Troubleshooting: Wiring

ABS/ATC WIRING

CAB ECU Wiring Harness Connectors

The in-cab EC-60controllers are designed to interface with AMP MCP 2.8 connectors as referenced in Chart 4. Follow all AMP requirements for the repair of wire harnesses.

All wire harness connectors must be properly seated. The use of secondary locks is strongly advised.

CAUTION: All unused ECU connectors must be covered and receive proper environmental protection.

Frame ECU Wiring Harness Connectors

Frame-mount EC-60controllers are designed to interface with Deutsch connectors as referenced in Chart 4.

CAUTION: The frame wire harness connectors must be properly seated with the seals intact (undamaged). All unused connector terminals must be plugged with the appropriate sealing plugs. Failure to properly seat or seal the connectors could result in moisture or corrosion damage to the connector terminals. ECUs damaged by moisture and/or corrosion are not covered under the Bendix warranty. Secondary locks must be snapped securely in place.

Follow all Deutsch requirements for the repair of wire harnesses.

CAUTION: All unused connector terminals must be plugged with the appropriate sealing plugs.

Frame ECU Connector Covers

Frame ECUs are provided with covers that must be removed to permit connection of the vehicle wiring harness. The cover can be removed by sliding the slide lock mechanism to the unlock position.

The covers provide strain relief and connector protection of the vehicle wire harness and will accept round convoluted conduit with an I.D. of 19 mm.

ABS Wiring Requirements

As a matter of good practice and to insure maximum system robustness, always use the maximum size wire supported by the wire harness connectors for battery, ignition, ground, PMV, TCV, Interaxle Differential Lock and indicator lamp circuits.

All sensor and serial communications circuits (J1587 and J1939) must use twisted pair wiring (one to two twists per inch). See the appropriate SAE document for additional details.

WARNING: All wires must be carefully routed to avoid contact with rotating elements. Wiring must be properly secured approximately every 6 to 12 inches using UV stabilized, non-metallic hose clamps or bow-tie cable ties to prevent pinching, binding or fraying.

It is recommended that wires be routed straight out of a connector for a minimum of three inches before the wire is allowed to bend.

Battery and ground wires should be kept to a minimum length.

If convoluted tubing is used, its I.D. must match the size of the wire bundle as closely as possible.

CAUTION: Wire harness lengths must be carefully selected for the vehicle. Harnesses that are too long increase the possibility of electrical interference and wire damage. Excess lengths of wire are not to be wound to form coils, instead re-route, repair or replace wire harness. Do not attempt to stretch harnesses that are too short, since mechanical strain can result in wire breakage.

32

Image 32
Contents Introduction Standard Frame Standard Cab Premium Frame Premium CabComponents ECU MountingCab ECUs Frame ECUsEC-60CONTROLLER Inputs Hardware ConfigurationsEC-60CONTROLLERS with PLC EC-60CONTROLLER Outputs POWER-UP Sequence ABS Operation ATC Operation Optional ATC Off-Road Mode Dynamometer Test ModeEngine Torque Limiting ETL with Smart ATC Traction Control Bendix Smart ATC Traction ControlABS Partial Shutdown ECU Reconfiguration Reconfiguring EC-60ControllersSystem Configuration Troubleshooting General Safe Maintenance PracticesRemoving the EC-60CONTROLLER Assembly Installing a NEW EC-60CONTROLLERBlink Codes Troubleshooting Blink Codes and Diagnostic ModesECU Diagnostics Diagnostic Modes Diagnostic ModesActive Diagnostic Trouble Code Mode Inactive Diagnostic Trouble Code ModeReconfigure ECU Mode Clearing Active Diagnostic Trouble CodesSystem Configuration Check Mode Using HAND-HELD or PC-BASED Diagnostics Bendix RDU Remote Diagnostic UnitFeatures of the Bendix RDU Tool Bendix RDU Reset FunctionBendix ACom Diagnostics 3.0 Software Bendix RDU Communication ProblemsNexiq Bendix Application Card Bendix Technical Assistance TeamActive or Inactive Diagnostic Trouble Codes 1st Blink Code Go Here for Troubleshooting Tests NumberTroubleshooting Diagnostic Trouble Codes 2nd Diagnostic Blink Trouble CodeWheel Speed Sensors Code DescriptionCab-mount ECU Looking into wire harness connector Frame-mount ECU Looking into wire harness connectorConnector Pin Speed Sensor Repair TestsPressure Modulator Valves Connector Pin PMV Location Pressure Modulator Valve Repair TestsTraction Control Valves Traction Control Valve Repair TestsConnector Pin Power Supply Test Troubleshooting Diagnostic Trouble Codes Power SupplyPower Supply Tests J1939 Troubleshooting Tests Connector Pin J1939Connector Pin J1939 J1939 Low J1939 HighECU Repair Information Troubleshooting Diagnostic Trouble Codes Miscellaneous2nd. Diagnostic Blink Trouble Code Code Description Miscellaneous Troubleshooting ABS Indicator LampRetarder Relay PMV CommonsNot Used Standard Cab X1 Connector Pin AssignmentsStandard Cab X2 Connector Pin Assignments Standard Frame X1 Connector Pin Assignments Standard Frame X2 Connector Pin AssignmentsPremium Cab X1 Connector Pin Assignments Premium Cab X2 Connector Pin AssignmentsPremium Cab X3 Connector Pin Assignments Premium Cab Model EC-60ControllerPremium Frame X3 Connector Pin Assignments Premium Frame X1 Connector Pin AssignmentsPremium Frame X2 Connector Pin Assignments Troubleshooting Wiring ABS/ATC WiringTerminal ABS Component Connector Wire Wire Seal TerminalPlug Lock Crimp Tool Troubleshooting Wiring Wheel Speed Sensor WiringTroubleshooting Standard Cab Wiring Schematic 4S/4M Drive Axle Steer AxleTroubleshooting Premium Cab Wiring Schematic 6S/6M Packard BPin CPin APinTroubleshooting Premium Cab Wiring Schematic 6S/5M Packard Pin B Pin C Pin aTroubleshooting Standard Frame Wiring Schematic 4S/4M Steer Axle Drive AxleTroubleshooting Premium Frame Wiring Schematic 6S/6M Premium Frame Wiring Schematic 6S/6MTroubleshooting Premium Frame Wiring Schematic 6S/5M Premium Frame Wiring Schematic 6S/5MGlossary SID FMI General J1587 J1587 Equivalents