Change settings

Change settings

To change a setting, use the up or down arrow keys to move the selector arrow to the setting and press the ENTER key.

List of choices. If the setting is a list of choices, an input arrow is displayed next to the setting. Press the up or down arrow key to make your selection. Press the ENTER keys to save the setting and exit from input mode. Press the ESC key to exit without saving.

Numbers or text fields. If the setting is a number or text field, use the arrow keys to select the value for the first character and press the ENTER key to move to the next character position. Repeat this procedure to select and set each character. After the last character is set, press the ENTER key to save the setting and exit from input mode. Press the ESC key to exit without saving.

Password entry

To change any setting, you are prompted to enter your password. The default password is APC. To enter each character or digit of the password, use the up and down arrow keys to scroll to the character and press the ENTER key. The cursor moves to the next position. After entering the last character of the password, press the ENTER key again to submit the password.

Note: Passwords are case-sensitive.

Turn off the equipment

Path: Main Menu > On/Off.

To shut off the equipment, select the On/Off option on the main menu and change the setting to Off.

Note: Change the setting to Off to shut down the cool mode and the blower fan. The display continues to receive power.

NetworkAIR ACPA4000

19

Image 27
Contents ACPA4000 Installation, Operation, and MaintenanceNetworkAIR Portable Air Conditioning Unit Page American Power Conversion Legal Disclaimer Page Installation General InformationContents Operation Maintenance and Troubleshooting Page About the NetworkAIR ACPA4000 General InformationOverview Manual updatesCross-referencesymbol used in this manual Safety symbols that may be used in this manualFiling a claim Storing the Equipment Before InstallationInspecting the Equipment SafetyTools Required InventoryThe equipment ships with the items shown below Component Identification Front viewRear view Shipping Weight Dimensions and WeightsDimensions are shown in mm in Net WeightInstallation Where to locate the equipmentLock the rolling casters Intake and Exhaust Vents Hose connectionsAssemble the ceiling adapter NetworkAIR ACPA4000 Install the adapter in a drop ceilingAssemble the ducts Drain Line Connect the fitting to the drain lineAttach the drain line. Attach Temperature/humidity sensor AccessoriesRelays and Contacts OverviewOutput relays Input contacts To connect an output relayTo connect an input contact Start-Up Start-upchecklistHow to apply power to the equipment Operation OverviewDisplay interface identification How to Use the Interface Turn on the equipmentScrolling status screens Date 18-Jun-2007 Time Main menu screenNavigating the interface Date 18-Jun-2007 TimeChange settings Password entryTurn off the equipment Default schedule Set Environmental ControlsMode Operating schedulesSchedule 1 of Schedule On/OffSet Up Alarms Temperature and humidity alarmsSet the alarm delay Display interface options Set Up the DisplayPassword and time-out Set the date and timePath Main Menu Setup Factory Defaults Device settingsResetting to default settings Path Main Menu Setup System DeviceHow to download firmware User outputs Set Up Contacts and RelaysInput contacts User input contactsSystem and environmental status screens Checking Equipment StatusDefault schedule status Scrolling status screensManufacturer data Viewing alarm statusWarning or alarm LED Responding to AlarmsSilencing the alarm beeper Silence Active AlarmActive alarm screen Alarm and event logResolving alarm conditions Alarm messages Alarm MessageAction Required Alarm Message Action RequiredRemote temperature Monitoring information Display Interface Reference ChartsSetup Scrolling status screensControl Environment Programmable settingsSetup StatusSystem SetupMaintenance and Troubleshooting MaintenanceReplace the air filter Clean the condenser filter and test the LCDI plug Clean the cabinetUpdate the main control board firmware Corrective action TroubleshootingProblem Possible causeExclusions One-YearFactory WarrantyTerms of warranty Non-transferablewarrantyWarranty claims Warranty Procedures ClaimsParts Component Type SpecificationsElectrical PhysicalPage 03/2008 990-0412DAPC Worldwide Customer Support 990-0412D