplication suggestions Optimizing performance23 Panes Y offset adjustments Use the xadvsetpipes tool see 24 X and Y Offset Adjustments Accumulate Mode See Optimizing image quality Method #1 Method #2Pass through mode Gamma correction in pass through mode Pass through mode on a multi-channel sv6Invokes the application Gamma value Hpoglpush Environmentfile configuration file configuration For networking to function properly, hostnames used #/etc/inittab Init4initdefault OPERATINGSYSTEM=HP-UX LOOPBACKADRESS=127.0.0.1 INTERFACESTATE1= DHCPENABLE1=0 Projector calibration targets How to use projector calibration targets How to use projector calibration targetsHpcirc.pm 128x128 circles tiled example shown Hpline.pm 64X64 grid lines tiled example shown 64 x 64 grids for horizontal and vertical convergenceHpgray.pm gray scale tiled example shown Hpeye1.pm eye chart #1 tiled example shown Hpcolor.pm color scale tiled example shownHpeye2.pm eye chart #2 tiled example shown Hp scalable visualization digital Compositor cards Compositor cardsFigure A-1 Compositor Cards 100 Compositor parts list Table A-1Compositor configurations Table A-2Sv6 compositor frame delay This mode is invalid with passive stereo Procedure IntroductionInterface Testing output or input cards Testing controller cardsLED indicators Hp mini-sv6 configuration Mini-sv6 configuration Figure B-1 Mini sv6 configurationAppendix B 109 110 Regulatory information Appendix C Safety warning for the USA and Canada FCC radio frequency interference statement USA onlyNoise declaration for Germany Regulatory information 116 Glossary Active stereo Glossary 119 Screen real estate