APC ACPA4000 manual Device settings, Resetting to default settings, User-definedproduct data

Page 32
Device settings

Device settings

Path: Main Menu > Setup > System > Device.

Temperature Units. Set the units of measure for temperature readings and settings.

Start Delay. Set the delay between equipment start and when cooling begins.

This delay is in addition to the start-up delay described in “Turn on the equipment” on page 17.

Resetting to default settings

Path: Main Menu > Setup > Factory Defaults.

Reset to factory defaults. Resetting to factory defaults returns display options to their factory settings. It does not affect the mode, setpoints, deadband, time, date, run hour meters, or password settings.

User-defined product data

Path: Main Menu > Setup > Product Data.

The Product Data menu option provides a place to store information about the display interface. Enter the equipment name, the physical address of the equipment, and emergency or service contact information.

24

NetworkAIR ACPA4000

Image 32
Contents NetworkAIR Portable Air Conditioning Unit ACPA4000Installation, Operation, and Maintenance Page American Power Conversion Legal Disclaimer Page Contents InstallationGeneral Information Operation Maintenance and Troubleshooting Page General Information OverviewManual updates About the NetworkAIR ACPA4000Safety symbols that may be used in this manual Cross-referencesymbol used in this manualStoring the Equipment Before Installation Inspecting the EquipmentSafety Filing a claimThe equipment ships with the items shown below Tools RequiredInventory Rear view Component IdentificationFront view Dimensions and Weights Dimensions are shown in mm inNet Weight Shipping WeightLock the rolling casters InstallationWhere to locate the equipment Assemble the ceiling adapter Intake and Exhaust VentsHose connections Install the adapter in a drop ceiling NetworkAIR ACPA4000Assemble the ducts Attach the drain line. Attach Drain LineConnect the fitting to the drain line Accessories Temperature/humidity sensorOutput relays Relays and ContactsOverview To connect an input contact Input contactsTo connect an output relay How to apply power to the equipment Start-UpStart-upchecklist Display interface identification OperationOverview Scrolling status screens How to Use the InterfaceTurn on the equipment Main menu screen Navigating the interfaceDate 18-Jun-2007 Time Date 18-Jun-2007 TimeTurn off the equipment Change settingsPassword entry Set Environmental Controls Default scheduleOperating schedules Schedule 1 ofSchedule On/Off ModeSet the alarm delay Set Up AlarmsTemperature and humidity alarms Set Up the Display Password and time-outSet the date and time Display interface optionsDevice settings Resetting to default settingsPath Main Menu Setup System Device Path Main Menu Setup Factory DefaultsHow to download firmware Set Up Contacts and Relays Input contactsUser input contacts User outputsChecking Equipment Status Default schedule statusScrolling status screens System and environmental status screensViewing alarm status Manufacturer dataResponding to Alarms Silencing the alarm beeperSilence Active Alarm Warning or alarm LEDResolving alarm conditions Active alarm screenAlarm and event log Action Required Alarm messagesAlarm Message Remote temperature Alarm MessageAction Required Display Interface Reference Charts SetupScrolling status screens Monitoring informationProgrammable settings SetupStatus Control EnvironmentSetup SystemReplace the air filter Maintenance and TroubleshootingMaintenance Update the main control board firmware Clean the condenser filter and test the LCDI plugClean the cabinet Troubleshooting ProblemPossible cause Corrective actionOne-YearFactory Warranty Terms of warrantyNon-transferablewarranty ExclusionsWarranty claims Parts Warranty ProceduresClaims Specifications ElectricalPhysical Component TypePage 990-0412D APC Worldwide Customer Support990-0412D 03/2008