Maximum Connected Load
The maximum connected load of a Zoneline® unit occurs when the unit is in resistance heating operation. The maximum amperage shown in the tables below is the combined total of the resistance heater and the indoor fan motor.
230/208-Volt Line Cord Connected Units
|
|
|
|
|
| Power Connector Kit |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAK3153 |
| RAK3203 |
|
| RAK3303 | |||
|
|
| rak4157 |
| RAK4207 |
|
| RAK4307 | |||
|
| rak204d15p |
| RAK204D20P |
|
| RAK204D30P | ||||
MODEL |
| 230 V |
| 208 V |
| 230 V |
| 208 V | 230 V |
| 208 V |
NUMBER |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
AZ28E07DA* |
| 11.5 |
| 10.5 |
| 15.5 |
| 14.1 | N/A |
| N/A |
AZ28E09DA* |
| 11.5 |
| 10.5 |
| 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ28E12DA* |
| 11.6 |
| 10.6 |
| 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ28E15DA* |
| 11.6 |
| 10.6 |
| 15.6 |
| 14.2 | 22.4 |
| 20.4 |
AZ38H07DA* |
| 11.5 |
| 10.5 |
| 15.5 |
| 14.1 | N/A |
| N/A |
AZ38H09DA* |
| 11.5 |
| 10.5 |
| 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ38H12DA* |
| 11.6 |
| 10.6 |
| 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ38H15DA* |
| 11.6 |
| 10.6 |
| 15.6 |
| 14.2 | 22.4 |
| 20.4 |
AZ58H07DA* |
| 11.5 |
| 10.5 |
| 15.5 |
| 14.1 | N/A |
| N/A |
AZ58H09DA* |
| 11.5 |
| 10.5 |
| 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ58H12DA* |
| 11.6 |
| 10.6 |
| 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ58H15DA* |
| 11.6 |
| 10.6 |
| 15.6 |
| 14.2 | 22.4 |
| 20.4 |
*All versions |
|
|
|
|
|
|
|
|
|
| |
Electric Heat Amps include electric heater and fan motor current draw. |
|
|
|
|
|
| |||||
Values shown in table above are also the total connected loads for units installed with |
|
|
|
| |||||||
RAK204D15P — same as RAK3153 |
|
|
|
|
|
|
|
|
|
| |
RAK204D20P — same as RAK3203 |
|
|
|
|
|
|
|
|
|
| |
RAK204D30P — same as RAK3303 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
| RAK204E15 |
| RAK204E20 |
| RAK204E30 |
|
|
|
| |
|
| RAK5172 |
| RAK5202 |
| RAK5302 |
|
|
|
| |
|
| RAK5157 |
| RAK5207 |
| RAK5307 |
|
|
|
|
|
MODEL |
| 265 V |
| 265 V |
| 265 V |
|
|
|
| |
NUMBER |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
AZ28E07EA |
| 10.2 |
| 13.7 |
| N/A |
|
|
|
| |
AZ28E09EA* |
| 10.2 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ28E12EA* |
| 10.3 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ28E15EA* |
| 10.3 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ38H07EA* |
| 10.2 |
| 13.7 |
| N/A |
|
|
|
| |
AZ38H09EA* |
| 10.2 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ38H12EA* |
| 10.3 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ38H15EA* |
| 10.3 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ58H07EA* |
| 10.2 |
| 13.7 |
| N/A |
|
|
|
| |
AZ58H09EA* |
| 10.2 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ58H12EA* |
| 10.3 |
| 13.7 |
| 19.6 |
|
|
|
|
|
AZ58H15DA* |
| 10.3 |
| 13.7 |
| 19.6 |
|
|
|
|
|
*All versions
Electric Heat Amps include electric heater and fan motor current draw.
44