Set Up the Display

Set Up the Display

The display interface provides access to the data and settings necessary to operate the equipment. Use the display interface to control data displayed, configure security features, and update and upgrade the firmware that controls the equipment.

Password and time-out

Path: Main Menu > Setup > System > System Password.

Note: The default password is APC. See “Password entry” on page 19 for information on how to enter the password.

Change the password:

1.Move the selector arrow to the password option and press the ENTER key.

2.Enter the current password to return to the password setup screen.

3.Press the ENTER key to change the password and enter a new password string (up to eight characters).

4.Press the ENTER key to confirm.

Password and menu time-out.The time-out is the adjustable period allowed for changing settings. Once the time period has elapsed, the display interface returns to the scrolling status screens and you must enter the password again.

Invalidate password. Use the Invalidate NOW option to override the password time-out and require password entry again.

Set the date and time

Path: Main Menu > Setup > System > Date/Time.

Setting the date. The date is displayed on some status screens and is also used in the alarm/event log to date-stamp system events. Enter the day, month, and year and press the ESC key to exit the input mode.

Setting the time. The time is displayed on some status screens and is also used in the alarm/event log to time-stamp system events. Enter the correct time and press the ENTER key.

Daylight saving time adjust. Set the DST Adjust to On or Off. It automatically changes the clock settings on the appropriate dates to account for daylight saving time.

Display interface options

Path: Main Menu > Setup > System > Local Interface.

LCD contrast. Adjust the visibility of the screen text. Lower numbered settings provide darker text and higher numbers provide lighter text. Settings range from 0–7.

Key Click. Enable an audible tone every time a key is pressed on the display interface.

Beeper Volume. Adjust the volume of the alarm tone and key clicks for the audible tone that sounds every time a key is pressed on the display interface. Options are low, medium, high, and off.

NetworkAIR ACPA4000

23

Image 31
Contents Installation, Operation, and Maintenance ACPA4000NetworkAIR Portable Air Conditioning Unit Page American Power Conversion Legal Disclaimer Page General Information InstallationContents Operation Maintenance and Troubleshooting Page About the NetworkAIR ACPA4000 General InformationOverview Manual updatesCross-referencesymbol used in this manual Safety symbols that may be used in this manualFiling a claim Storing the Equipment Before InstallationInspecting the Equipment SafetyInventory Tools RequiredThe equipment ships with the items shown below Front view Component IdentificationRear view Shipping Weight Dimensions and WeightsDimensions are shown in mm in Net WeightWhere to locate the equipment InstallationLock the rolling casters Hose connections Intake and Exhaust VentsAssemble the ceiling adapter NetworkAIR ACPA4000 Install the adapter in a drop ceilingAssemble the ducts Connect the fitting to the drain line Drain LineAttach the drain line. Attach Temperature/humidity sensor AccessoriesOverview Relays and ContactsOutput relays To connect an output relay Input contactsTo connect an input contact Start-upchecklist Start-UpHow to apply power to the equipment Overview OperationDisplay interface identification Turn on the equipment How to Use the InterfaceScrolling status screens Date 18-Jun-2007 Time Main menu screenNavigating the interface Date 18-Jun-2007 TimePassword entry Change settingsTurn off the equipment Default schedule Set Environmental ControlsMode Operating schedulesSchedule 1 of Schedule On/OffTemperature and humidity alarms Set Up AlarmsSet the alarm delay Display interface options Set Up the DisplayPassword and time-out Set the date and timePath Main Menu Setup Factory Defaults Device settingsResetting to default settings Path Main Menu Setup System DeviceHow to download firmware User outputs Set Up Contacts and RelaysInput contacts User input contactsSystem and environmental status screens Checking Equipment StatusDefault schedule status Scrolling status screensManufacturer data Viewing alarm statusWarning or alarm LED Responding to AlarmsSilencing the alarm beeper Silence Active AlarmAlarm and event log Active alarm screenResolving alarm conditions Alarm Message Alarm messagesAction Required Action Required Alarm MessageRemote temperature Monitoring information Display Interface Reference ChartsSetup Scrolling status screensControl Environment Programmable settingsSetup StatusSystem SetupMaintenance Maintenance and TroubleshootingReplace the air filter Clean the cabinet Clean the condenser filter and test the LCDI plugUpdate the main control board firmware Corrective action TroubleshootingProblem Possible causeExclusions One-YearFactory WarrantyTerms of warranty Non-transferablewarrantyWarranty claims Claims Warranty ProceduresParts Component Type SpecificationsElectrical PhysicalPage 03/2008 990-0412DAPC Worldwide Customer Support 990-0412D