WALL CASE WITH RAD10 DRAIN KIT
External Drain. See page 36 for internal drain.
SCREWS
“A” “B”
METAL PLASTIC
SEE PAGE 36 NOTE #6
SQUARE DRAIN HOLES
1/2" O.D. 90° ELBOW DRAIN TUBE
NEOPRENE SPONGE GASKET
NOTE: SHADED PARTS AND SCREWS ARE INCLUDED WITH RAD10 DRAIN KIT. USE EITHERTHE 90° ELBOWTUBE OR THE STRAIGHTTUBE DEPENDING UPON THE REQUIREMENTS OFTHE PARTICULAR INSTALLATION.
TYPICAL INSTALLATION
STEEL MOUNTING PLATE
USE TYPE “A” SCREW FOR METAL CASE (RAB71)
AND TYPE “B” SCREW FOR MOLDED CASE (RAB77)
WATER DRAINAGE - Precipitation entering the unit through the outdoor louver may not be removed entirely by the condensate removal system. The base pan flange is designed to allow excess water, either condensate water or precipitation, to flow into the wall case and drain through two drain holes in the rear of the wall case. If there is more water in the wall case than can be drained through these holes it will drain through the three overflow drain holes. These drain holes must not be blocked when mounting or caulking the wall case.
For those installations where water draining from the drain holes is objectionable or where positive drainage is desired, the RAD10 drain kit is available with either a 90° elbow or a 6" straight tube to be used either to connect to a field sup- plied drain line or to allow the water to drip free rather than drain down the surface of the building.
Caulk around perimeter of wall case all four sides where it joins the building.
REAR
GRILLE
90° ELBOW DRAIN TUBE
PROJECTION 3"
BEYOND WALL 4" CASE
CASE ANGLES (FIELD SUPPLIED)
WALL CASE | ROOM |
CABINET
35
NOTE: Drain kit using either the 90° elbow tube or the straight tube may be installed without modification when using RAG60 exterior grille. Drain kit using the 90° elbow tube may be installed without modification when using RAG61 through RAG66 exterior grilles. Modification must be made to the RAG61 through RAG66 exterior grilles when using the straight tube. Modification must be made to the RAG67 grille if using either the 90° elbow tube or the straight tube (see installation instructions with the RAG67 grille).
MIN. 2 SUPPORTS | FLOOR | |