GE 2800 manual Zoneline Features, 5800, .2,  Stage

Page 8

Zoneline® Features

 

 

AZ

AZ

AZ

 

 

2800

800

5800

Enhanced Dehumidification — Dry Air 25

Optional

N/A

N/A

Cooling EER Range (230 Volts/265 Volts)

10.2 - 12.7

10.0 - 12.7

10.2 - 13.0

Heating COP Range (230 Volts/265 Volts)

N/A

.2 - 3.6

.2 - 3.6

Heat Source — Electric Resistance Heat

Standard

Heat Source — Heat Pump With Selectable

 

 

 

 

Full Time or On Demand Simultaneous/

 

 

 

 

Supplemental Resistance Heat

Standard

Standard

Staged Heating

 Stage

 Stage

Universal Heater — UPC*

Standard

Standard

Standard

Unit Controls

Rotary Knobs

Rotary Knobs

Touch Pad

Electronic Temperature Selection

 

 

 

(Slews Up & Down) with Digital Display

Standard

 

 

 

 

Unit Diagnostics

Standard

Highly Featured Microprocessor Controls

Standard

Standard

Standard-Plus

Electric Resistance Heat Lock-Out (above 46°F)

Standard

Standard

Automatic Emergency Heat

Standard

Standard

Heat Pump Defrost System

Reverse Cycle

Reverse Cycle

High Temperature Operation Protection

Standard

Standard

Quick Heat Recovery

Standard

Standard

Temperature Boost

 

Selectable

Selectable

Service Indicator

Temp Display Blinks

Fan Motors — Permanently Lubricated

2

2

2

2-Speed Outdoor Fan

Standard

Standard

Standard

Indoor Fan Speed Selections — HIGH/LOW

Standard

Standard

HIGH/LOW/AUTO

Fan Only Setting — HIGH/LOW

Standard

Standard

Standard

Fan Cycle Switch

“Smart Fan”

“Smart Fan”

“Smart Fan”

Constant-Run Fan

Selectable

Selectable

Selectable

Rotary Compressor

Standard

Standard

Standard

Automatic Compressor Restart Delay

Standard

Standard

Standard

Freeze Sentinel

Standard

Standard

Standard

 

 

 

 

Heat Sentinel

Standard

Standard

Standard

Indoor Coil Frost Control

Standard

Standard

Standard

Transfer Fan Connections

Standard

Standard

Standard

7-Step Electronic Temperature Limiting

Standard

Standard

Standard

Remote Control Capability with Wall Mounted Thermostat

Standard

Standard

Standard

Central Desk Control Capability

Standard

Standard

Standard

Energy Management System Interface with Load Shedding Option

Standard

Standard

Standard

Reversible Indoor Air Louvers 40º/50º

Standard

Standard

Standard

Up-Front Filters

Standard

Standard

Standard

Easy-Clean Air Discharge Area

Standard

Standard

Concealed Manual Vent Control

Standard

Standard

Standard

Ducted Installation Capability

RAK6052

RAK6052

Corrosion Protection (Standard on Dry Air 25)

Optional

Optional

Standard

Internal Condensate Removal (ICR) (Factory Installed Option.

 

 

 

Cannot be used in Corrosion Areas.)

N/A

Optional

Optional

*UPC — Universal Power Cord Connection (See pages 42 and 55).

265-volt units must be connected in a manner to meet National Electrical Code and all local codes.

Image 8
Contents GE Zoneline packaged terminal air conditioners ALL Units Require Power Connection KIT Quick ReferenceExample Power Connection KitsZoneline Chassis Nomenclature Deluxe Dry Air 25 Models Newest Innovation from GEComparison of DRY AIR 25 Dehumidification Cooling With Resistance HeatTable of Contents Introduction Optional Accessories of the Zoneline System Zoneline SystemChassis Room Cabinet Wall CaseZoneline Features 28005800 .2Features and Benefits Fan-Only Setting HIGH/LOW Fan-Cycle Switch SmartFanCompressor Restart Delay Electronic Temperature LimitingEasy Clean Air Discharge Area Up-Front Air FiltersConcealed Manual Vent Control Corrosion Protection OptionalHeating Temperature Limits Auxiliary Control SwitchesCooling Temperature Limits Switches Description Left Switches Series models only Heat Sentinel Diagnostics SwitchSeries Up resistance heat onlyImportant CDC Comments all series applicable CDC Terminal Location and Typical WiringCentral Desk Control Field Wiring Terminal Remote Thermostat ControlResistance Heat Models RAK806 Universal Control Cover LabelFeature Heat Pump Electric Heat Heat Pump Models24V AC Compressor Heater Common GroundFor Use With Mechanical 4-Wire Systems Only Remote Control Low Voltage WiringField-Supplied Relay Specifications Relay DesignationHeat Pumps and Energy Savings Balance PointHeat Pump Operation Zoneline 3800 and 5800 Series Zoneline Heat Pump Heat Source LogicHeat pump defrost Zoneline 3800 and 5800 Series Heat pump condensateApplication Comments Air DistributionDimensions Wall Case with Chassis InstalledRAB71A Wall Case RAB77 Wall CaseChoice of wall cases is available for the Zoneline Wall CaseSub-Base Wall Case Installation Data GeneralArchitectural Window Louver Installation Window, Curtain and Panel Wall ConstructionMasonry Wall Construction Brick, Frame, Stucco Shingle ConstructionPreparation of the Wall Case for All Types of Construction Case AnglesBrick Veneer and Frame Construction Framing for Wall CaseFastening Wall Case Frame and Brick Veneer Installation Cord set connected Wall Section Detailed Side View22-1/4 Where it joins Gasket Caulk around Perimeter Wall case all22-1/4 Four sides 22-3/8Power supply All four sides where it42-1/8 27-1/4 13-1/813-3/4 + D 4 ± 1/4RAB71/77 Ge.com TOP View RAK204 Series SUB-BASE Installation and Electrical Data RAB71/77 Wall CaseCondensate Disposal Systems Wall Case with RAD10 Drain KIT External Drain. See page 36 for internal drainInternal Drain. See page 35 for external drain Ducted Installations New Ducted InstallationsReplacements of Existing Ducted Units Ducted Application ConsiderationsDucted Application AZ2800/3800 Series RAK6052RAK601 High WideDucted Detailed Side Views AZ2800/3800 Series Exterior Grilles Outdoor GrilleExterior Architectural Treatments Special Outdoor Grilles Or 277-Volt Unit Installation Permanently Connected Units 230/208-Volt Line-Cord Connected Units230/208-Volt Permanently Connected Units 230/208 Volt Sub-Base and Direct Connected UnitsEssential Elements Ordering Overview Electrical Wiring Information 2800/3800/5800 SeriesReplacement of Existing Chassis Volt Units Maximum Connected Load230/208-Volt Line Cord Connected Units Total Capacity Btuh Btuh at 80º F D.B. 67º F W.B Cooling Performance DataHeat Pump Performance Data 93.00 Indoor Ambient DB Temperature F 100Latent System Capacity Formula for Calculating Operating Costs Using Above Data Outdoor Design Temperature DifferenceInstalled unit capacity Btuh Watts/KW Normal Yearly Operating DataPage Ge.com Typical 5800 Series Schematic Diagram Suggested Bid Form Specifications Suggested Bid Form Specifications Suggested Bid Form Specifications Receptacles/Sub-Bases Premium Line 5800 SeriesSpecifications Complete Accessory List RAB71AGeneral Installation Suggestions Zoneline warranty Ducted Installation CommentsReplacement Installations New InstallationsWarm Gray Beige Maple Bittersweet Chocolate Alphabetical IndexExterior Grille Color Samples Century of quality and innovation GE Company Pub. No -S087 PC48947