APC ACPA4000 manual Operation, Overview, Display interface identification

Page 24
Operation

Operation

Overview

Display interface identification

System

On

Check

Log

Minor

Alarm

Major

Alarm

ESC

 

?

na0137a

 

Item

Function

 

 

Major Alarm LED

When red, a major alarm condition exists.

 

 

Minor Alarm LED

When orange, a minor alarm condition exists.

 

 

Check Log LED

When orange, at least one new alarm or warning event has

 

occurred.

 

 

System On LED

When green, the evaporator blower is running.

 

 

Liquid Crystal

Shows alarms, status data, instructional help, and setup

Display (LCD)

items.

 

 

Up and down arrow

Navigate the display menus.

keys

 

 

 

ESC key

Return to previous screen.

 

 

Enter key

Open menu items and input changes to system settings.

 

 

Help key

Launches context-sensitive help. Press this key for

 

information about each item on the screen and for

 

instructions on how to perform tasks.

 

 

16

NetworkAIR ACPA4000

Image 24
Contents ACPA4000 Installation, Operation, and MaintenanceNetworkAIR Portable Air Conditioning Unit Page American Power Conversion Legal Disclaimer Page Installation General InformationContents Operation Maintenance and Troubleshooting Page General Information OverviewManual updates About the NetworkAIR ACPA4000Safety symbols that may be used in this manual Cross-referencesymbol used in this manualStoring the Equipment Before Installation Inspecting the EquipmentSafety Filing a claimTools Required InventoryThe equipment ships with the items shown below Component Identification Front viewRear view Dimensions and Weights Dimensions are shown in mm inNet Weight Shipping WeightInstallation Where to locate the equipmentLock the rolling casters Intake and Exhaust Vents Hose connectionsAssemble the ceiling adapter Install the adapter in a drop ceiling NetworkAIR ACPA4000Assemble the ducts Drain Line Connect the fitting to the drain lineAttach the drain line. Attach Accessories Temperature/humidity sensorRelays and Contacts OverviewOutput relays Input contacts To connect an output relayTo connect an input contact Start-Up Start-upchecklistHow to apply power to the equipment Operation OverviewDisplay interface identification How to Use the Interface Turn on the equipmentScrolling status screens Main menu screen Navigating the interfaceDate 18-Jun-2007 Time Date 18-Jun-2007 TimeChange settings Password entryTurn off the equipment Set Environmental Controls Default scheduleOperating schedules Schedule 1 ofSchedule On/Off ModeSet Up Alarms Temperature and humidity alarmsSet the alarm delay Set Up the Display Password and time-outSet the date and time Display interface optionsDevice settings Resetting to default settingsPath Main Menu Setup System Device Path Main Menu Setup Factory DefaultsHow to download firmware Set Up Contacts and Relays Input contactsUser input contacts User outputsChecking Equipment Status Default schedule statusScrolling status screens System and environmental status screensViewing alarm status Manufacturer dataResponding to Alarms Silencing the alarm beeperSilence Active Alarm Warning or alarm LEDActive alarm screen Alarm and event logResolving alarm conditions Alarm messages Alarm MessageAction Required Alarm Message Action RequiredRemote temperature Display Interface Reference Charts SetupScrolling status screens Monitoring informationProgrammable settings SetupStatus Control EnvironmentSetup SystemMaintenance and Troubleshooting MaintenanceReplace the air filter Clean the condenser filter and test the LCDI plug Clean the cabinetUpdate the main control board firmware Troubleshooting ProblemPossible cause Corrective actionOne-YearFactory Warranty Terms of warrantyNon-transferablewarranty ExclusionsWarranty claims Warranty Procedures ClaimsParts Specifications ElectricalPhysical Component TypePage 990-0412D APC Worldwide Customer Support990-0412D 03/2008