APC ACPA4000 manual Inspecting the Equipment, Storing the Equipment Before Installation, Safety

Page 11
Safety

Safety

Warning: Use the equipment on a flat surface.

Do not obstruct the equipment air outlets.

For indoor use only.

Do not attempt to service the equipment except to clean and replace the air filters. The equipment contains no other user-serviceable parts.

Do not place the rear of the equipment closer than 203 mm (8 in) to any wall or obstacle.

Do not install the equipment where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.

Do not place this equipment on its side. If the equipment has been tipped, place it upright on a flat, solid surface and keep it in this position for a minimum of 12 hours before operating.

Electrical Hazard: Connect the equipment to a 3-wire AC outlet (two poles plus a ground). The receptacle must be connected to a dedicated, properly grounded 115 volt 60Hz branch circuit rated for 20 amp main protection (fuses/circuit breaker). Connection to any other power source may result in a shock hazard or damage to the equipment.

Use the equipment with the supplied power cord only.

Do not use an extension cord.

Inspecting the Equipment

Your equipment has been tested and inspected for quality assurance before shipment. To ensure that the equipment has not been damaged during transit, carefully inspect both the exterior and interior packaging of the equipment immediately upon receipt.

Verify that all parts ordered were received as specified. See “Inventory” on page 4.

Filing a claim

If damage is identified on receipt of the equipment, note the damage on the bill of lading and file a damage claim with the shipping company. Contact APC for information on filing a claim with the shipping company. The shipping claim must be filed at the receiving end of the delivery.

Note: In case of shipping damage, do not operate the equipment. Keep all packaging for inspection by the shipper and contact APC customer support at one of the numbers listed on the back cover of this manual.

Storing the Equipment Before Installation

Caution: Leaving the equipment uncovered and exposed to the elements can cause damage and voids the factory warranty.

NetworkAIR ACPA4000

3

Image 11
Contents NetworkAIR Portable Air Conditioning Unit ACPA4000Installation, Operation, and Maintenance Page American Power Conversion Legal Disclaimer Page Contents InstallationGeneral Information Operation Maintenance and Troubleshooting Page About the NetworkAIR ACPA4000 General InformationOverview Manual updatesCross-referencesymbol used in this manual Safety symbols that may be used in this manualFiling a claim Storing the Equipment Before InstallationInspecting the Equipment SafetyThe equipment ships with the items shown below Tools RequiredInventory Rear view Component IdentificationFront view Shipping Weight Dimensions and WeightsDimensions are shown in mm in Net WeightLock the rolling casters InstallationWhere to locate the equipment Assemble the ceiling adapter Intake and Exhaust VentsHose connections NetworkAIR ACPA4000 Install the adapter in a drop ceilingAssemble the ducts Attach the drain line. Attach Drain LineConnect the fitting to the drain line Temperature/humidity sensor AccessoriesOutput relays Relays and ContactsOverview To connect an input contact Input contactsTo connect an output relay How to apply power to the equipment Start-UpStart-upchecklist Display interface identification OperationOverview Scrolling status screens How to Use the InterfaceTurn on the equipment Date 18-Jun-2007 Time Main menu screenNavigating the interface Date 18-Jun-2007 TimeTurn off the equipment Change settingsPassword entry Default schedule Set Environmental ControlsMode Operating schedulesSchedule 1 of Schedule On/OffSet the alarm delay Set Up AlarmsTemperature and humidity alarms Display interface options Set Up the DisplayPassword and time-out Set the date and timePath Main Menu Setup Factory Defaults Device settingsResetting to default settings Path Main Menu Setup System DeviceHow to download firmware User outputs Set Up Contacts and RelaysInput contacts User input contactsSystem and environmental status screens Checking Equipment StatusDefault schedule status Scrolling status screensManufacturer data Viewing alarm statusWarning or alarm LED Responding to AlarmsSilencing the alarm beeper Silence Active AlarmResolving alarm conditions Active alarm screenAlarm and event log Action Required Alarm messagesAlarm Message Remote temperature Alarm MessageAction Required Monitoring information Display Interface Reference ChartsSetup Scrolling status screensControl Environment Programmable settingsSetup StatusSystem SetupReplace the air filter Maintenance and TroubleshootingMaintenance Update the main control board firmware Clean the condenser filter and test the LCDI plugClean the cabinet Corrective action TroubleshootingProblem Possible causeExclusions One-YearFactory WarrantyTerms of warranty Non-transferablewarrantyWarranty claims Parts Warranty ProceduresClaims Component Type SpecificationsElectrical PhysicalPage 03/2008 990-0412DAPC Worldwide Customer Support 990-0412D