Dimensions

RAB71A WALL CASE

A

- 13 3/4"

16"

42"

1/2" SQ. HOLE (2 REQ'D.)

 

 

2-3/4"

 

 

1-1/2" TYP

1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

5-5/8"

 

 

4"

ge.com

Additional

Wall Case Depths RAB7116 - 16" RAB7124 - 24" RAB7128 - 28" RAB7131 - 31"

WALL OPENING

16-1/4" MIN. x 42-1/4" MIN.

 

6"

21"

1/2" DIA.

36"

HOLE (3 REQ'D.)

 

RAB77 WALL CASE

42-1/8"

13-7/8"

2-7/8"

1-1/2"

1/2" SQ. HOLE

9/16"

 

 

5-5/8"

(2 REQ'D.)

 

16-1/4" 4"

WALL OPENING

 

 

 

 

6"

 

 

 

 

 

 

1/2" DIA.

 

 

19"

 

 

16-1/2" MIN. x 42-3/8" MIN.

 

 

 

 

(3 REQ'D.)

36"

 

 

 

 

 

 

 

 

 

 

WALL CASE WITH

CHASSIS INSTALLED

RAB71 = 13-3/4"

RAB77 = 13-7/8"

RAB71 = 42"

 

GRILLE

RAB71 = 20-7/8"

RAB77 = 42-1/8"

 

RAB77 = 21"

 

 

 

 

 

 

 

 

 

 

 

 

TOP VIEW

 

 

 

7-1/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIDE

 

 

 

 

 

 

 

VIEW

 

 

INSIDE

 

 

 

 

 

42"

 

ROOM

 

 

 

ROOM

 

 

 

 

 

 

 

 

 

CABINET

 

CABINET

 

 

 

GRILLE

RAB71 = 16" RAB77 = 16-1/4"

OUTSIDE

WALL CASE WITH SUB-BASE

 

 

FRONT VIEW*

 

 

 

 

 

13"

 

 

 

 

 

1-7/16"

3-1/2"

12-3/4"

12"

9-3/8"

2-1/2"

KNOCKOUTS (ENCLOSURE)

LEVELING SCREW

4 REAR; 4 BOTTOM

 

SEE PAGE 32 FOR KNOCKOUT LOCATION DIMENSIONS.

1-5/16"

3" MIN.

ADJUSTABLE TO 5" MAX.

SIDE VIEW

2-3/8" MIN.

INTERIOR

WALL

FINISHED FLOOR

*SHOWN WITH ACCESS COVERS REMOVED.

NOTE: CAUTION - REMOVE KNOCKOUTS FROM INSIDE OUT.

Installation Instructions Packed With Wall Case . . . See Page 25 For Additional Information Concerning Outdoor Weather Panel and Case Stiffener.

21

Image 21
Contents GE Zoneline packaged terminal air conditioners Quick Reference ALL Units Require Power Connection KITPower Connection Kits Zoneline Chassis NomenclatureExample Newest Innovation from GE Deluxe Dry Air 25 ModelsComparison of DRY AIR 25 Dehumidification Cooling With Resistance HeatTable of Contents Introduction Zoneline System Optional Accessories of the Zoneline SystemChassis Room Cabinet Wall Case2800 Zoneline Features5800 .2Features and Benefits Fan-Cycle Switch SmartFan Fan-Only Setting HIGH/LOWCompressor Restart Delay Electronic Temperature LimitingUp-Front Air Filters Easy Clean Air Discharge AreaConcealed Manual Vent Control Corrosion Protection OptionalAuxiliary Control Switches Cooling Temperature LimitsHeating Temperature Limits Series models only Heat Sentinel Diagnostics Switch Switches Description Left SwitchesSeries Up resistance heat onlyCDC Terminal Location and Typical Wiring Central Desk ControlImportant CDC Comments all series applicable Remote Thermostat Control Field Wiring TerminalResistance Heat Models RAK806 Universal Control Cover LabelHeat Pump Models Feature Heat Pump Electric Heat24V AC Compressor Heater Common GroundRemote Control Low Voltage Wiring For Use With Mechanical 4-Wire Systems OnlyField-Supplied Relay Specifications Relay DesignationBalance Point Heat Pumps and Energy SavingsZoneline Heat Pump Heat Source Logic Heat Pump Operation Zoneline 3800 and 5800 SeriesHeat pump defrost Zoneline 3800 and 5800 Series Heat pump condensateAir Distribution Application CommentsWall Case with Chassis Installed DimensionsRAB71A Wall Case RAB77 Wall CaseWall Case Sub-BaseChoice of wall cases is available for the Zoneline General Wall Case Installation DataWindow, Curtain and Panel Wall Construction Architectural Window Louver InstallationMasonry Wall Construction Brick, Frame, Stucco Shingle ConstructionCase Angles Preparation of the Wall Case for All Types of ConstructionFraming for Wall Case Fastening Wall CaseBrick Veneer and Frame Construction Wall Section Detailed Side View Frame and Brick Veneer Installation Cord set connectedGasket Caulk around Perimeter Wall case all 22-1/4 Where it joins22-1/4 Four sides 22-3/8All four sides where it Power supply42-1/8 27-1/4 13-1/84 ± 1/4 RAB71/7713-3/4 + D Ge.com TOP View RAB71/77 Wall Case RAK204 Series SUB-BASE Installation and Electrical DataCondensate Disposal Systems External Drain. See page 36 for internal drain Wall Case with RAD10 Drain KITInternal Drain. See page 35 for external drain New Ducted Installations Ducted InstallationsReplacements of Existing Ducted Units Ducted Application ConsiderationsRAK6052 Ducted Application AZ2800/3800 SeriesRAK601 High WideDucted Detailed Side Views AZ2800/3800 Series Outdoor Grille Exterior GrillesExterior Architectural Treatments Special Outdoor Grilles 230/208-Volt Line-Cord Connected Units Or 277-Volt Unit Installation Permanently Connected Units230/208-Volt Permanently Connected Units 230/208 Volt Sub-Base and Direct Connected UnitsElectrical Wiring Information 2800/3800/5800 Series Replacement of Existing ChassisEssential Elements Ordering Overview Maximum Connected Load 230/208-Volt Line Cord Connected UnitsVolt Units Cooling Performance Data Heat Pump Performance DataTotal Capacity Btuh Btuh at 80º F D.B. 67º F W.B Indoor Ambient DB Temperature F 100 Latent System Capacity93.00 Outdoor Design Temperature Difference Formula for Calculating Operating Costs Using Above DataInstalled unit capacity Btuh Watts/KW Normal Yearly Operating DataPage Ge.com Typical 5800 Series Schematic Diagram Suggested Bid Form Specifications Suggested Bid Form Specifications Suggested Bid Form Specifications Premium Line 5800 Series Receptacles/Sub-BasesSpecifications RAB71A Complete Accessory ListGeneral Installation Suggestions Ducted Installation Comments Zoneline warrantyReplacement Installations New InstallationsAlphabetical Index Exterior Grille Color SamplesWarm Gray Beige Maple Bittersweet Chocolate GE Company Pub. No -S087 PC48947 Century of quality and innovation