HP sv6 manual Introduction, Interface, Procedure

Page 105

hp scalable visualization digital compositor

compositor self-test sequence

compositor self-test sequence

introduction

All compositor cards are assumed to be fully functional before they are installed in a compositor chassis. They are all individually and functionally tested at the manufacturer. Once they are installed in the compositor backplane, however, they could fail by not being seated properly or by having bent bus pins. This test is a check of backplane connections to ensure that they are functional. This test is simply pass / fail, with the only feedback being which card failed.

interface

This test uses the standard serial communications to the Field Programmable Gate Arrays (FGPA) on the controller card. Both controller FPGAs have registers allowing the controller to read the data values on the video data bus input pins. One of the two FPGAs also has the ability to drive a test value onto its video data bus output.

procedure

This test is performed as part of the compositor initialization on power-up. First, the controller steps through all of the slots on the backplane, identifying the card type. At this point. invalid configurations are identified. Invalid configurations consist of configurations that have an output card with no card before it or an input card that has no card after it.

If the configuration is valid, then all cards are programmed. Card programming is verified by a successful serial transfer to each FPGA after programming. If a card fails the serial transfer test, it is identified as a failure. If one or more FPGA fails the serial transfer test, compositor initialization is aborted, and the failing cards are identified.

The ability of the cards to be configured and then communicate, tests all of the control signals to the cards. The video data bus remains to be tested. The controller tests these signals by instructing each FPGA to drive a specific bit pattern onto the video data bus, using the bus test registers. These test values are then read by the following I/O cards, and

Appendix A

105

Image 105
Contents Manufacturing Part Number A6062-90005 Edition E0302 Installation and user’s guideCopyright notices Legal noticesPrinting history Hp product warranty statementHP Product Duration of Warranty For additional information Userguides Viewing documentation on the recovery CDContents Hp scalable visualization digital compositor file configuration Projector calibration targetsHp mini-sv6 configuration Regulatory informationGlossary Contents Safety and support information How to obtain support for your sv6 system How to obtain support for your sv6 system Rack stability Safety warningsSample Power Distribution Unit PDU Power distribution units PDUsCable and Plugs Between the PDU and the Wall Receptacle Power Distribution Unit PDU, there may be a risk of highElectric shock, connect each component to a grounded outlet Only. Never operate any component with its ground pinPDU power limitations Metallic particulate contaminationNema 5-15 Receptacle Safety warnings Installation and user information Section descriptions Document purposeDocument purpose Product overview Hp visualization centers sv6 j6700 and mini-sv6 b2600 Hp visualization center sv6 components Arrangement of the hardware in the racks may vary Pipe system configurationSingle Display Channel Multiple Display Channels Pipe System Architecture Hp visualization center sv6 architectureHp visualization center sv6 operating modes Accelerate Mode Vertical slice, Horizonal slice and GridEach fraction of the screen is called a screen rectangle Accumulate ModeMixed Mode Supported configurations Mixed Mode 16-Pipe ExampleHardware Configurations Three or Four 3D Pipes Per ChannelSeven or Eight 3D Pipes Per Channel Software configurations Sixteen 3D Pipes Per ChannelSoftware not supported Installation and user information Assessment Installation processTIP Preparation for wide field displaysRack see -10 when systems are being set up Hp visualization center sv6 installationAnti-Tip Plate Over. The anti-tip plate should remain deployed. See the hpPosition console monitors Connect Power, I/O Devices12 Connecting Compositor to Monitor or Other Display Device 13 Connecting HP ProCurve Hub to LAN Configuration Boot UpConfigure System Software Specify Compositor Serial Port OptionalVerification Do not use any other options with -testConfigure ds2100 Run Your Application Software setup specifications How to determine your current version Updating softwareMaintain current graphics patches Installation Steps Uninstallation steps Installing to all sv6 systems using HP Software Distributor Preparation Copy and register locally Versions, either login remotely to perform the install, or When installing patches that require a reboot, switch to aWhich kills the remaining swinstall GUI windows Start install GUI swinstallExample march gb patch OK OK VerificationAdditional X server Advanced setup for multiple display channelsMaster Hostname Svmc1 Additional equipment Configuring offset overlapConfiguring offset overlap for multiple rows Edge Blending19 Height Edge Blending Width Column Row Backdrops 21 3072 x 768 3x1024 x 3840 x 1024 3x1280 xServer UsageX0screens Description This file must be edited as root and must be locatedStandard Resolutions Changing resolutionStereo Resolutions Customized ResolutionsHow to use hp visualization center sv6 tools Xadvsetpipes GUI Description Examples How to use hp visualization center sv6 tools Jitter file tool Sv6 diagnostics DescriptionOptions Sample output from running sv6diag on a standard sv6 system Chapter Stereoscopic viewing Active stereo overviewPassive stereo overview Ensure eye wear is functioning and clean Stereo hardware installationUnpack and inventory components Position emitter in viewing areaPower up the emitters Changing to stereo monitor modeAdd ScreenOption Start up the new X server initSimple stereoscopic application VerificationOptimization Using NFS to mount hard drivesApplication suggestions Optimizing performance23 Panes Y offset adjustments Use the xadvsetpipes tool see 24 X and Y Offset Adjustments Optimizing image quality Accumulate Mode SeeMethod #1 Method #2Pass through mode Gamma correction in pass through mode Pass through mode on a multi-channel sv6Invokes the application Hpoglpush Environment Gamma valuefile configuration file configuration For networking to function properly, hostnames used #/etc/inittab Init4initdefault OPERATINGSYSTEM=HP-UX LOOPBACKADRESS=127.0.0.1 INTERFACESTATE1= DHCPENABLE1=0 Projector calibration targets How to use projector calibration targets How to use projector calibration targetsHpcirc.pm 128x128 circles tiled example shown Hpline.pm 64X64 grid lines tiled example shown 64 x 64 grids for horizontal and vertical convergenceHpgray.pm gray scale tiled example shown Hpcolor.pm color scale tiled example shown Hpeye1.pm eye chart #1 tiled example shownHpeye2.pm eye chart #2 tiled example shown Hp scalable visualization digital Compositor cards Compositor cardsFigure A-1 Compositor Cards 100 Table A-1 Compositor parts listTable A-2 Compositor configurationsSv6 compositor frame delay This mode is invalid with passive stereo Procedure IntroductionInterface Testing output or input cards Testing controller cardsLED indicators Hp mini-sv6 configuration Figure B-1 Mini sv6 configuration Mini-sv6 configurationAppendix B 109 110 Regulatory information Appendix C FCC radio frequency interference statement USA only Safety warning for the USA and CanadaNoise declaration for Germany Regulatory information 116 Glossary Active stereo Glossary 119 Screen real estate