GE 2800 manual Quick Reference, ALL Units Require Power Connection KIT

Page 2

Quick Reference

Full Specs on pages 54 and 55

ALL UNITS REQUIRE POWER CONNECTION KIT

Power Connection Kit determines resistance heat output 7000 Btuh units do not activate 5 KW resistance heater

2800 Series Cooling with Electric Heat

MODEL

COOLING

EER

NUMBER

(Btuh)

 

AZ28E07DA*

7100/6900

12.7/12.7

AZ28E09DA*

9300/8900

12.0/12.0

AZ28E12DA*

11800/11500

11.5/11.5

AZ28E15DA*

14600/14300

10.2/10.2

AZ28E07EA*

7100

12.7

AZ28E09EA*

9000

12.0

AZ28E12EA*

11700

11.5

AZ28E15EA*

14600

10.2

Dry Air 25

2800 Series Cooling with Electric Heat

MODEL

COOLING

EER

NUMBER

(Btuh)

 

AZ28E07DAP

6800/6600

12.1/12.1

AZ28E09DAP

8600/8400

11.5/11.5

AZ28E12DAP

11200/11000

11.0/11.0

AZ28E07EAP

6800

12.1

AZ28E09EAP

8600

11.5

AZ28E12EAP

11200

11.0

3800 Series Heat Pump with Backup Electric Heat

MODEL

COOLING

EER

Reverse Cycle

COP

 

NUMBER

(Btuh)

BTUH

 

 

 

 

 

 

 

 

 

 

AZ38H07DA*

7100/6900

12.7/12.7

6400/6200

3.6/3.6

 

AZ38H09DA*

9000/8800

12.0/12.0

8400/8200

3.6/3.6

 

AZ38H12DA*

11700/11500

11.5/11.5

10900/10700

3.4/3.4

 

AZ38H15DA*

14600/14300

10.0/10.0

13400/13200

3.2/3.2

 

AZ38H07EA*

7100

12.7

6400

3.6

 

AZ38H09EA*

9000

12.0

8400

3.6

2800 and 3800 Series

AZ38H12EA*

11700

11.5

10900

3.4

 

 

 

 

 

Control Panel

AZ38H15EA*

14600

10.0

13400

3.2

5800 Series Heat Pump with Backup Electric Heat

MODEL

COOLING

EER

Reverse Cycle

COP

NUMBER

(Btuh)

BTUH

 

 

 

 

 

 

 

AZ58H07DA*

7200/7000

13.0/13.0

6400/6200

3.7/3.7

AZ58H09DA*

9300/9050

12.0/12.0

8400/8200

3.6/3.8

AZ58H12DA*

11800/11600

11.7/11.7

10900/10700

3.4/3.4

AZ58H15DA*

14700/14400

10.3/10.3

13800/13800

3.2/3.2

AZ58H07EA*

7300

13.0

6400

3.7

AZ58H09EA*

9300

12.0

8400

3.6

AZ58H12EA*

11800

11.7

10900

3.4

AZ58H15EA*

14700

10.3

13800

3.2

5800 Series Control Panel

*Dual rated 230/208-volt units are shown with ratings separated by “/”. Units with single rating are 265-volt units.

2

Image 2
Contents GE Zoneline packaged terminal air conditioners ALL Units Require Power Connection KIT Quick ReferenceExample Power Connection KitsZoneline Chassis Nomenclature Comparison of DRY AIR 25 Dehumidification Deluxe Dry Air 25 ModelsNewest Innovation from GE Cooling With Resistance HeatTable of Contents Introduction Chassis Room Cabinet Optional Accessories of the Zoneline SystemZoneline System Wall Case5800 Zoneline Features2800 .2Features and Benefits Compressor Restart Delay Fan-Only Setting HIGH/LOWFan-Cycle Switch SmartFan Electronic Temperature LimitingConcealed Manual Vent Control Easy Clean Air Discharge AreaUp-Front Air Filters Corrosion Protection OptionalHeating Temperature Limits Auxiliary Control SwitchesCooling Temperature Limits Series Switches Description Left SwitchesSeries models only Heat Sentinel Diagnostics Switch Up resistance heat onlyImportant CDC Comments all series applicable CDC Terminal Location and Typical WiringCentral Desk Control Resistance Heat Models Field Wiring TerminalRemote Thermostat Control RAK806 Universal Control Cover Label24V AC Feature Heat Pump Electric HeatHeat Pump Models Compressor Heater Common GroundField-Supplied Relay Specifications For Use With Mechanical 4-Wire Systems OnlyRemote Control Low Voltage Wiring Relay DesignationHeat Pumps and Energy Savings Balance PointHeat pump defrost Zoneline 3800 and 5800 Series Heat Pump Operation Zoneline 3800 and 5800 SeriesZoneline Heat Pump Heat Source Logic Heat pump condensateApplication Comments Air DistributionRAB71A Wall Case DimensionsWall Case with Chassis Installed RAB77 Wall CaseChoice of wall cases is available for the Zoneline Wall CaseSub-Base Wall Case Installation Data GeneralMasonry Wall Construction Architectural Window Louver InstallationWindow, Curtain and Panel Wall Construction Brick, Frame, Stucco Shingle ConstructionPreparation of the Wall Case for All Types of Construction Case AnglesBrick Veneer and Frame Construction Framing for Wall CaseFastening Wall Case Frame and Brick Veneer Installation Cord set connected Wall Section Detailed Side View22-1/4 Four sides 22-1/4 Where it joinsGasket Caulk around Perimeter Wall case all 22-3/842-1/8 Power supplyAll four sides where it 27-1/4 13-1/813-3/4 + D 4 ± 1/4RAB71/77 Ge.com TOP View RAK204 Series SUB-BASE Installation and Electrical Data RAB71/77 Wall CaseCondensate Disposal Systems Wall Case with RAD10 Drain KIT External Drain. See page 36 for internal drainInternal Drain. See page 35 for external drain Replacements of Existing Ducted Units Ducted InstallationsNew Ducted Installations Ducted Application ConsiderationsRAK601 Ducted Application AZ2800/3800 SeriesRAK6052 High WideDucted Detailed Side Views AZ2800/3800 Series Exterior Grilles Outdoor GrilleExterior Architectural Treatments Special Outdoor Grilles 230/208-Volt Permanently Connected Units Or 277-Volt Unit Installation Permanently Connected Units230/208-Volt Line-Cord Connected Units 230/208 Volt Sub-Base and Direct Connected UnitsEssential Elements Ordering Overview Electrical Wiring Information 2800/3800/5800 SeriesReplacement of Existing Chassis Volt Units Maximum Connected Load230/208-Volt Line Cord Connected Units Total Capacity Btuh Btuh at 80º F D.B. 67º F W.B Cooling Performance DataHeat Pump Performance Data 93.00 Indoor Ambient DB Temperature F 100Latent System Capacity Installed unit capacity Btuh Watts/KW Formula for Calculating Operating Costs Using Above DataOutdoor Design Temperature Difference Normal Yearly Operating DataPage Ge.com Typical 5800 Series Schematic Diagram Suggested Bid Form Specifications Suggested Bid Form Specifications Suggested Bid Form Specifications Receptacles/Sub-Bases Premium Line 5800 SeriesSpecifications Complete Accessory List RAB71AGeneral Installation Suggestions Replacement Installations Zoneline warrantyDucted Installation Comments New InstallationsWarm Gray Beige Maple Bittersweet Chocolate Alphabetical IndexExterior Grille Color Samples Century of quality and innovation GE Company Pub. No -S087 PC48947