HP sv6 manual Glossary 119

Page 119

master mode - This is the workstation where the master X server is run to control all other rendering via the workstations assigned to do 3D rendering (slave nodes). This system also does all of the 2D rendering for the entire screen.

mixed mode - In this hp visualization center sv6 operating mode, the screen is divided among the 3D slaves for accelerate mode, but multiple workstations are assigned to render each subdivision for accumulate mode. This results in both improved rendering performance and image quality.

mini-sv6-Single channel systems with 3 or 7 slave rendering nodes. A second graphics card in the master sytem is used as the fourth or eighth 3D render node. Since there are fewer j-class workstations, both the cost and performance are lower than on standard 4-pipe or 8-pipe configurations.

module - The card inside the hp ProCurve Switch. Also known as a ‘blade’. The official product name is the hp ProCurve 100Base-T Gigabit LAN Module.

panes - This is a setpipes screen rectangle layout that assigns four large screen rectangles to form a border around the center of the screen. This allows for a greater amount of the hp visualization center sv6’s resources to be focused on rendering to the center where the most intense rendering demands are. The center of the screen can be sub-divided by grid, horizontal slices or vertical slices. The result of using this layout is faster rendering performance.

passive stereo - Stereo capability where no emitter is need. Uses a combination of polarized glasses and special output display devices (i.e. specially aligned projectors or

glossary

screen -

passive stereo work bench displays). The glasses filter out the correct image for the right and left eye. Two output cards must be used for the compositor to produce the entire left-eye scene and entire right-eye scene.

PDU - Power Distribution Unit on the rack. Use these special power strips to plug-in racked hardware.

pipe - A graphics enabled workstation. Usually refers to a 3D slave node that is rendering all or part of the screen.

pipe rectangle - A sub-division of the entire display. Each of the areas receives output from the group of 3D pipes assigned to render to it. Select a layout using /opt/graphics/OpenGL/sv/bin/setpipes or the GUIs. Also known as a screen rectangle.

real estate - Describes the continuous screen space spanning across multiple display devices.

sample - In accumulate mode, each graphics device is used to produce a slightly jittered sample of the entire screen. The compositor, to produce a higher quality image, then averages those samples together

scalability - hp visualization center sv6 is scalable in the sense that configurations with larger numbers of can achieve higher levels of performance and image quality. In the case of the multiple display HP visualization centers, more real-estate is achieved.

screen - The area to which the entirety of the output is sent. This can span more than one monitor and be fed by more than one graphics device.

Glossary

119

Image 119
Contents Manufacturing Part Number A6062-90005 Edition E0302 Installation and user’s guideCopyright notices Legal noticesPrinting history Hp product warranty statementHP Product Duration of Warranty For additional information Userguides Viewing documentation on the recovery CDContents Hp scalable visualization digital compositor file configuration Projector calibration targetsGlossary Hp mini-sv6 configurationRegulatory information Contents Safety and support information How to obtain support for your sv6 system How to obtain support for your sv6 system Rack stability Safety warningsSample Power Distribution Unit PDU Power distribution units PDUsOnly. Never operate any component with its ground pin Power Distribution Unit PDU, there may be a risk of highCable and Plugs Between the PDU and the Wall Receptacle Electric shock, connect each component to a grounded outletNema 5-15 Receptacle PDU power limitationsMetallic particulate contamination Safety warnings Installation and user information Section descriptions Document purposeDocument purpose Product overview Hp visualization centers sv6 j6700 and mini-sv6 b2600 Hp visualization center sv6 components Arrangement of the hardware in the racks may vary Pipe system configurationSingle Display Channel Multiple Display Channels Pipe System Architecture Hp visualization center sv6 architectureHp visualization center sv6 operating modes Accelerate Mode Vertical slice, Horizonal slice and GridEach fraction of the screen is called a screen rectangle Accumulate ModeMixed Mode Supported configurations Mixed Mode 16-Pipe ExampleSeven or Eight 3D Pipes Per Channel Hardware ConfigurationsThree or Four 3D Pipes Per Channel Software not supported Software configurationsSixteen 3D Pipes Per Channel Installation and user information Assessment Installation processTIP Preparation for wide field displaysOver. The anti-tip plate should remain deployed. See the hp Hp visualization center sv6 installationRack see -10 when systems are being set up Anti-Tip PlatePosition console monitors Connect Power, I/O Devices12 Connecting Compositor to Monitor or Other Display Device 13 Connecting HP ProCurve Hub to LAN Configuration Boot UpConfigure System Software Specify Compositor Serial Port OptionalConfigure ds2100 VerificationDo not use any other options with -test Run Your Application Software setup specifications Maintain current graphics patches How to determine your current versionUpdating software Installation Steps Uninstallation steps Installing to all sv6 systems using HP Software Distributor Preparation Copy and register locally Start install GUI swinstall When installing patches that require a reboot, switch to aVersions, either login remotely to perform the install, or Which kills the remaining swinstall GUI windowsExample march gb patch OK OK VerificationAdditional X server Advanced setup for multiple display channelsMaster Hostname Svmc1 Additional equipment Configuring offset overlapConfiguring offset overlap for multiple rows Edge Blending19 Height Edge Blending Width Column Row Backdrops 21 3072 x 768 3x1024 x 3840 x 1024 3x1280 xThis file must be edited as root and must be located UsageServer X0screens DescriptionStandard Resolutions Changing resolutionStereo Resolutions Customized ResolutionsHow to use hp visualization center sv6 tools Xadvsetpipes GUI Description Examples How to use hp visualization center sv6 tools Jitter file tool Options Sv6 diagnosticsDescription Sample output from running sv6diag on a standard sv6 system Chapter Passive stereo overview Stereoscopic viewingActive stereo overview Position emitter in viewing area Stereo hardware installationEnsure eye wear is functioning and clean Unpack and inventory componentsStart up the new X server init Changing to stereo monitor modePower up the emitters Add ScreenOptionSimple stereoscopic application VerificationOptimizing performance Using NFS to mount hard drivesOptimization Application suggestions23 Panes Y offset adjustments Use the xadvsetpipes tool see 24 X and Y Offset Adjustments Method #2 Accumulate Mode SeeOptimizing image quality Method #1Pass through mode Invokes the application Gamma correction in pass through modePass through mode on a multi-channel sv6 Hpoglpush Environment Gamma valuefile configuration file configuration For networking to function properly, hostnames used #/etc/inittab Init4initdefault OPERATINGSYSTEM=HP-UX LOOPBACKADRESS=127.0.0.1 INTERFACESTATE1= DHCPENABLE1=0 Projector calibration targets How to use projector calibration targets How to use projector calibration targetsHpcirc.pm 128x128 circles tiled example shown Hpgray.pm gray scale tiled example shown Hpline.pm 64X64 grid lines tiled example shown64 x 64 grids for horizontal and vertical convergence Hpcolor.pm color scale tiled example shown Hpeye1.pm eye chart #1 tiled example shownHpeye2.pm eye chart #2 tiled example shown Hp scalable visualization digital Compositor cards Compositor cardsFigure A-1 Compositor Cards 100 Table A-1 Compositor parts listTable A-2 Compositor configurationsSv6 compositor frame delay This mode is invalid with passive stereo Interface ProcedureIntroduction LED indicators Testing output or input cardsTesting controller cards Hp mini-sv6 configuration Figure B-1 Mini sv6 configuration Mini-sv6 configurationAppendix B 109 110 Regulatory information Appendix C FCC radio frequency interference statement USA only Safety warning for the USA and CanadaNoise declaration for Germany Regulatory information 116 Glossary Active stereo Glossary 119 Screen real estate