Control Branch

Access Disabled

The remote modem’s Access from Remote configuration is disabled.

Password Invalid

The local and remote modems’ passwords do not match. Correct the

 

problem and attempt another download from the local modem. If this

 

fails, contact your service representative.

No Circuit

There is no connection between the local and remote modem.

After successful establishment of a Remote Cloning Download session, the following screens appear.

RemClone Status

Initializing

F1 F2 F3

RemClone Status

Bank1:xxxx/yyyy

F1 F2 F3

As data banks are transferred, the local and remote LCD’s bottom line displays the status of the download process, and the number of records sent versus the total number of records for that bank.

For Single download applications, if the download is successful, the local modem displays Remote Clone OK and the remote modem displays Frmware Upgrade. If the download took place over the dial network, the modems disconnect when the download is complete.

If the Single download is unsuccessful, RemClone Failed appears on the LCD’s top line. Attempt another download from the local modem. If this fails, contact your service representative.

VF Thresholds Update

The VF Thresholds Update function allows you to set the thresholds that determine the Health and Status alarm conditions for the VF parameters. The following thresholds may be edited: RSL High, RSL Low, Sig/Noise, NonLinear, Retrains/15min, Signal Quality, Near Echo, and Far Echo. (For Health and Status alarm conditions, refer to Table 4-1 in the Device Health and Status (DeviceHS) section of Chapter 4, Status Branch.)

To access VF Thresh Update from the Control branch, make the following selections:

Control:<

VF_Thresh_Update

F1 F2 F3

3910-A2-GN32-40

September 1998

7-13

Page 133
Image 133
Digicom 3910, 3911 operation manual VF Thresholds Update, Access Disabled, Password Invalid, No Circuit