Raypak 1005 operating instructions Controls, Termination using Adapter Thimble

Page 32

Fig. 32: Adapter Thimble

Crimp end to be installed into termination cap.

Fig. 33: Termination using Adapter Thimble

Controls

WARNING: Installation, adjustment and service of heater controls, including timing of various operating functions, must be performed by a qualified installer, service agency or the gas supplier. Failure to do so may result in control damage, heater malfunction, property damage, personal injury, or death.

WARNING: Turn off the power to the heater before installation, adjustment or service of any heater controls. Failure to do so may result in board damage, heater malfunction, property damage, personal injury, or death.

CAUTION: This appliance has provisions to be connected to more than one supply source. To reduce the risk of electric shock, disconnect all such connections before servicing.

CAUTION: Risk of electric shock: More than one disconnect switch may be required to de-energize the equipment before servicing.

The Raypak modulating temperature control is pro- vided to maintain the desired system water temperature. The control has various modes of opera- tion which are described on the following pages.

The XTherm is designed for use with Primary/Secondary pumping only, utilizing integral injector pumps to maintain proper flows and tempera- tures in the heater.

Setpoint: The intended system supply temperature.

Deadband: Deadband is a band of temperature sens- ing where no action occurs. All temperature controllers have a deadband and the purpose is to prevent short- cycling of the heater. The on-board temperature controller has a deadband of 2ºF around the differen- tial.

Differential: A heat source must be operated with a temperature differential in order to prevent short- cycling. The temperature differential is divided around the “target” temperature or set-point. The Call For Heat (CFH) contact will close in the controller when the water temperature is below the target temperature by 1/2 of the differential setting, and will open when the water temperature is above the target temperature by 1/2 of the differential setting. See Fig. 34.

32

Image 32
Contents Installation & Operating Instructions Page Contents Pay Attention to These Terms Before Installation Installations at ElevationProduct Receipt Model IdentificationComponent Locations General InformationGas Vent Size Conn Input Max MinWater Time to Produce Serious Temp Burn General SafetyTime/Temperature Relationships in Scalds Installation Installation CodesIndoor Installations Equipment BaseOutdoor Installations Combustion and Ventilation AirIndoor Units Heater Min. Clearance Minimum From CombustibleTable E Vent/Air Inlet Termination Clearances Combustion Air Filter Direct VentTruSeal Combustion Air Remove the Debris ScreenInstallations Canadian InstallationsConventional Combustion Air Supply All Air from Inside the BuildingRelief Valve Installation and Piping Temperature & Pressure GaugeWater Piping GeneralHydronic Heating Domestic Hot Water Fitting Type Equivalent Length ft 2 NPTAutomatic Chlorinators and Chemical Feeders Combined Potable Water and Space HeatingPool Heating Pool/Spa Water Chemistry Winterizing Your HeaterWater Hardness Gas SupplyGas Supply Connection Electrical Power Connections Gas Supply PressureCheck the Power Source Making the Electrical ConnectionsAppliance Categories Field Wiring ConnectionSupport of Vent Stack Installations Vent Terminal LocationVenting Installation Tips Venting ConfigurationsCanadian Installations InstallationCertified Total Effective Combustion Air Air InletLength Max. Length* ftModel Vent Size Volume Flue Products Common VentingHorizontal Through-the-Wall and Direct Venting Category Horizontal Through-the-Wall VentingDirect Vent-Vertical Direct Vent VerticalOutdoor Installation Outdoor VentingCleaning PVC vent assembly instructionsFreeze Protection PVC Venting OptionPVC Vent Adapter Termination using Adapter Thimble ControlsOperating Modes Differential GraphBoil Target 78F Boil Max 86F Boil Min 70F ‘Burner’ Delay 10 VDC 20 mA Boiler Target Modes Default Setting Range10 VDC 20 mA Definitions Rank Number Field Type Fault DescriptionOperation Heater Sequence of Operation Ignition ModuleHigh Limit-Manual Reset High Limit-Auto Reset OptionalFlow Switch Code ConditionLow Water Cut-Off Optional Modulating Temperature ControlHigh & Low Gas Pressure Switches Optional Air Pressure Switch UDB Diagnostic BoardBlocked Vent Switch Condensate Float SwitchWiring Diagrams Models 1005 Model Pre Start-up Check START-UPPre Start-up Initial Start-up PreparationStart-Up Required toolsModel No Net Blower Suction Setting In. WC Model No Amp Draw SettingBlower Check Manifold CheckSafety Inspection Leak Test Procedure Dual-Seat Gas ValveFinishing Follow-UpPost Start-Up Check GASTo Turn Off Gas To Appliance OperationLighting Instructions Troubleshooting StepSuggested Minimum Maintenance Schedule MaintenanceUDB Fault History Preventive Maintenance Schedule PeriodicallyWeekly Semi-AnnuallyAs Required AppendixInside Air Contamination Important Instructions for the Commonwealth of Massachusetts Limited Parts Warranty Xtherm Types H and WH ModelsLimited Parts Warranty Xtherm Types WHP START-UP Checklist for FAN-ASSISTED Raypak Products Page
Related manuals
Manual 12 pages 19.26 Kb

1005 specifications

Raypak is a prominent name in the heating industry, known for its innovative and efficient heating solutions for residential and commercial applications. The models 2005, 1005, and 1505 are notable offerings from Raypak, each designed to provide reliable performance, energy efficiency, and user-friendly operation.

The Raypak 2005 model stands out for its robust construction and high efficiency. It utilizes advanced technology to ensure consistent heating and reliability. With a high-capacity output, the 2005 is ideal for larger pools and spa applications, efficiently maintaining desired temperatures even during colder months. Its digital control system allows for precise temperature settings, enabling users to customize their heating needs effectively.

The 1005 model is an excellent choice for medium-sized pools and spas, offering a perfect balance of power and energy efficiency. One of its key features is the ability to operate quietly, making it suitable for residential areas where noise can be a concern. The 1005 employs a reliable gas burning system that maximizes fuel efficiency and provides fast heating. Its compact design also makes it easy to install, saving space while delivering exceptional performance.

The Raypak 1505 model is designed for versatility, catering to a wide range of heating requirements. One of its standout characteristics is its corrosion-resistant heat exchanger, which ensures long-lasting performance even in harsh environments. The 1505 also incorporates a user-friendly digital interface, allowing for easy operation and monitoring of temperature settings. It supports both natural gas and propane, providing flexibility to users based on their energy source preferences.

All three models—the 2005, 1005, and 1505—benefit from Raypak's commitment to energy efficiency. They are designed to meet stringent environmental standards while minimizing operational costs for the user. Additionally, their reliable safety features, such as pressure switches and safety valves, ensure safe operation across various conditions.

In summary, Raypak's 2005, 1005, and 1505 models exhibit a combination of efficiency, durability, and user-friendliness. With their advanced technologies and adaptable designs, these heaters are suitable for a wide array of heating applications, providing users with reliable solutions for their heating needs. Whether for residential or commercial use, Raypak's commitment to quality and innovation makes these models excellent choices for anyone seeking dependable heating solutions.